Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Highway》 2008-04
Add to Favorite Get Latest Update

Test Research and Theoretical Prediction of Maximum Smoke Temperature Under Tunnel Ceiling

WANG Yan-fu1,JIANG Jun-cheng1,GONG Yanfeng1,ZHONG Xing-can2,MAO Jin-feng3,ZHOU Ping1 (1.College of Urban Construction Engineering,Nanjing University of Technology,Nanjing 210009,China;2.Second Survey and Design Institute of China Railway,Chengdu 610031,China; 3.PLA University of Science and Technology,Nanjing 210009,China)  
In order to research the fire properties of the municipal tunnel with openings on roof,full-scale fire tests are designed and conducted in the built tunnel.The longitudinal diversification data of maximum smoke temperature are collected.The tunnel fire flame model and formula built by H.Kurioka is validated by comparing test data with theoretically predictive results,which afforded scientific gist for construction of municipal road tunnel and can be used for directing the research and fire protection work of tunnel fire.
【Fund】: 国家自然科学基金资助项目 项目编号29936110 50206009
【CateGory Index】: U453.8
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 1 Hits
1 Yuan Jianping1,Fang Zheng1,Cheng Caixia2,Tang Zhi1 (1.School of Civil Engineering,Wuhan University,Wuhan 430072,China;2.China University of Mining and Technology (Beijing),Beijing 100083,China);Experiment Research on the Maximum Smoke Temperature around the Vault of a Tunnel on Fire[J];Chinese Journal of Underground Space and Engineering;2010-05
【Citations】
Chinese Journal Full-text Database 2 Hits
1 HONG Li-juan , LIU Chuan-ju(HVAC & GAS Engineering Institute, Tongji University, Shanghai 200092 P.R.China);Review of Research on Tunnel Fire Safety[J];;2005-01
2 Qu Li;Fire and Smoke Control in Tunnel[J];Undergrourd Engineering and Tunmels;2004-01
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 WANG Ze-yu,FENG Lian,ZHANG Fa-yong (College of Mechanical Engineering,Southwest Jiaotong University,Chengdu 610031 P.R.China);Tunnel Fire Numerical Simulation with the Force of Shaft's "Chimney Effect"[J];Chinese Journal of Underground Space and Engineering;2006-03
2 WANG Li-hui,Wu Xi-ping(Ventilating,Air-condition and Gas Research Institute,Tongji University,Shanghai 200092,China);The Affect on the Subway System from the Piston Action Wind[J];Chinese Journal of Underground Space and Engineering;2007-01
3 ZHANG Nian,MAO Jun,TAN Zhongsheng,XI Yanhong(School of Civil Engineering,Beijing Jiaotong University,Beijing 100044,China);Research on the Problem of Emergency Station Safe Evacuation in Super-Long Tunnel[J];Journal of Beijing Jiaotong University;2010-01
4 Huang Peilei,Hao Xuejun,Yang Hui,Qian Shenxian (School of Environment and Energy Engineering,BUCEA Beijing 100044);Experimental Study on Critical Ventilation Velocity in Tunnel[J];Journal of Beijing University of Civil Engineering and Architecture;2009-02
5 ZHOU Xiang-chuan,ZHAO Wang-da,NI Tian-xiao(School of Civil and Architectural Engineering,Central South University,Changsha 410075,China);The influence of roof spacer on the smoke spread and temperature in highway tunnel fire[J];Journal of Railway Science and Engineering;2011-01
6 ZENG Yan-hua,HE Chuan (Department of Tunnel and Underground Engineering,Southwest Jiaotong University,Chengdu 610031,China);Research on Rescue Ventilation in Highway Tunnel with Air Exchange Shaft[J];Journal of Disaster Prevention and Mitigation Engineering;2009-02
7 LI Jun-mei,FU Cheng-yun,LI Yan-feng,DAI Lin (College of Architecture and Civil Engineering,Beijing University of Technology,Beijing 100124,China);Numerical Studies on Development Law of Fire Environment in Urban Traffic Tunnel[J];Journal of Disaster Prevention and Mitigation Engineering;2010-05
8 WENG Tao1 HU Long-hua2(1 Prevention and Supervision Division Fire Department of Anhui Province,Hefei 230031,China 2 State Key Laboratory of Fire Science,Uiversity of Science and Technology of China,Hefei 230027,China);Review of Research on Fire Prevention of Traffic Tunnel[J];China Public Security(Academy Edition);2010-03
9 WU De-xing~(1,2) WANG Bo~3 ZHENG Guo-ping~2 (1.Department of Underground Engineering,Southwest Jiaotong University,Chengdu Sichuan 610031,China; 2.Zhejiang Provicial Plan Design & ResearchInstitute of Communications,Hangzhou Zhejiang 310006,China; 3.Zhejiang Highway and Water Transportation Engineering Consulting Corpration,Hangzhou Zhejiang 310005,China);Analysis on the "Chimney Effect" and Smoke Extraction Countermeasures for Fire in Cangling Tunnel[J];Journal of Highway and Transportation Research and Development;2008-06
10 YI Saili (Shanghai Institute of Technology,Shanghai 200235,China);Analysis on Characteristics of Fire Smoke in Highway Tunnel by CFD Simulation[J];Journal of Highway and Transportation Research and Development;2010-01
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 YAN Zhi guo;Experimental Study on Temperature Field Distribution of the Fire in Qinling King-size Highway Tunnel[J];Underground Space;2003-02
2 YAN Zhi-guo~1,ZHU He-hua~1,ZHANG Jian-jun~2(1.Department of Geotechnical Engineering,Tongji University,Shanghai 200092,China;2.Tianjin Municipal Engineering Design & Research Institute,Tianjin 232001,China);A Study on Fire Damage to Tunnel Lining and Fire-Control Measures[J];Chinese Journal of Underground Space and Engineering;2006-04
3 YAO Jian1,ZHU He-hua1,YAN Zhi-guo1,ZENG Ling-jun1(1.Department of Geotechnical Engineering,Tongji University,Shanghai 200092 P.R.China);Experimental Research on Mechanical Property of Tunnel Lining Concrete after High Temperature Effect[J];Chinese Journal of Underground Space and Engineering;2007-01
4 Chen Zhengjie Di Yongmei Yang Zhihao;Fire Test of Reinforcement Bar Planted Bracket for Tunnel Smoke Duct[J];Underground Engineering and Tunnels;2008-01
5 Lu ping, Cong Beihua, Liao Guangxuan, Fan Weicheng, Li Peide (State Key Laboratory of Fire Science, University of Science and Technology of China,Hefei 230026, China);Study of Fire Smoke Flow Characteristics of Horizontal Tunnel Using Longitudinal Ventilation[J];Engineering Science;2004-10
6 ZHANG Yan , XU Zhi-sheng (Disaster Prevention Science and Safety Technology Institute, Central South University, Changsha, Hunan 410075, China);EXPERIMENTAL STUDY ON STRESS-STRAIN RELATIONSHIP OF CFRP-CONFINED CONCRETE PRISM AFTER FIRE[J];Engineering Mechanics;2008-05
7 LIU You-zhi 1,ZHANG Guo-xin 1,ZHU Yue-ming 2 (1.China Institute of Water Resources and Hydropower Research,Beijing,100038,China; 2.College of Water Conservancy&Hydroelectric Engineering,Hohai Universtiy,Nanjing,Jiangsu 210098,China);STUDY ON CONCRETE MOISTURE AND DRYING SHRINKAGE BASED ON MESOSCOPICAL DAMAGE MODEL[J];Engineering Mechanics;2008-07
8 Shi Xudong; Guo Zhenhai (Tsinghua University);ANALYSIS OF THE TEMPERATURE FIELD OF REINFORCED CONCRETE STRUCTURE[J];ENGINEERING MECHANICS;1996-01
9 WANG Xin WANG Hai SHi Ming-Heng YU Wei-Ping (Department of Power Engineering, Southeast University, Nanjing 210096, China);COUPLED HEAT AND MASS TRANSFER IN POUOUS MEDIA DURIING RAPID DRYING PROCESS[J];Journal of Engineering Thermophysics;2001-03
10 GAO Xiaojian KAN Xuefeng YANG Yingzi(School of Civil Engineering,Harbin Institute of Technology,Harbin 150006,China);SHRINKAGE DISTRIBUTION OF CONCRETE WITH ONE SURFACE EXPOSED TO DRY CONDITION[J];Journal of the Chinese Ceramic Society;2009-01
【Secondary References】
Chinese Journal Full-text Database 2 Hits
1 ZHANG Yan,XU Zhi-sheng(Disaster Prevention Science and Safety Technology Institute,School of Civil Engineering and Architecture,Central South University,Changsha,Hunan,410075,China);Discussion on effects of moisture contents in RC fire resistant experiments[J];Fire Safety Science;2010-04
2 ZHU Hua1,FANG Zheng2(1.Fire Corps of Hubei Province;2.School of Civil Engineering,Wuhan University,Wuhan,Hubei Province 430070,China);The Selection of Evacuation Methods and the Analysis in Wuhan Yangtze River Tunnel[J];Journal of Chinese People's Armed Police Force Academy;2011-06
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 MAO Chao-jun1, HE Shi-jia1, LAN Bin1, ZHANG Qing-ming2(1 Sichuan Fire Research Institute of Public Security Ministry, Dujiangyan 611830, Sichuan, China; 2 Sichuan Tianfu Fire Resistive Material Ltd., Dujiangyan 611830, Sichuan, China );Study on an environmental-friendly fire-proofing coating for tunnel linings[J];Journal of Safety and Environment;2005-04
2 FENG Lian et al.;Numerical Simulation of Smoke Control in Subway Fire[J];Underground Space;2002-01
3 ZHANG Wei et al.;Prevention of Fire in Urban Underground Traffic Tunnels[J];Underground Space;2002-03
4 CHEN Li dao et al;Study on Prevention and Control of Fire in Highway Tunnel[J];Underground Space;2003-01
5 YAN Zhi guo;Experimental Study on Temperature Field Distribution of the Fire in Qinling King-size Highway Tunnel[J];Underground Space;2003-02
6 WANG Ming nian et al;Study on Distribution of Temperature Field of Fire in Highway Tunnel[J];Underground Space;2003-03
7 Fan Weicheng, Liu Naian (State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei 230026,China)[;Fire Safety Science ——A Promising and Interdisciplinary Engineering Scientific Field[J];Engineering Science;2001-01
8 ZHANG He-Ping WANG Wei YANG Yun XU Liang ZHU Wu-Ba((State Key Laboratory of Fire Science, USTC, Hefei 230027, China);FULL-SCALE EXPERIMENTAL STUDY OF SOFA HEAT RELEASE RATE IN COMPARTMENT[J];Journal of Engineering Thermophysics;2005-01
9 Feng Lian (College of Mechanical Engineering, Southwest Jiaotong Univ. , Chengdu 610031);The Study and Development of the Subway Environmental Control and Numerical Simulation[J];Urban Mass Transit;1999-02
10 CAO Zhi ming,YANG Qi xin (Southwest Jiaotong University, Chengdu 610031, China);A Study on Scheme of Ventilation Organization Experiments in Condition on Fire in Long Highway Tunnel Through Zhongnan Mountain of Qinling Range[J];Highway;2003-07
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved