Fabrication and Characterization of Nanometer-sized Gold Electrode and Its Applications to Heterogeneous Catalytic Reactoins

Cai Chengxin, Ju Huangxian, Chen Hongyuan (Department of Chemistry, Nanjing University, Nanjing 210093)  
The nanometer-sized gold electrode is fabricated. The surface of the electrode is observed by X-ray photoelectron spectrum(XPS) and scan electron microscopy (SEM). The voltammetric characteristics of the electrode are studied by cyclic voltammetry and chronoamperometry, respectively. Simultaneous immobilization of glucose oxidase (GOD) and Fe(CN)6 3- as an electron mediator in polypyrrole (PPy) films was successfully accomplished at ultramicroband gold electrode to provide a simple biosensor capable of detecting glucose in a wide concentration range without oxygen as mediator in solution. The experimental results show that the relationship between the steady-state current of glucose at GOD/Fe (CN)6 3-/PPy electrode and the concentration of glucose is characterized by Michealis-Menten equation.
【Fund】: 国家自然科学基金;; 青年基金
【CateGory Index】: O643.3
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 1 Hits
1 XIE You-bin,LIU Hong-ying,DENG Xiang-hui,KAN Xian-wen,FANG Bin(College of Chemistry and Material Science,Anhui Normal University,Wuhu 241000,China);Preparation for Ferrocene Carboxylic Acid Modified Goldelectrode and Electrocatalytical Oxidation of Ascorbic Acid[J];Journal of Anhui Normal University(Natural Science);2006-03
【Citations】
Chinese Journal Full-text Database 2 Hits
1 JU Huang-xian, CHEN Hong-yuan, GAO Hong(H. Kao) (Department of Chemistry, Nanjing University, Nanjing, 210008);Investigation on Microelectrodes (Ⅹ)--The Steady-State Differential Voltammetry on Microdisc Electrode[J];Chemical Research In Chinese Universities;1992-05
2 Peng, Tu-Zhi Wang, Guo-Shun Shen, Bao-En(Department of Chemistry, Hangzhou University, Hangzhou, 310028) Liu, Guo-Qing Cao, Yu-Ping(Department of Pharmacology, China Pharmaceutical University, Nanjing, 210009);Electrochemical Activation of Carbon Fiber Microelectrodes for in vivo Determination of Neurotransmitters and Ascorbic Acid[J];Acta Chimica Sinica;1993-08
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 Peng Tuzhi Yang Liju Hong Jiaqiong(Dept. of Chemistry, Hangzhou Univ. ) (Zhejaing Hospital. );In Vivo Voltammetric Determination of Neurotransmitters with Carbon Fiber Electrodes Modified with Nafion[J];Journal of Transcluction Technology;1996-01
2 SUN Deng-ining(Department of Chemutry, Huai6ei Coal Indastry Teachers College, Huaibei 235000);Separation of the Anodic Peaks of Ascorbic Acid and Dopamine at Poly(fuchsin basic) Modified Electrodes.[J];JOURNAL OF HUAIBEI INDUSTRY TEACHERS COLLEGE (NATURAL SCIENCES EDITION);1999-04
3 He Pingang, Yu Yanling, Xu Chun, Fang Yuzhi (Department of Chemistry, East China Normal University, Shanghai 200062 );Selective Determination of Serotonin With Electrochemically Pretreated Carbon Fibre Microelectrode Modified With Lipoic Acid[J];Chinese Journal of Analytieal Chemistry;1997-01
4 Guo Yingkai, Shao Mengxin (Department of Environment Engineering, Professional College of Tianjin, Tianjin 300402) Zhang Chunxu (Department of Chemistry, Nankai University, Tianjin 300071) Zhao Jingkui (Department of Medical Detection, Medical University;Determination of Neurotransmitter in Body Fluid With Voltammetry at Bevelled Carbon Fiber Array Electrodes[J];Chinese Journal of Analytieal Chemistry;1997-05
5 Zhang Yonghua and Wang Erkang (Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022);Electroanalytical Chemistry[J];Analytical Laboratory;1993-05
6 YANG Li-Ju, PENG Tu-Zhi~ (Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou 310028, China);Construction of Montmorillonite-modified Carbon Fiber Electrode and ItsIn-vivo Detection of Neurotransmitter[J];Chemical Research In Chinese Universities;2001-02
7 PENG Tu-Zhi;YANG Li-Ju;LI Hui-Ping;WANG Guo-Shun;HONG Jia-Qiong(Department of Chemistry.Hangzhou University,Hangzhou,310028)(Zhejiang Hospital);Determination of the Neurotransmitter in the Brain Using Composite Polymer Microelectrodes[J];CHEMICAL RESEARCH IN CHINESE UNIVERSITIES;1995-12
8 YANG Wei; ZHANG Liansheng(Department of Chemistry, Heilongjiang University)WANG Yuqin; SUN Ting; SHING Ming(Department of Petroleum, Heilongjiang Commercia College);Study on Synthesis of Interpenetrating Polymer Networks Composed of Polyacrylamide and Na-Bentonite In W/O Emulsion[J];JOURNAL OF NATURAL SCIENCE OF HEILONGJIANG UNIVERSITY;1995-01
9 Jin, Bao-Kang Zhang, Zu-Xun(Department of Chemistry, Nanjing University, Nanjing, 210093);The Theory of Linear Sweep and Its Derivative Voltammetry for Quasi-steady-state Reversible Wave at Ultramicrodisk Electrode[J];Acta Chimica Sinica;1995-05
10 YANG Hang sheng, PENG Tu zhi, SHEN Bao en (Department of Chemistry, Zhejiang University, Hangzhou 310028, China);Thin-layer spectroelectrochemical investigation of dopamine oxidation on carbon fiber electrodes.[J];Journal of Zhejiang University(Sciences Edition);2001-03
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 Gan Lin Chen Yali Lu Zuhong(National Laboratory of Molecular and Biomolecular electronicsSoutheast University, Nanjing. 210096);Fabrication and Applications of Biochips[J];Journal of Transcluction Technology;1998-02
2 Dong Xiandui; Lu Juntao; Cha Chuanxin(Depertment of Chemistry,Wuhan University, Wuhan 430072);Self Assembly via Layer by Layer Surface Reaction on Gold Electrodes and the Electrochcmical Characterization[J];ELECTROCHEMISTRY;1995-01
3 Jia NengqinSun ChuijueGao LingZhang Zongrang* (Dept.of Chem., Shanghai Teachers Univ.,Shanghai 200234) Zhu JiangzhongZhang Guoxiong (Shanghai Inst.of Metallurgy,Chinese Acad.of Sci.,Shanghai 20050);Study on the Microband Array Electrode_based Glucose Microsensor[J];ELECTROCHEMISTRY;1999-02
4 Ju Huangxian~*, Chen Hongyuan, Gao Hong(H.Kao) (Department of Chemistry, Nanjing University, Nanjing 210008);Characteristics and Applications of Microelectrode Array[J];Chinese Journal of Analytical Chemistry;1992-01
5 Wang Meiquan, Fang Huiqun, Shi Jian, Chen Hongyuan (Department of Chemistry, Nanjing University, Nanjing 210008);The Preparation and Application of Functionalized Polypyrrole Modified Electrode[J];Chinese Journal of Analytical Chemistry;1993-04
6 Li Jinghong; Cheng Guangjin; Dong Shaojun (Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry,Chinese Academy of Sciences, Changchun 130022);Applications of Self -Assembled Monolayers in Electroanalytical Chemistry[J];Chinese Journal of Analytieal Chemistry;1996-09
7 Tian Chengyun, Cao Dajun, Zhang Zongrang (Department of Chemistry, Shanghai Normal University, Shanghai 200234) Zhu Jianzhong, Zhang Guoxiong (State Key-Laboratory of Transducer Technology, Shanghai Institute of Metallurgy, Chinese Academy of Sciences, S;A Polypyrrole-modified Planar Glucose Sensor[J];Chinese Journal of Analytieal Chemistry;1998-07
8 Jia Nengqin; Zhu Yan; Zhang Zongrang (Department of Chemistry, Shanghai Teachers University, Shanghai 200234) Zhu Jiangzhong; Zhang Guoxiong (Shanghai Institute of Metallurgy, Chinese Academy of Sciences, Shanghai 200050);A Chamber-type Microchip-based Microchip-based Biosensor[J];Chinese Journal of Analytieal Chemistry;2000-07
9 Lou Yin-hua, Zheng Dong-sheng, Zhang Rong-kun(Deparment of Chemistry, Xiamen University, Xiamen, 361005)Wang Jin (The Nanjing Medical College);Application and Current Response of Electrochemical and Immobile Polypyrrole Cholesterol Oxidase Electrode[J];Chemical Research In Chinese Universities;1991-10
10 PANG Dai Wen, YAN Wei (Department of Chemistry, Wuhan University, Wuhan 430072, China);Genosensors and Strategies for the Research and Development[J];Chemical Research In Chinese Universities;2001-03
【Secondary References】
Chinese Journal Full-text Database 3 Hits
1 ZHANG Wei,ZHANG Wen-zhi,TAO Hai-sheng,FANG Bin~* (College of Chemistry and Materials Science,Anhui Normal University,Wuhu 241000,China);A Selective Determination Foruric At Ferrocene/β-Cyclodextrin/Carb On Nanotubes Modified Electrode[J];Journal of Anhui Normal University(Natural Science);2006-05
2 JIANG Xi-ming,FANG Zhao,TAO Hai-sheng(College of Chemistry and Materials Science,Anhui Normal University,Wuhu 241000,China);Determination of Ascobic Acid at the L-cysteine Self-Assembled Monolayers Modified Gold Electrode[J];Journal of Anhui Normal University(Natural Science);2006-05
3 WANG Cong(1,2),WANG Guang-feng1,CHEN Dao-lei1,FANG Bin1 (1.School of Chemistry and Materials Science,Anhui Normal University, Wuhu,Anhui 241000,China;2.Lab of Photoelectric Chemistry,Department of Chemistry-Biology,Suzhou College,Suzhou,Anhui 234000,China);Electrocatalysis of Rutin at Aminylferrocene/Nanogold Modified Electrode[J];Journal of Anhui Normal University(Natural Science);2007-01
【Secondary Citations】
Chinese Journal Full-text Database 2 Hits
1 Chen Hong-yuan, Ju Huang-xian (Department of Chemistry, Nanjing University, Nanjing, 210008);Investigation on Carbon Fiber Microelectrodes (Ⅴ)——The Kinetics of Ferrocene and Its Derivatives on Carbon Fiber Ultramicroelectrodes[J];Chemical Research In Chinese Universities;1991-11
2 Dong Shaojun He Jun (Changchun Institute of Applied Chemistry,Academia Sinica);DECONVOLUTION VOLTAMMETRY AND AC VOLTAMMETRY AT DISK MICROELECTRODE[J];Chinese Journal of Applied Chemistry;1988-05
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved