Precise measurement instrument for temperature and specific radiance using lasers and pyroelectric detector in real-time

SHI De heng 1, LIU Yu fang 2, CHEN Yu ke 1 (1. Department of Foundation, the First Aeronautical College of Air Force, Xinyang 464000, China) (2. Department of Physics, Henan Normal University, Xinxiang 453002, China)  
This paper presents a new kind of the intelligent specific radiance and temperature measurement instrument using laser diode InGaAs/I as a light source and using pyroelectric detector and chip microprocessor in real time. This instrument consists of three parts: optical emitting and receiving system, signal amplifying and controlling system, and display system. The principle and structure of this instrument are introduced in detail in this paper. The key technologies and the corresponding solution methods are analyzed. Measurement precision of the specific radiance and the temperature are discussed. To polishing steel cast at 427℃, the results are NETD≤0 32K ,σ ε λ =6 5×10 -3 ,|σ ε λ /ε λ |=1 20%;σ T=1 06K ,|σ T /T|=0 152%.
【CateGory Index】: TN24
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 9 Hits
1 SHI De heng 1, XU Qi fu 1, LIU Yu fang 2 (1. Department of Foundation, The First Aeronautical College of Air Force, Xinyang 464000, China) (2. Henan Normal University, Xinxiang 453002, China);An IR colorimeter using pyroelectric detector[J];OPTICAL TECHNOLOGY;2000-05
2 SHI De heng 1, LIU Xin jian 2, XU Qi fu 1, CHEN Yu ke 1, LIU Yu fang 3 (1 Deparment of Foundation, The First Aeronautical College of Air Force, Xinyang 464000, China) (2 Department of Physics, Xinyang College of Education, Xinyang 464000;Analyses of sensitivity about temperature real-time measurement system using lasers and pyroelectric detector[J];OPTICAL TECHNOLOGY;2000-06
3 SHI De heng 1, XU Qi fu 1, LIU Yu fang 2 (1 Department of Foundation, The First Aeronautical College of Air Force, Xinyang 464000, China) (2 Department of Physics, Henan Normal University, Xinxiang 453002, China);Optimization about temperature real-time measurement system using lasers and pyroelectric detector[J];Optical Technology;2001-02
4 LIU Yu-fang1, ZHU Zhun-lue1, SHI De-heng2, HUANG G uo-qing2, CHEN Yu-ke2 (1. Department of Physics, Henan Normal University, Xinxiang, Henan453002, Chi na)(2. Department of Foundation, The First Aeronautical College of Air Force, Xinya ng464000, China);Control on reflection radiation and optimal design of water-cooled shelter pl ate of a real-time temperature measurement system[J];Optical Technique;2003-05
5 LI Rui (Xinyang Teachers College,Xinyang 464000,China);Accuracy-Measurement Instrument for Temperature and Emissivity Using Lasers and Standard Heat-noise Radiating Source and Pyroelectric Detector in Real-time[J];Infrared Technology;2001-04
6 Shi Deheng 1 Liu Yufang 2 (Department of Foundation,The First Aeronautical College of Air Force,Xinyang,Henan Province 464000) (Department of Physics,Henan Normal University,Xinxiang,Henan Province 453002);Optimized choice of laser source in temperature real time measurement system[J];Laser Journal;2000-06
7 Shi Deheng 1 Xu Qifu 1 Chen Yuke 1 Liu Yufang 1 ( 1Department of Foundation,The First Aeronautical College of Air Force,Xinyang,Henan Province 46400) ( 2Department of Physics,Henan Normal University,Xinxiang,Henan Province 453000);Measures on improving sampling accuracy of temperature real-time measurement system[J];Laser Journal;2001-01
8 Shi Deheng 1 Guo Feng 1 Liu Yufang 2 Li Rui 3 ( 1Department of Foundation,The First Aeronautical College of Air Force,Xinyang 464000) ( 2Department of Physics,Henan Normal University,Xinxiang 453002) ( 3Department of Computer Science,Xiny;Accurate-measurement instrument for temperature and specific radiance using lasers and standard heat-noise radiating source and pyroelectric detector in real-time[J];Laser Journal;2002-02
9 Shi Deheng 1 Zhao Ye 2 Zou Zhibin 1 Chen Yuke 1 ( 1Department of Foundation ,The First Aeronautical College of Air Force,Xinyang,Henan Province 464000) ( 2Department of physics,Henan Normal University,Xinxiang,Henan Province 453002);Effect on measurement accuracy of temperature in real-time measurement system by surrounding temperature and disturbing light[J];Laser Journal;2002-03
【Citations】
Chinese Journal Full-text Database 7 Hits
1 SHI De heng, CHEN Yu ke (Department of Foundation, the First Aeronautical College of Air Force, Xinyang 464000, China);Precise measurement instrument for temperature and specific radiance of high temperature object using laser and standard heat noise radiating source and 8031 chip microprocessor[J];OPTICAL TECHNOLOGY;1999-06
2 SHI De heng, CHEN Yu ke (The First Aeronautical College of Air Force, Xinyang 464000, China);System for precisely measuring temperature and radiativity of high temperature object[J];OPTICAL TECHNOLOGY;1999-03
3 Liu Tiean (Shengyang University,Shengyang, 110044);Study on the Accuracy of Flame Temperature Measurement[J];INFRARED TECHNOLOGY;1996-06
4 Hu Ruihua, *Luan Song,Sun Ningke (Dalian Institute of Light Industry,Dalian,116034) *(Dalian Institute of Electron,Dalian,116021);Radiation Thermometer for Determining Temperature and Emissivity[J];INFRARED TECHNOLOGY;1998-02
5 Shi Deheng (Dept.of Foundation,The First Aeronautical College of Air Force,Xinyang 464000) Chen Anjun (Dept.of Physics,Xinyang Teachers College,Xinyang 464000);An intelligent measurement instrument of specific radiance of high temperature object using laser in real time[J];LASER JOURNAL;1998-06
6 Shi Deheng Chen Yuke (Department of Foundation,The First Aeronautical College of Air force,Xinyang 464000);An intelligent measurement instrument of specific radiance and temperature of hightempera ture object using laser in real time[J];LASER JOURNAL;1999-03
7 Jiang Shichang;The Infrared Measuring Technology for Temperature[J];Process Automation Instrumentation;1996-04
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 DING Wan-shan,CHEN Xiao-gang,ZHANG Jian,XIA Zhen-chun(College of Automation Engineering,Nanjing University of Aeronautics and Astronautics,Nanjing 210016,China);Micro-automobile emission diagnosis system based on spectral absorption[J];Transducer and Microsystem Technologies;2009-02
2 ZHANG Jian,DING Wan-shan(College of Automation Engineering,Nanjing University of Aeronautics and Astronautics,Nanjing 210016,China);High-temperature detecting system based on ARM[J];Transducer and Microsystem Technologies;2009-04
3 XIA Yuanfei,LIU Huanlong,LIU Yong(The First Aeronautic Institute of Air Force,Xinyang 464000,China);Application of Laser Diode in Airplane Engine Real-time Temperature Measurement System[J];Informatization Research;2009-02
4 FU Tai-ran1, CHENG Xiao-fang2, ZHONG Mao-hua1, YANG Zang-jian21. China Academy of Safety Science & Technology, Beijing 100029, China2. Department of Thermal Science and Energy Engineering, University of Science and Technology of China, Hefei 230027, China;Analyses of Spectral Emissivity in Radiation Temperature Measurement[J];Spectroscopy and Spectral Analysis;2008-01
5 TAN Xin quan, MEI Xiao ying, SUN Hai wei, XU Sheng hui (Dept. of Electronic & Information Engineering, Huazhong Univ. of Sci. & Tech., Wuhan 430074, China);Hardware design of the real time acquisition for a color image[J];OPTICAL TECHNOLOGY;1999-06
6 SHI De heng, CHEN Yu ke (Department of Foundation, the First Aeronautical College of Air Force, Xinyang 464000, China);Precise measurement instrument for temperature and specific radiance of high temperature object using laser and standard heat noise radiating source and 8031 chip microprocessor[J];OPTICAL TECHNOLOGY;1999-06
7 SHI De heng 1, XU Qi fu 1, LIU Yu fang 2 (1. Department of Foundation, The First Aeronautical College of Air Force, Xinyang 464000, China) (2. Henan Normal University, Xinxiang 453002, China);An IR colorimeter using pyroelectric detector[J];OPTICAL TECHNOLOGY;2000-05
8 SHI De heng 1, LIU Xin jian 2, XU Qi fu 1, CHEN Yu ke 1, LIU Yu fang 3 (1 Deparment of Foundation, The First Aeronautical College of Air Force, Xinyang 464000, China) (2 Department of Physics, Xinyang College of Education, Xinyang 464000;Analyses of sensitivity about temperature real-time measurement system using lasers and pyroelectric detector[J];OPTICAL TECHNOLOGY;2000-06
9 SHI De heng 1, XU Qi fu 1, LIU Yu fang 2 (1 Department of Foundation, The First Aeronautical College of Air Force, Xinyang 464000, China) (2 Department of Physics, Henan Normal University, Xinxiang 453002, China);Optimization about temperature real-time measurement system using lasers and pyroelectric detector[J];Optical Technology;2001-02
10 SHI De heng, CHEN Yu ke (The First Aeronautical College of Air Force, Xinyang 464000, China);System for precisely measuring temperature and radiativity of high temperature object[J];OPTICAL TECHNOLOGY;1999-03
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 Deng Xingzhong ;Yang Zifang; Liu Bo(Huazhong University of Science and Technology);Measure on Improving Sampling Precision of the Optic Fiber Intelligent Colorimetric Thermometer[J];Journal of Electronic Measurement and Instroment;1995-02
2 SHI De heng, CHEN Yu ke (Department of Foundation, the First Aeronautical College of Air Force, Xinyang 464000, China);Precise measurement instrument for temperature and specific radiance of high temperature object using laser and standard heat noise radiating source and 8031 chip microprocessor[J];OPTICAL TECHNOLOGY;1999-06
3 SHI De heng 1, LIU Xin jian 2, XU Qi fu 1, CHEN Yu ke 1, LIU Yu fang 3 (1 Deparment of Foundation, The First Aeronautical College of Air Force, Xinyang 464000, China) (2 Department of Physics, Xinyang College of Education, Xinyang 464000;Analyses of sensitivity about temperature real-time measurement system using lasers and pyroelectric detector[J];OPTICAL TECHNOLOGY;2000-06
4 SHI De heng 1, XU Qi fu 1, LIU Yu fang 2 (1 Department of Foundation, The First Aeronautical College of Air Force, Xinyang 464000, China) (2 Department of Physics, Henan Normal University, Xinxiang 453002, China);Optimization about temperature real-time measurement system using lasers and pyroelectric detector[J];Optical Technology;2001-02
5 SHI De heng, CHEN Yu ke (The First Aeronautical College of Air Force, Xinyang 464000, China);System for precisely measuring temperature and radiativity of high temperature object[J];OPTICAL TECHNOLOGY;1999-03
6 Jiang Shichang (Shanghai Institute of Process Automation Instrumentation, Shanghai, 200233);Effect of the Medium in Radiation Transmitting Path on Single-band Infrared Themometry[J];Infrared Technology;1993-06
7  HUANG Xue-yu(Xinyang Normal College, Xinyang 464000, China);A Accurate Real-Time Measurement Instrument for Temperature and Radiance of High Temperature Object[J];INFRARED TECHNOLOGY;1999-05
8 HUANG Xue-yu (Xinyang Teacher's College, Xinyang 464000, China);A Accurate Real-Time Measurement Instrument for Temperatureand Radiance of High Temperature Object[J];INFRARED TECHNOLOGY;1999-06
9 Liu Tiean (Shengyang University,Shengyang, 110044);Study on the Accuracy of Flame Temperature Measurement[J];INFRARED TECHNOLOGY;1996-06
10 Shi Deheng 1 Liu Yufang 2 (Department of Foundation,The First Aeronautical College of Air Force,Xinyang,Henan Province 464000) (Department of Physics,Henan Normal University,Xinxiang,Henan Province 453002);Optimized choice of laser source in temperature real time measurement system[J];Laser Journal;2000-06
【Secondary References】
Chinese Journal Full-text Database 10 Hits
1 LIU Yu-fang1, ZHU Zhun-lue1, SHI De-heng2, HUANG G uo-qing2, CHEN Yu-ke2 (1. Department of Physics, Henan Normal University, Xinxiang, Henan453002, Chi na)(2. Department of Foundation, The First Aeronautical College of Air Force, Xinya ng464000, China);Control on reflection radiation and optimal design of water-cooled shelter pl ate of a real-time temperature measurement system[J];Optical Technique;2003-05
2 LI Zhen-xin~(1,2),SHI De-heng~3,LI Shi-pu~1 (1.Biomedical Materials and Engineering Centre,Wuhan University of Technology, Wuhan 430070,China) (2.Department of Life Science and Technology,Xinxiang Medical College,Xinxiang 453003,China) (3.Department of Physics,Henan Normal University,Xinxiang 453007,China);A temperature measurement system based on liquid crystal valve modulation[J];Optical Technique;2006-03
3 LI Rui (Xinyang Teachers College,Xinyang 464000,China);Accuracy-Measurement Instrument for Temperature and Emissivity Using Lasers and Standard Heat-noise Radiating Source and Pyroelectric Detector in Real-time[J];Infrared Technology;2001-04
4 Shi Deheng 1,Guo Feng 1 ;Liu Yufang 2 ,Chen Yuke 1 ( 1*"Department of Foundation,The First Aeronautical College of Air Force,Xinyang,464000) ( 2*"Department of Physics,Henan Normal University,Xinxiang,453002);Measures to improve the accuracy of a real-time temperature measurement system[J];Laser Technology;2002-02
5 Shi Deheng 1 Liu Yufang 2 (Department of Foundation,The First Aeronautical College of Air Force,Xinyang,Henan Province 464000) (Department of Physics,Henan Normal University,Xinxiang,Henan Province 453002);Optimized choice of laser source in temperature real time measurement system[J];Laser Journal;2000-06
6 Shi Deheng 1 Xu Qifu 1 Chen Yuke 1 Liu Yufang 1 ( 1Department of Foundation,The First Aeronautical College of Air Force,Xinyang,Henan Province 46400) ( 2Department of Physics,Henan Normal University,Xinxiang,Henan Province 453000);Measures on improving sampling accuracy of temperature real-time measurement system[J];Laser Journal;2001-01
7 Shi Deheng 1 Guo Feng 1 Liu Yufang 2 Li Rui 3 ( 1Department of Foundation,The First Aeronautical College of Air Force,Xinyang 464000) ( 2Department of Physics,Henan Normal University,Xinxiang 453002) ( 3Department of Computer Science,Xiny;Accurate-measurement instrument for temperature and specific radiance using lasers and standard heat-noise radiating source and pyroelectric detector in real-time[J];Laser Journal;2002-02
8 Shi Deheng 1 Zhao Ye 2 Zou Zhibin 1 Chen Yuke 1 ( 1Department of Foundation ,The First Aeronautical College of Air Force,Xinyang,Henan Province 464000) ( 2Department of physics,Henan Normal University,Xinxiang,Henan Province 453002);Effect on measurement accuracy of temperature in real-time measurement system by surrounding temperature and disturbing light[J];Laser Journal;2002-03
9 Sun Meisheng Cheng Yao Han Jianbin Zhang Cong (Automation Department of Tsinghua University,Beijing 100084);Study on high-voltage pulse waveform measurement by using semiconductor lasers[J];Laser Journal;2003-03
10 SHI De-heng 1,2,3, LIU Yu-fang 2, SUN Jin-feng 2,3, HUANG Guo-qing 1, CHEN Yu-ke 1 1Department of Foundation, The First Aeronautical College of Air Force, Xinyang, Henan 464000, China 2Department of Physics, Henan Normal University, Xinxiang, Henan 453002, China 3Institute of Atomic and Molecular Physics, Sichuan University, Chengdu, Sichuan 610065, China;Effect and Control on Temperature Measurement Accuracy of Real-time Temperature Measurement System by Reflection Radiation and Detector Radiation Itself[J];Chinese Journal of Lasers;2004-01
【Secondary Citations】
Chinese Journal Full-text Database 9 Hits
1 Deng Xingzhong ;Yang Zifang; Liu Bo(Huazhong University of Science and Technology);Measure on Improving Sampling Precision of the Optic Fiber Intelligent Colorimetric Thermometer[J];Journal of Electronic Measurement and Instroment;1995-02
2 SHI De heng, CHEN Yu ke (The First Aeronautical College of Air Force, Xinyang 464000, China);System for precisely measuring temperature and radiativity of high temperature object[J];OPTICAL TECHNOLOGY;1999-03
3 Jiang Shichang (Shanghai Institute of Process Automation Instrumentation, Shanghai, 200233);Effect of the Medium in Radiation Transmitting Path on Single-band Infrared Themometry[J];Infrared Technology;1993-06
4 Hu Ruihua, *Luan Song,Sun Ningke (Dalian Institute of Light Industry,Dalian,116034) *(Dalian Institute of Electron,Dalian,116021);Radiation Thermometer for Determining Temperature and Emissivity[J];INFRARED TECHNOLOGY;1998-02
5 Shi Deheng (Dept.of Foundation,The First Aeronautical College of Air Force,Xinyang 464000) Chen Anjun (Dept.of Physics,Xinyang Teachers College,Xinyang 464000);An intelligent measurement instrument of specific radiance of high temperature object using laser in real time[J];LASER JOURNAL;1998-06
6 Shi Deheng Chen Yuke (Department of Foundation,The First Aeronautical College of Air force,Xinyang 464000);An intelligent measurement instrument of specific radiance and temperature of hightempera ture object using laser in real time[J];LASER JOURNAL;1999-03
7 Liu Tiean;Study of Taechnique in The Microscpic Measuring Temperature[J];Journal of Shenyang University;1994-04
8 Tian Guanggui (Kunming Institute of Technology);Some Problems about Temperature Measurement in Steel Rolling Process[J];Metallurgical Industry Automation;1989-05
9 Jiang Shichang;The Infrared Measuring Technology for Temperature[J];Process Automation Instrumentation;1996-04
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved