Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Electronics Quality》 2008-12
Add to Favorite Get Latest Update

Circuit Fault Diagnosis Based on Optical Fibers-based Smart Structures

Yang Ming1Zeng Jie2 1.The PLA Research Center of Communication Measure and Test Technology Jiangsu NanJing 2100072.The Aeronautical Science Key Laboratory for Smart Materials and Structures,NUAA,Jiangsu Nanjing 210016  
The paper introduces a method of circuit fault diagnosis,Based on the IC thermal mode,an IC operating temperature standard thermal mode is gotten by measuring the components temperature with the optical fibers smart structures,which stuck on the board closely.By temperature of troubled component and comparison with the standard mode,with the member function of fuzzy to tell fault component apart.The experiment indicates the feasibility of the method and the expansibility of optical fibers smart structures for circuit fault diagnosis.
【CateGory Index】: TN41
Download(CAJ format) Download(PDF format)