An Expert System for Vibration Diagnosis of the Hydroelectric Generating Set

Tang Mingxi Zhang Changqi  
A vibration diagnosis and consultation expert system for hydroelectric generating set based on knowledge base and the technique of the expert system is proposed. With knowledge of the vibration of the generating set, the vibration test, spectrum analysis and field experience of the operating personnel, this system is designed to work by inference. An inferential control program is developed with an architecture of the generating type of the expert system. The system is made up of three main parts, namely, the knowledge base, the library of algorithm program and the diagnosis Consultation program; The language of MACLISP is used and th esystem can be operated on an IBM-PC computer.
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 1 Hits
1 Yu Yin-zhang (South-East University), Wang Feng-quan, Cao Zu-qing.;An Hierarchic Model for Fuzzy Failure Diagnosis of Rotating Machinery[J];POWER ENGINEERING;1996-01
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 KANG Jin xing (The Engineering Institute, Air Force Engineering University,Xi′an 710038, China) ZHAO Wen zhen(State Key Laboratory for Mechanical Behavior of Material, Xi′an Jiaotong University, Xi′an 710049, China);Effect of WC on Cavitation Erosion Resistance of Copper-based and Nickel-based Coatings[J];Journal of Materials Engineering;2002-03
2 KANG Jin\|xing\+1, ZHAO Wen\|zhen\+2, XIAO Jie\+1 (1. The Engineering institute, Air Force Engineering University, Xi'an\ 710038, China; 2. State Key Laboratory for Mechanical Behavior of Material, Xi'an Jiaotong University, Xi'an\ 710049, China);Effect of WC on Cavitation Erosion Resistance of Spray Welding Coating of CuNiSiB Alloy Powder[J];Materials Science and Engineering;2002-01
3 MAO Shaobin(Sichuan Huaneng Kangding Hydroelectric Power Co Ltd,Chengdu 610000,China);Analysis and Consideration of Safe Operation and Maintenance of Hydropower Equipment[J];Hydropower Automation and Dam Monitoring;2008-02
4 ChengYuanchu(WuhanUniversityofHydraulic and Electric Engineering;Study on the Method ofFast ConvergenceforComputing Turbine Transients[J];LARGE ELECTRIC MACHINE AND HYDRAULIC TURBINE;1997-04
5 PENG Bing1,2,ZHOU Jianzhong1,FANG Rengcun1,XIANG Xiuqiao1,ZHANG Yongchuan1(1.Huazhong University of Science and Technology,Wuhan 430074,China;2.China Yangtze Power Co Ltd,Yichang 443002,China);Hydropower Generating Unit's Fault Diagnosis Based on Information Fusion[J];Automation of Electric Power Systems;2008-13
6 JIANG Jin-liang(Department of Information and Computing Science,Shanghai University of Electric Power, Shanghai200090, China);Fundamental Equations and Computational Methods of Compressible Flow in Tubes at the Hydraulic Transient in Pumped Storage Plants[J];Journal of Shanghai Institute & Electric Power;2003-04
7 GAO Jia-cheng~1, SUN Yu-lin~2 (1. College of Material Science and Engineering, Chongqing University, Chongqing 400044, China; 2. Dongfang Electrical Machinery Co.,Ltd., Deyang 618000, China);EROSION-CORROSION PREVENSION OF MATERIALS USED FOR HYDRAULIC TURBINE FLOW-PARTS[J];Corrosion & Protection;2004-08
8 Li Wenguang (Dept. of Hydraulic Mechinery Engineering);Simple Numerical Simulation of Air Bubbles Motion in Self Priming Centrifugal Pumps With Outer Recirculation[J];;1991-04
9 Li Rennian (Dept. of Hydraulic Machinery Engineering);Study and Analysis of Silt-laden Water Flow in Hydraulic Turbine[J];;1992-01
10 QI Xue-ye, LI Pei (College of Fluid Power and Control, Lanzhou Univ. of Tech., Lanzhou730050, China);Artificial intelligence and economic operation of hydropower stations[J];;2004-06
【Co-references】
Chinese Journal Full-text Database 3 Hits
1 Du Yongzuo,Hu Chongling,Zhang Chenguang;APPLICATION OF THE EXPERT SYSTEM IN DIAGNOSING THE FAULTS OF POWER PLANT FACILITIES[J];;1991-S1
2 Lu Zhong;FUZZY DIAGNOSIS FOR ROTOR'S FAULTS[J];;1991-01
3 Li Guisan Zhang Zhengsong (LiaoYang Petroleum-Chemical Institute Liaoyang, 111003)(Qinghua Univesity Beijing, 100084);An Investigation on the Attribution and Solving Strategy of the Fault diagnosis expert system for High Speed Rotating Machinery[J];Journal of Vibration,Measurement & Diagnosis;1993-03
【Secondary References】
Chinese Journal Full-text Database 4 Hits
1 Yang Ping1 ,Wu Jie1 ,Feng Yongxin2 1.South China U niversity of Technology,Guangzhou5 10 6 40 ,China 2 .Guangdong Power Test and Research Institute,Guangzhou 5 10 6 0 0 ,China;FUZZY FAULT DIAGNOSISSYSTEM FOR A200MW TURBO- GENERATOR SET[J];Automation of Electric Power Systems;2001-01
2 GU Shu qing, LI Chang song, HU Qiong (North China Electric Power Professional Technique Training Center, Beijing 102401, China);The Measurement of Roll-Machinery Vibration and Dynamic Date-Collect System[J];POWER ENGINEERING;2000-03
3 ZHANG Bide1,LI Ming2,ZHENG Gao1(1 Department of Electronicl Information and Electrical Engineering, Xihua University, Chengdu 610039, China;2 Department of mechanical engineering, Xihua University, Chengdu 610039, China);The Multiple-layer Fuzzy Model for Turbo-generator Vibration Faulty Diagnosis[J];Turbine Technology;2003-05
4 YANG Ping(Electric Power College,South China University of Technology,Guangzhou 510640,China);FAULT DIAGNOSIS SYSTEM FOR TURBO-GENERATOR SET BASED ON FOCUSING FUZZY COMPREHENSIVE EVALUATION[J];Journal of Vibration and Shock;2007-02
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved