Calculation or Close Double Row Orifice Rectangulsr Aerostatic Slideways

Tao Jiasheng(Changchun Institute of Optics and Fine Mechanics,Chinese Academy of Sciences, Changchun 130022)  
In this paper, using common proportion relationship in practice engineering, highpressure areas pressure is analyzed with Finite Element Methed. A conclusion that the highpressure areas coefficient within the orifice restricting is a constant is reached, thus make theway smooth for calculating the common structure form aerostatic slideways.