Design and calibration of single stria section contour sensor

YU Xiao-yang1,LU Bing-hui1,LI Qi1,LIU Hao2(1.College of Measurement-control Technology & Communication Engineering, Harbin University of Science and Technology, Harbin 150080, China;2.School of Electrical Engineering, Harbin Institute of Technology, Harbin 150040,China)  
In order to optimize the design and calibration of the structural parameters of single stria section contour sensor, a mathematic model that the single stria section contour sensor measures the coordinates of the spatial points is established. The measurement errors of the single stria section contour sensor are analyzed based on the mathematic model and the relationship between the structural parameters of the sensor and the measurement errors is obtained. Based on the comprehensive consideration of the effect of the structural parameters on the measurement accuracy, the criterion for designing the structural parameters of the sensor is given.A practical example of the design and calibration of the structural parameters is introduced to demonstrate its implementation,and the measurement accuracy of the sensor is proved by an experiment. The results indicate that relative depth measurement error of real system is less than 0.3%, and the complex surface reconstructed by real system has a good visual effect.
【Fund】: 国家自然科学基金资助项目(No.60572030);; 黑龙江省教育厅海外学人科研基金资助项目(No.1055HZ027)
【CateGory Index】: TP212
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 6 Hits
1 WU Zhang liang, LU Rong sheng, GONG Neng gang, FEI Ye tai(School of Instrument and Instrumentation, Hefei University of Technology,Hefei 230009, China);Optimization of the Structural Parameters of Line-structured Light Visual Sensors[J];Journal of Transcluction Technology;2004-04
2 TIAN Qing-guo,GE Bao-zhen,DU Pu,YU Dao-yin,LU Qie-ni (Key Laboratory of Opto-electronics Information and Science of Education Ministry,Tianjin University,Tianjin 300072,China);Measurement of human figure size based on laser 3D scanning[J];Optics and Precision Engineering;2007-01
3 LI Zhe,DING Zhen-liang,YUAN Feng (Department of Automatic Measurement and Control,Harbin Institute of Technology,Harbin 150001,China);Global calibration method for multi-vision measurement system with coplanar targets[J];Optics and Precision Engineering;2008-03
4 XUE Ting1,WU Bin2,ZHANG Tao1,YE Sheng-hua2(1.College of Electrical and Automatic Engineering,Tianjin University,Tianjin 300072,China; 2.State Key Laboratory of Precision Measuring Technology & Instrument,Tianjin University,Tianjin 300072,China);Analysis on round-hole orientation error based on structured light stripe vision sensor[J];Optics and Precision Engineering;2008-04
5 QIU Maolin (Beijing Open Lab of Cognitive Sciences, University of Sciences and Technology of China, Beijing 100039) MA Songde LI Yi (National Lab of Pattern Recognition, Institute of Automation, Chinese Academy of Sciences Beijing 100080);OVERVIEW OF CAMERA CALIBRATION FOR COMPUTER VISION[J];;2000-01
6 FENG Jun-yan,FENG Qi-bo,KUANG Cui-fang (Department of Physics, Beijing Jiaotong University, Beijing 100044,China);Present Status of High Precision Laser Displacement Sensor Based on Triangulation[J];Journal of Applied Optics;2004-03
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 YANG Chun-ping, WU Jian, HONG Liang, FENG Yan-yan(School of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu 610054, CHN);Application of 2-CCD System in 3-D Surface Shape Measurement[J];Semiconductor Optoelectronics;2004-03
2 YU Yongsheng BI Weitao (State Key Laboratory of Turbulence and Complex Systems, Peking University, Beijing,100871);A Calibration Method for Far-Field Photogrammetry and Its Application[J];;2006-01
3 ZHANG Xue-min, SONG Shu-wen (Dept. 2, The First Aeronautic Institute of Air Force, Xinyang 464000, China);Improvement of Two-stage Camera Calibration[J];Ordnance Industry Automation;2006-09
4 YU Yongsheng BI Weitao(State Key Laboratory of Turbulence and Complex Systems, Peking University, Beijing,100871);A Calibration Method for Far-Field Photogrammetry and Its Application[J];Acta Scientiarum Naturalium Universitatis Pekinensis;2006-05
5 Zou Zhiyong Li Xiaoxing Zhou Xianbin (School of Mechanical Engineering and Automation, Beijing University of Aeronautics and Astronautics, Beijing 100083, China);Field calibration technique for 3D surface non-contact measurement system[J];Journal of Beijing University of Aeronautics and Astronautics;2004-02
6 Wang Tianmiao Luan Sheng Hu Lei (School of Mechanical Engineering and Automation,Beijing University of Aeronautics and Astronautics,Beijing 100191,China);Reproject and correct optimization in determining C-arm extrinsic parameters based on geometry constraints[J];Journal of Beijing University of Aeronautics and Astronautics;2008-07
7 WANG Hai-tao,ZHANG Li,XIANG Hui-yu (College of Mechanical and Automation Engineering,Beijing Technology and Business University,Beijing 100037,China);MENSUREMENT OF PRINCIPAL PLASTIC STRAIN OF AUTOMOBILE PANEL BASED ON VISION[J];Journal of Beijing Technology and Business University(Natural Science Edition);2008-04
8 SUN Xian-bin1,2, LI De-hua1, YIN Jie2, YAO Xun1 (1. State Key Laboratory for Image Processing and Intelligent Control, Institute of Pattern Recognition and Artificial Intelligence, Huazhong University of Science and Technology, Wuhan 430074, China; 2. Hubei University of Technology, Wuhan 430068, China);Camera Calibration for 3D Color Scanning System Using Virtual 3D Model[J];计算机辅助绘图设计与制造(英文版);2007-02
9 YANG Hua-chao1,DENG Ka-zhong1,YANG Guo-dong2,NIU Xue-feng2,DONG Si-bei21.School of Environment and Spatial Informatics,China University of Mining & Technology,Xuzhou,Jiangsu 221008,China2.College of GeoExploration Science and Technology,Jilin University,Changchun 130026,China;Deformation Measurement of Similar Material Model of Mine Strip Exploitation[J];Journal of Jilin University(Earth Science Edition);2007-01
10 SHAO Liang, DU Xin, YING Zhuo-yu, GU Wei-kang (Department of Information Science & Electronic Engineering Zhejiang University, Hangzhou 310027, China);Design and Implementation of Visual Processing System Based on FPGA[J];Journal of Transcluction Technology;2005-01
China Proceedings of conference Full-text Database 10 Hits
1 Guosheng Yang1 Hao Yan1 Lichao Chen2 Min Tan1 (1 Institute of Automation, Chinese Academy of Sciences, Beijing 100080 China) (2Dep. of Computer Science, North China University of Science and Technology, Taiyuan 030051);Research on Algorithm of Camera Calibration Based on Polynomial for a Mobile Robot[A];[C];2003
2 Zhang Li 1,2,Zhang Xiangxue 2,Ding Jinyun 1,Zhang Zhifeng 1 1.School of Science,Beijing Jiaotong University,Beijing,100044,2.College of Science,Beijing Forestry University,Beijing,100083,;The Laser Triangulation Measurement System Based on Embedded System[A];[C];2007
3 HE Ning, ZHOU Tian-hua, SI Li-hong Department of Communication and Information Engineering, GUET, Guilin 541004, China;Design and realization of the height of liquid level measurement with laser[A];[C];2005
4 WANG Dong-shu PAN Feng XIANG Long-jiang XU Xin-he Institute of Artificial Intelligence and Robotics,Northeastern University,Shenyang 110004,China.;Brain surgical robot system based on visual servo[A];[C];2004
5 FU Li, XU Xin-he (Institute of Artificial Intelligence & Robotics, Northeastern University, Shenyang 110004, China; Shenyang University, Shenyang 110044, China.;Review on methods in data capture of human gait on basis of computer-vision[A];[C];2005
6 JingJianhui Zhang Zhendong Wu Wenqi (School of Electrical Engineering and Automation, Hebei University of Technology, Tianjin China 300130) (Department of Computer Science and Technology, Tsinghua University, Beijing China 100084);Application of Camera Calibration in Robot Vision System[A];[C];2003
7 LI Bo,DONG Rong,CHEN Qi-mei (Department of Electronic Science and Engineering,Nanjing University,Nanjing 210093,China);Automatic Calibration Method for PTZ Camera[A];[C];2009
8 Tan Yuegang Wu Zhengping (Wuhan University of Technology,Wuhan 430070);A New Three-dimensional Reconstruction Method Using Two Cameras[A];[C];2001
9 Yang Liang~(1,2),Guo Xinyu~1,Zhao Chunjiang~1 (1.National Engineering Research Center for Information Technology in Agriculture,Beijing 100097,China; 2.College of Information Engineering,Capital Normal University,Beijing 100037,China);Stereo Vision Technology and Its Application in Agriculture[A];[C];2007
10 Song Xuefeng Yang Ming Wang Hong State Key Laboratory of Intelligent Technology and Systems, Tsinghua University, Beijing 100084;A Grid Texture Detection Method For Camera Calibration[A];[C];2001
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 WU Hong fang (Dept. of Text.& Cost. Engn., Anuhui Institute of Mechanical and Electrical Engineering, Wuhu 241000, China);CAT for measuring figure size and system of clothing CAD[J];Journal of Anhui Institute of Mechanical and Electrical Engineering;2000-04
2 Xu Yuan Zhang Guangjun Wei Zhenzhong (School of Automation Science and Electrical Engineering, Beijing University of Aeronautics and Astronautics, Beijing 100083, China);Method for acquiring characteristic pointsin the calibration of line structure-light sensor[J];Journal of Beijing University of Aeronautics and Astronautics;2004-01
3 CHENG Ji-wei, GONG Ma-li, JIA Wei-pu, LIU Xing-zhan, YAN Ping, ZHANG Hai-tao (Dept of Precision Inst,Tsinghua University,Beijing 100084,China);Application of position sensitive detector in tilted angle measuement[J];Journal of Transducer Technology;2002-10
4 Wang Xun (Department of Basic Course, Fushun Petrolem Institute, Liaoning Fushun 113001, China);Design of Optical Image-Forming System for Non-Contact Measurement[J];JOURNAL OF FUSHUN PETROLEUM INSTITUTE;2000-02
5 ZOU Feng-jiao, SU Xian-yu , LI Mei-ju ( Opto-Electronics Department, Sichuan University, Chengdu 610064, China );Camera linear calibration method with a coplanar target[J];Opto-electronic Engineering;2005-04
6 GE Baozhen, SUN Mingrui, LU Qieni, MU Bing, SUN Yuchen, ZHANG Yimo cience of Education Ministry,Tianjin University,Tianjin 300072,China);Research of a Laser 3D Body Scanning System by Light Stripe Method[J];Journal of Optoelectronics.laser;2003-07
7 Feng Lishuang et al;Three dimensional Measuring Technology for BGA Chip Leads[J];TOOL ENGINEERING;2000-05
8 Guo Hong Deng Feng Zhang Jing et al;Research on Laser Scanning 3D Measurement Technology Based on Image Processing[J];Tool Engineering;2004-11
9 HE Zhong hai, WANG Bao guang (State key laboratory of precision measuring technology and instrument,Tianjin University, Tianjin 300072, China);Model and imaging formula of the line structured light sensor[J];Optics and Precision Engineering;2001-03
10 YE Hai-jia, CHEN Gang, XING Yuan (Department of Plasticity Forming Engineering, Shanghai Jiaotong University, National Die & Mould CAD Engineering Research Center, Shanghai 200030, China);Stereo matching in 3D measurement system using double CCD structured light[J];Optics and Precision Engineering;2004-01
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved