Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Chemical Analysis and Meterage》 2008-02
Add to Favorite Get Latest Update

DETERMINATION OF TRACE LEAD IN SPIRITS BY HYDRIDE GENERATION-ATOMIC FLUORESCENCE SPECTROMETRY

Tang Lianxian (Jinhua Measurement and Test Institute for Quality and Technique Supervision, Jinhua 321000, China)Wu Xiao(Jinhua City CHELBI Engineering Consulting Co.ltd, Jinhua 321000, China)Zheng Shaocheng(Zhejiang Normal University, Jinhua 321000, China)  
A method for determination of lead in spirits by hydride generation-atomic fluorescence spectrometry was established. The infection factors were studied, and the best test conditions were selected. The linearity range for the determination of lead was 0-20.0 μg/L, and the limit of detection was 1.0 μg/L. The recoveries were in the rang of 94.0%-108.0%. The relative standard deviations were 3.28%-4.03%(n=11).
【CateGory Index】: TS261.7;O657.31
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved