On Enhancement of Anti-jamming Ability of High-frequency Protection

WU Tie-jun(Qingyuan Power Supply Bureau,Qingyuan,Guangdong 511515,China)  
In view of the anti-jamming question of high-frequency protection,the paper first analyzes the high-frequency channel of high-frequency protection,the generation and intruding means of lightning waves and other traveling waves,thus discriminating different characteristics among high-frequency signals,lightning waves and other traveling waves.It proposes to connect the serial codirectional double-winding reactor to the ends of radio cable,clip the range of fall and peak of the lightning waves and other traveling waves,and reduce the shock effects of lightning waves and other traveling waves on the transceiver,in order to further enhance the anti-jamming ability of high-frequency protection.
【CateGory Index】: TM773
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 CUI Fang-fang(Zhejiang Zhoushan Electric Power Bureau,Zhoushan 316000,China);Analysis on Simulation of Inrush Current for Three Phase Transformer Based on MATLAB[J];Journal of Anhui Electrical Engineering Professional Technique College;2010-01
2 WANG Xian-li(Xuancheng Power Supply Company,Xuancheng 242000,China);Discussion on 500kV 3/2 Wiring Protection Dead Zoon[J];Journal of Anhui Electrical Engineering Professional Technique College;2011-03
3 LIU Yang(Mengcheng power supply company,Mengcheng 233500,China);Single Supply Radial Grid 35kV Substation Protection Setting Calculation Method[J];Journal of Anhui Electrical Engineering Professional Technique College;2011-S1
4 LUO Hong-bo,GUO Jie(Xuancheng Power Supple Company,Xuancheng 242000,China);Selection and Exception Analysis of the Zinc Oxide Arrester[J];Journal of Anhui Electrical Engineering Professional Technique College;2012-01
5 ;Fast Fault Location Technology for Power Cable Based on GPS and Double Terminals Traveling Wave Information[J];Anhui Electric Power;2008-01
6 ;The Study on the Logical Coor dination of the Line Protection Relay with the Circuit Breaker in 220 kV System[J];Anhui Electric Power;2008-03
7 ;Optimized Coordinated Setting for Time-Reserve Directional Overcurrent Protection[J];Anhui Electric Power;2009-01
8 ;Survey of the Mthods of Fault Line Slection Based on Small Current Grounding System of Distribution Network[J];Anhui Electric Power;2010-02
9 LIU Jia-hai,YIN Zong-shi(Meishan Hydropower Station of Anhui Province,Jinzhai 237300,China);Application of black-start in Meishan Hydropower Station[J];Journal of Anhui Technical College of Water Resources and Hydroelectric Power;2007-04
10 WANG Xiang(Beijing Communication College,Beijing 100000,China);The Research of a New Microcomputer Line Protection Device Based on DSP[J];Journal of Anyang Institute of Technology;2006-06
China Proceedings of conference Full-text Database 10 Hits
1 LIU Yang (Mengcheng power supply company,Mengcheng 233500,China);Single Supply Radial Grid 35kV Substation Protection Setting Calculation Method[A];[C];2011
2 ;The analysis of Synthetic Lightning Shielding Scheme and Effect at Guangxi Television Launching Centre[A];[C];2002
3 Sun Huihao~1,Liu Yulin~1,Wu Lei~1,Li Mengling~2 (1.Power General Corporation of Shengli Oil Field,Shandong Province Dongying City 257000 2.Gudao Oil Production Plant of Sengli Oil Field,Shandong Province Dongying City 257068);Research on Transformer Modeling and Simulation Based on EMTP/ATP[A];[C];2009
4 YANYun-zhong FAN Ping HUANG Sheng-chun(XJ Electric Corporation,Xuchang 461000,China);THE RELIABILITY ANALYSIS OF THE SINGLE CPU MICROCOMPUTER-BASED FEEDER PROTECTION DEVICES AND ITS IMPROVING METHODS[A];[C];2006
5 SONG Xiao_zhou Beijing Sifang automatization Co.;LTD,Beijing 100085,China;Simple analysis for reliability design of relaying protection device[A];[C];2006
6 Li Peihua Liu Shuguang Qiu Jianxi(Xi'an Ploytechnic University,Xi'an 710048);Design of Protection Decvice for the Digital Transformer Based on DSP[A];[C];2006
7 JIAO Yan-Jun YUAN Feng WU Hong-Bo Institute of Electrical Engineering,North China Electric Power University,BaoDing 071003,China. YUAN Yu-Shan HuangLong Power Company,ShanXi Local Power Group,HuangLong 715700,China;Data Processing of Protection of UHV Transmission Lines Based on Bergeron Model and Karenbauer Transform[A];[C];2008
8 YUAN Zheng-Hua SONG Rui LI Zhen-Hai LIU Yan-Chao Luohe Power Supply Corporation,Luohe 462000,China;Analysis of a incorrect closing accident of 500 kV breaker[A];[C];2008
9 Shi Jiugen~(1,2) Hong Jie~1 Han Jianghong~1 (1 Engineering Research Center of Safety Critical Industry Measure and Control Technology of Ministry of Education Hefei 230009 China;2 GOCOM lnformation & Technology Co.LTD Hefei 230088 China);Design and application of embedded overcurrent protection algorithm for electromotor[A];[C];2008
10 Shi Jiu-gen1,2 Wang Lei1 Hong Jie1 Han Jiang-hong1 1 Engineering Research Center of Safety Critical Industry Measure and Control Technology of Ministry of Education,Hefei,230009,China 2 GOCOM Information & Technology Co.LTD,Hefei,230088,China;Analysis and Improvement of Inverse-time Ercurrent Protection Model for Electromotor[A];[C];2009
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved