Several Methods to Reduce Transformer Inrush Current

CHEN Yan, CHEN Xiao-chuan, GAO Shi-bin(School of Electrical Engineering, Southwest Jiaotong University, Chengdu 610031, China)  
Large inrush current occurs when energizing unloaded transformer in power system, which provides unfavorable condition in transformer operation. Three methods are proposed in this paper to reduce inrush current: by controlled three-phase switching; by resistor insertion and by changing the distribution of coil winding. The three methods are proved to be effective both by the theoretical and practical considerations which all have advantages and disadvantages, but the feasibility of the former two methods is better.
【CateGory Index】: TM41
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 2 Hits
1 CUI Hengrong,GUO Congliang(Department of Electronic Science & Technology,University of Science and Technology of China,Hefei 230027,China);Identification of Transformer Inrush Current and Internal Fault Current Based on Wavelet Algorithm[J];Low Voltage Apparatus;2007-21
2 HUO Xian-jun (Power(Beijing) Product Certification Center Co., Ltd, Beijing 100011, China);Analysis and Countermeasures for Excitation Inrush at Making of Transformer[J];Jiangsu Electrical Apparatus;2007-06
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 ZHANG Xiu-mei,ZHOU Sheng-rong (Electrical Co.,Ltd.of Baotou Steel(group) Corporation,Baotou 014010,Nei Monggol,China);Phase-shifting of the Multi-impulse Converter Transformer[J];Science & Technology of Baotou Steel(Group) Corporation;2006-01
2 ZOU Wu, LI Dong?lin, XONG Lin?mei (Jiangxi Transformer Co., Ltd., Nanchang 330114, China);The Fault Analysis of Shifting Phase of Rectifier Transformer[J];Transformer;2001-01
3 XIN Cheng-shan (Northern Jiaotong University,Beijing100044,China);Further Analysis of Winding Current in Phase Shifting Rectifier Transformers[J];Transformer;2002-12
4 ZHENG Shao-zhong, GU Wen-xi, CHEN Jie, ZHENG Li-wei, LING Jiang (Tianjin Tebian Electric Apparatus Transformer Co.,Ltd., Tianjin 300112, China);Design and Calculation of Rectifier Transformer with Hexagon Phase Shift Winding[J];Transformer;2005-02
5 MENG Qingmin1 JIANG Lixin2(1. Shenyang Transformer Research Institute Shenyang 110179 China2. Baoding Tianwei Baobian Electric Co.Ltd. Baoding 071056 China);Optimal Design of Electromagnetic Calculation in Transformer Based on Object Oriented Technology[J];Transformer;2006-01
6 Fu Yang Lan Zhida Shanghai Institute of Electric Power,Shanghai 200090 Chen Heng Southeast University,Nanjing 210096;Simulation of Magnetizing Inrush Current in Three-Phase Transformer Considering Dynamic Magnetization Performance of Core[J];TRANSFORMER;1997-09
7 Su Tao1,2,Zan Xiaoshu1,2,Zhou Lixin2(1. Dep.of Automation,China University of Mining & Technology,Jiangsu Xuzhou 221008,China;2.Engineering Technology Research Center for Power Drive & Automatic Control of Jiangsu Province,Jiangsu Xuzhou 221004,China);Apply analog optocoupler HCNR201 to check voltages with high accuracy[J];Electrical Measurement & Instrumentation;2004-07
8 DUANXiongying*,ZOUJiyan,FANGChunen,CONGJiyuan( Dept. of Electr. and Electron Eng., Dalian Univ. of Technol., Dalian 116024, China );Synchronized control tactics of phasing vacuum switches when closing capacitor banks[J];Journal of Dalian University of Technology;2003-04
9 FANGChunen,ZOUJiyan*,DINGFuhua,DUANXiongying( Dept. of Electr. and Electronic Eng.,Dalian Univ. of Techonol.,Dalian 116024,China );Research on dielectric recovery of short gap arc in phasing vacuum switches[J];Journal of Dalian University of Technology;2003-05
10 ZHOU Yu-lan1, CHENG Xiao2 (1. China Electric Power Research Institute, Beijing 100085,China; 2. Electric Power Dispatching & Communication Center, SGCC, Beijing 100031,China);Problem Analysis of Protection Device in Nation-wide Power Grid in Operation in 2004[J];Electrical Equipment;2006-01
【Secondary References】
Chinese Journal Full-text Database 1 Hits
1 CHENG Xu,ZHANG Hao-ran (Henan Jiaozuo Power Supply Company,Jiaozuo 454150,China);Brief analysis and solution of the protection trip caused by no-load transformers' input[J];Power System Protection and Control;2009-19
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved