Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Power System Protection and Control》 2010-03
Add to Favorite Get Latest Update

Scheme of the distance protection to avoid mal-operation in swing

LI Xiao-bin1,LIU Kai1,2,CHEN Ju-sheng1,XU Gang1,CHEN Shu-zhi1 (1. Dongfang Electronics Industry Co. Ltd,Yantai 264001,China; 2. School of Electrical Engineering,Xi'an Jiaotong University,Xi'an 710049,China)  
Through the analysis of the dynamic model of HV transmission line recorded data,this paper points out that the angle between two source potentials of both sides of the line maybe remain as 180°for a relatively long time,which would fail the current swing block methods. A method is presented in this paper to solve such a problem,the swing speed is measured by the two resistance element real-timely,and the delay time of the swing unblock criterion is adjusted real-timely according to the real-time swing speed. The method is validated by the dynamic model data,simulation result shows that the presented method will not mal-operate during swing.
【CateGory Index】: TM773
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 10 Hits
1 Zkou Zexin. Zhou Chunxia. Wang Shirong, Shen Xiaofan, Qiu Yufengdslectrical Power Research institute of China, Beijing 100085. China);SEVERAL PROBLEMS APPEARED IN DYNAMIC SIMULATION TESTS FOR MICROPROCESSOR-BASED TRANSMISSION LINE PROTECTIVE RELAYS[J];Automation of Electric Power Systems;2001-16
2 Lin Xiangning, Liu Pei, Feng Xingxue (Huazhong University of Science and Technology, Wuhan 430074, China) (Guangzhou Baiyun International Airport Co Ltd, Guangzhou 510000, China);THEORETICAL ANALYSIS OF THE SELF-ADAPTIVE BLOCKING CRITERION OF POWER SWINGS[J];Automation of Electric Power Systems;2004-06
3 GAO Peng , WANG Jian-quan , GAN De-qiang , HAN Zhen-xiang ( Zhejiang University, Hangzhou 310027, China) ( NARI-Relays Electric Co Ltd, Nanjing 211100, China);Review on Power System Out-of-step Separation[J];Automation of Electric Power Systems;2005-19
4 MAO Peng , DUAN Yu-qian , XU Yang , LI Xiao-bin Jiangsu Provincial Electric Power R & D Center, Nanjing 210036, China Southeast University, Nanjing 210096, China China Southern Power Grid Co Ltd, Guangzhou 510623, China Zhejiang University, Hangzhou 310027, China Yantai Dongfang Electronics Information Industry Co Ltd, Yantai 264001, China;Realization of Dynamic Instability Detecting Relay in High Voltage Line Protection Devices[J];Automation of Electric Power Systems;2006-02
5 XU Qing-qiang , SUONAN Jia-le , LIU Huan-zhang , XU Yang (Xi'an Jiaotong University, Xi'an 710049, China) (Jiangsu Electric Power Research Institute Corporation Limited, Nanjing 210036, China) (Huazhong Electric Power Dispatch &. Communication Bureau, Wuhan 430070, China);Fault Phase Selector for HV Transmission Line Protective Relaying Based on the Characteristic of the Arc Voltage Between Two Faulted Phases[J];Automation of Electric Power Systems;2006-04
6 BAI Yang, GAO Peng, SUN Guang-hui, CHEN Song-lin (NARI-Relays Electric Co Ltd, Nanjing 211100, China);Coordination of Out-of-step Separation Devices in China Southern Power Grid[J];Automation of Electric Power Systems;2006-07
7 YANG Haitao1, DING Maosheng2, SONG Xinli1, ZHANG Jun2(1. China Electric Power Research Institute, Beijing 100192, China; 2. Ningxia Electric Power Company, Yinchuan 750001, China);Analysis on Power System Dynamic Stability Mechanisms and Stabilizing Measures[J];Automation of Electric Power Systems;2008-14
8 Kong Fanpeng,Ge Yaozhong,Zhou Qinwu(Xi′an Jiaotong University);A NEW PRINCIPLE OF DISCRIMINATION BETWEEN POWER SWING AND SHORT CIRCUIT[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1995-04
9 Jin Huafeng; He Benteng(Zhejiang University, Hangzhou, 310027, China);SOME RESEARCH FOR DISCRIMINATING POWER SYSTEM OSCILLATION[J];RELAY;1999-02
10 LI Rui-sheng~1,SUONAN Jia-le~2 (1.XJ Electric Protection and Automation Business Department,Xuchang 461000,China;2.Xi'an Jiaotong University,Xi'an 710049,China);The special problems of 750 kV transmission line and its influences on relay protection[J];Relay;2006-03
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 Xiao Aunan;The character of high - frequency channel with YBX - 1 and CKF - 1 directional high - frequency proection.[J];Journal of Anhui Electric Power College for Staff;1999-04
2 ;A research overview on generation unit resynchronization[J];Anhui Electric Power;2006-04
3 CHEN Wu-jia1,ZHU Yong-hai2(1.Extra High Voltage Branch of Jiangxi Electric Company,Nanchang,Jiangxi 330006,China;2.Guangdong Tianlian Engineering Co.,Ltd.,Guangzhou,Guangdong 510600,China);Analysis of Current Transformer Saturation Characteristics Based on PSCAD[J];High Power Converter Technology;2009-01
4 YUAN Zhao-qiang,WU Qiang(College of Electrical Engineering and Information Science,China Three Gorges University,YiChang 443002,China);Method of Setting of the Self-adaptive Relay Protetction[J];Journal of Changsha University of Electric Power(Natural Science);2006-04
5 YANG Chang-hong,LIU Cheng-zhi,CHEN Qing-hua(College of electrical engineering,Southwest Jiaotong University,Chengdu 610031,China);Research on the ability of ultra-high voltage transmission line distance protection standing fault resistance influence[J];Journal of Electric Power Science and Technology;2007-03
6 NIE Hong-zhan,DAI Wu-chang,CHUI Shi (Northese China Electic Power Institute,Jilin City 132012);Analysis and Improvement of Triple-winding Transformer Low-voltage Side Backup-protection for Two-phase Fault[J];Journal of Northeast China Institute of Electric Power Engineering(Natural Science Edition);2003-04
7 LIN Jun, WEN Bu ying (Dept. of Electric Engineering, Fuzhou University, Fuzhou 350002, China);Accurate fault calculations for parallel power lines on same tower[J];Advanced Technology of Electrical Engineering and Energy;2004-02
8 LIN Jun(College of Electric Engineering, Fuzhou University, Fuzhou 350002, China);Accurate calculation for random faults of double circuit line on loop net[J];Advanced Technology of Electrical Engineering and Energy;2005-04
9 XIA Yi~1,LIU Jian-ming~2(1.China Electric Power Research Institute,Beijing 100085,China;2.China Electric Power Information Center,Beijing 100761,China);Effect of superconducting fault current limiters on power system protection and transient stability[J];Advanced Technology of Electrical Engineering and Energy;2007-02
10 Wu Lie1 Gu Bin2, 3 Tan Jiancheng2 (1. Wenzhou University Wenzhou 325027 China 2. Guangxi University Nanning 530004 China 3. Shaoxing College of Arts and Science Shaoxing 312000 China);A Fault Phase Selector for HV Transmission Line Protective Relaying Based on Power Increment[J];Transactions of China Electrotechnical Society;2008-06
China Proceedings of conference Full-text Database 7 Hits
1 LI Yi-quan, HE Ben-teng (Zhejiang University, Hangzhou 310027, China);IDENTIFICATION OF FOUND AMENTAL WAVE IN CVT TRENSIENT PROCESS BASED ON EXPANEDED PRONY ALGORITHM[A];[C];2005
2 Wang Wenxiong He Benteng (Nanjing Electric Power Automation Equipment General Factory 21003) ( Zhejiang University Hangzhou 310027 China);The Unbalance Output Of Digital Negative Sequence Strainer[A];[C];2005
3 ZHANG Hua LIU Wanshun ZHENG Tao YANG Qing(Key Laboratory of Power System Protection and Dynamic Security Monitoring and Control under Ministry of Education (North China Electric Power University),Changping District,Beijing 102206,China);STUDY ON THE DISDINGUISHING FAULT IN OSCILLATION BASED ON THE ALGORITHM OF COMPREHENSIVE VECTOR AND MORPHOLOGY[A];[C];2006
4 PAN Zhencun~1 CONG Wei~1 SU Yongzhi~(1,2) DING Lei~1(1.School of Electric Eng.,Shandong University,Jinan,Shandong,250061;2.Jinan Electric Power Utility,Jinan,Shandong,250002);Some proposals on the relay protection of distribution feeder[A];[C];2006
5 LIU Kai~(1,2) LI Xiao-bin~2 LIU Shi-ming~2 SUONAN Jia-le~1(1.Xi'an Jiaotong University,Xi'an 710049,china;2.Yantai Dongfang Electroric Company);New Method to Improve the Performance of HV Transmission Line Protective Relaying Phase Selector[A];[C];2006
6 LIU Kai~(1,2),SUONAN Jia-le~2,KANG Xiao-ning~2 (1.Yantai Dongfang Electronics Information Industry Co.L,Yantai 264001,China; 2.Xi'an Jiaotong University Electrical Engineering Department,Xi'an 710049,China);A Novel Transmission Line Pilot Protection Based on integrated impedance[A];[C];2008
7 WANG Xiang-ping East China Electric Power Design Institute,Shanghai 200063,China;Study on auxiliary function scheme of line protection[A];[C];2008
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 Xie Baoyan (Electric Power Research Institute,P.R.C.);ANALYSIS & DISCUSSIONS ON THE SWING-BLOCKING SCHEME FOR SOME FOREIGN-MADE LINE PROTECTION EQUIPMENT[J];Automation of Electric Power Systems;1989-04
2 Shen Guorong, Deng Shaolong, Zhu Shengshi (Nanjing Automation Research Institute);THE NEW PRINCIPLE OF DISCRIMINATION BETWEEN POWER SWING AND SHORT CIRCUIT[J];Automation of Electric Power Systems;1990-01
3 Li Xingyuan1, Li Li2(1. Sichuan University. Chengdu 610065, China)(2. University of Bath. UK);SURVEY OF THE EMERGENCY CONTROL IN POWER SYSTEMS[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-09
4 Zkou Zexin. Zhou Chunxia. Wang Shirong, Shen Xiaofan, Qiu Yufengdslectrical Power Research institute of China, Beijing 100085. China);SEVERAL PROBLEMS APPEARED IN DYNAMIC SIMULATION TESTS FOR MICROPROCESSOR-BASED TRANSMISSION LINE PROTECTIVE RELAYS[J];Automation of Electric Power Systems;2001-16
5 Suonan Jiale 1, Xu Qingqiang 1, Song Guobing 1, Li Ruisheng 2, Ge Yaozhong 1 (1. Xi'an Jiaotong University, Xi'an 710049, China) (2. Xuchang Relay Research Institute, Xuchang 461000, China);ANALYSIS ON THE OPERATING CHARACTERISTIC OF THE SEQUENCE-COMPONENT FAULT PHASE SELECTOR DURING POWER SWINGS[J];Automation of Electric Power Systems;2003-02
6 Xu Qingqiang 1, Suonan Jiale 1, Song Guobing 1, Yang Chunming 2, Yang Lifan 2 (1. Xi'an Jiaotong University, Xi'an 710049, China) (2. Yantai Dongfang Electronic Information Industry Co Ltd, Yantai 264001, China)[KH2D];A FAULT PHASE SELECTOR FOR TRANSMISSION LINE PROTECTIVE RELAYING USING CURRENT FAULT COMPONENTS[J];Automation of Electric Power Systems;2003-07
7 Zheng Tao, Liu Wanshun, Yang Qixun, Yin Zhiliang (North China Electric Power University, Beijing 100085, China);A NEW PHASE SELECTOR BASED ON FAULT SEQUENCE COMPONENTS AND FUZZY LOGIC THEORY[J];Automation of Electric Power Systems;2003-12
8 Zong Hongliang, Sun Guanghui, Liu Zhi, Wang Rong (NARI RELAYS Co. Ltd., Nanjing 210003, China);COORDINATION OF OUT-OF-STEP PROTECTION EQUIPMENT IN LARGE POWER SYSTEMS[J];Automation of Electric Power Systems;2003-22
9 Gao Peng, Wang Jianquan, Zhou Wenping(Zhejiang University, Hangzhou 310027, China)(Guodian Nanjing Automation Co Ltd, Nanjing 210003, China);IMPROVEMENT OF THE APPARENT IMPEDANCE ANGLE SEPARATION CRITERION[J];Automation of Electric Power Systems;2004-24
10 CHEN Zhao-hui, HUANG Shao-feng , TAO Hui-liang , YANG Qi-xun(North China Electric Power University, Beijing 102206, China)(Beijing Sifang Automation Co LTD, Beijing 100085, China);Research on the New Phase Selector Based on Impedance Measurement[J];Automation of Electric Power Systems;2005-03
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved