Fault line selection of resonant grounding system based on the characteristics of charge-voltage in the transient zero sequence and support vector machine

ZHANG Shu,HE Zheng-you,WANG Qi,LIN Sheng(School of Electrical Engineering,Southwest Jiaotong University,Chengdu 610031,China)  
A method of fault line selection in the resonant grounding system of distribution network based on the characteristics of the charge-voltage(Q-U) in the transient zero sequence and support vector machine(SVM) is proposed.In order to solve the problem that methods of fault line selection in the distribution network are unreliable,this paper researches the characteristic relationship between charge and voltage in the zero sequence from the point of the fault transients generated by phase-to-earth fault.With the classification algorithm of support vector machine that supports for small sample and taking the correlation coefficients of the charge and voltage in the zero sequence of every feeder as the characteristic input,a set of processes of the fault line selection in the distribution network based on the characteristics of the charge and voltage in the zero sequence is established.A 35 kV simulation model of resonant grounding system is established in the PSCAD/EMTDC.A large number of simulation results show that the method is not affected by fault distance and fault time.Especially,it is still be able to select fault line correctly in the condition of high impedance and arc fault.
【CateGory Index】: TM862
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 10 Hits
1 DAI Ming,HE Zheng-you,ZHAO Jing,JIA Yong (School of Electrical Engineering,Southwest Jiaotong University,Chengdu 610031,Sichuan Province,China);A Method to Locate Disturbance Source due to Capacitor Switching in Distribution Network Based on Integration of Wavelet Transform With Support Vector Machine[J];Power System Technology;2010-06
2 LIANG Rui,WANG Yangyang(School of Information and Electrical Engineering,China University of Mining and Technology, Xuzhou 221008,Jiangsu Province,China);An Intuitionistic Fuzzy Set Based Synthetical Approach of Faulty Line Selection for Single-Phase Ground Fault[J];Power System Technology;2011-11
3 ZHANG Hui-fen1,PAN Zhen-cun2,ZHANG Fan2(1.School of Control Science and Engineering,Jinan University,Jinan 250022,China;2.School of Electrical Engineering,Shandong University,Jinan 250061,China);Earth Fault Line Selection in Distribution System by the Rough Set Theory[J];High Voltage Engineering;2008-04
4 ZHANG Bao-hui, ZHAO Hui-mei, ZHANG Wen-hao,XU Jing-dong (Xi’an Jiaotong University, Xi’an 710049, China);Faulty line selection by comparing the amplitudes of transient zero sequence current in the special frequency band for power distribution networks[J];Power System Protection and Control;2008-13
5 PANG Qing-le1,2,CHEN Sheng-yin3(1.School of Information and Electronic Engineering,Shandong Institute of Business and Technology,Yantai 264005,China;2.College of Computer Science,Liaocheng University,Liaocheng 252059,China;3.Jingzhou Electric Power Supply Company,Jingzhou 434000,China);Artificial immune algorithm based faulty line detection method for indirectly grounding power system[J];Power System Protection and Control;2009-24
6 ZHOU Deng-deng,LIU Zhi-gang,HU Fei,BAI Wei-li (College of Electrical Engineering,Southwest Jiaotong University,Chengdu 610031,China);A new method for fault line selection based on wavelet de-noising and transient current energy grouping comparison in ineffective grounding system[J];Power System Protection and Control;2010-07
7 JIA Qing-quan 1, LIU Lian-guang 1, YANG Yi-han 1, SONG Jia-hua 2 (1.North China Electric Power University, Beijing 100085,China; 2.Northeast China Institute of Electric Power Engineering, Jilin 132012,China);ABRUPT CHANGE DETECTION WITH WAVELET FOR SMALL CURRENT FAULT RELAYING[J];Proceedings of the Csee;2001-10
8 SHU Hong-chun, PENG Shi-xin, LI Bin, ZHAO Xing-bing (Faculty of Electric Power Engineering, Kunming University of Science and Technology, Kunming 650051,Yunnan Province, China);A New Approach to Detect Fault Line in Resonant Earthed System Using Simulation After Test[J];Proceedings of the CSEE;2008-16
9 ZHANG Jun,HE Zhengyou,JIA Yong(Department of Electrical Engineering,Southwest Jiaotong University,Chengdu 610031,Sichuan Province,China);Fault Line Identification Approach Based on S-transform[J];Proceedings of the CSEE;2011-10
10 LU Bo,WEI Xun-kai,BI Du-yan(The Engineering Institute,Air Force Engineering University,Xi'an 710038);Applications of Support Vector Machines in Classification[J];Journal of Image and Graphics;2005-08
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 ;Survey of the Mthods of Fault Line Slection Based on Small Current Grounding System of Distribution Network[J];Anhui Electric Power;2010-02
2 LI Yuan1,LIAO Hai-bin2(1.Network Information Center,Anhui Science and Technology University,Fengyang 233100,China;2.School of Electronic Information,Wuhan University,Wuhan 430079,China);A New Scheme to Faulty Line Selection Based on Wavelet Packets Technology and Correlation Analysis[J];Journal of Anhui Science and Technology University;2011-04
3 Wang Ran1,Yang Daojun2(1.Maanshan Institute of Environmental Sciences,Maanshan 243000,China;2.Sinosteel Maanshan Institute of Mining Research co.,ltd,Maanshan 243000,China);The Research on the Level of Eutrophication of Chaohu Lake Based On the Support Vector Machine[J];Environmental Science and Management;2011-05
4 YANG Li-nan,ZHOU Min(1.Daxing Power Supply Company,Beijing Electric Power Corporation,Beijing 102600;2.Hengyang Power Supply Company,Hunan Electric Power Corporation,Hunan Hengyang 421001);Fault Line Selection for Distribution Network Based On Improved Hilbert-Huang Transform[J];Journal of Northeast Dianli University;2011-02
5 WANG Ning1,JIA Qing-quan1, PANG Hai-yan2 (Electrical Engineering College of Yanshan University Qinhuangdao 066004 Hebei, China;2.Heilongjiang Tieli Heat and Power Co., Tieli 152500 Heilongjiang,China);Virtual Instrument Based Single Phase Fault Detecting Device for Power Distribution Networks[J];Electrical Measurement & Instrumentation;2006-01
6 YANG Lin-xia1,LIU Dan2(1.Department of Electrical Engineering,Shaanxi University of Technology,Hanzhong 723003,Shanxi,China.2.Liaoning Yingkou Power Supply Company,Yingkou 115000,Liaoning,China);Research on Faulted Feeder Identification of Transient Information Based on Wavelet Theory[J];Electrical Measurement & Instrumentation;2010-08
7 ZHAO Jian-wen,HOU Yuan-bin(School of Elec.and Control Eng.,Xi’an University of Science and Technology,Xi’an 710054,China);Rapid leakage identification of coal mine low voltage distribution network based on signal distance degree[J];Advanced Technology of Electrical Engineering and Energy;2011-01
8 Zhu Ke1 Pei Younan1 Chen Chen2 Xu Wenyuan1 (1. Shandong University Jinan 250061 China 2. Dongying Power Supply Corporation Dongying 257091 China);Self-Adaptable and Current Controllable Faulted Line Identification Scheme[J];Transactions of China Electrotechnical Society;2009-08
9 Shu Hongchun1 Peng Shixin2 (1. Kunming University of Science and Technology Kunming 650051 China 2. Kunming Power Supply Bureau in Yunnan Power Grid Kunming 650011 China);A Fault Line Detection Algorithm for Distribution Network of Overhead Line and Underground Cable Mixed Lines Using S-Transform Energy From Short Window Data[J];Transactions of China Electrotechnical Society;2009-10
10 Zhang Haiping He Zhengyou Zhang Jun (Southwest Jiaotong University Chengdu 610031 China);A Fault Line Detection Method for Indirectly Grounding Power System Based on Quantum Neural Network and Evidence Fusion[J];Transactions of China Electrotechnical Society;2009-12
China Proceedings of conference Full-text Database 3 Hits
1 LIU Lian-guang ZHANG Jian-hua North China Electric Power University(Beijing),Beijing,102206,China;RESEARCH ON GIC'S EFFECTS ON POWER SYSTEM AND ITS MONITORING[A];[C];2003
2 ZHANG Tong-zhou (Huaian Power Co.,Huaian 223003 ,Jiangsu Province,China);The Method Study of Selecting Line With Single Phase Grounded Fault Based on Wavelet and αβ Space Parameter[A];[C];2006
3 PANG Qing-le, SUN Tong-jing, ZHONG Mai-ying ( School of Control Science and Engineering, Shandong University, Jinan 250061, Shandong Province, China; Department of Physics, Liaocheng University, Liaocheng 252059, Shandong Province, China);New Criterion of Faulty Line Detection for Distribution Networks Based on Wavelet Packet Analysis[A];[C];2006
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 Geng Yunling1, 2 Wang Qun1 He Yigang2 (1. National University of Defense and Technology Changsha 410112 China 2. Hunan University Changsha 410082 China);Detection,Location and Classification of Power Quality Disturbances Based on Phase of Complex Wavelet[J];Transactions of China Electrotechnical Society;2006-08
2 Shu Hongchun1 Peng Shixin2 (1. Kunming University of Science and Technology Kunming 650051 China 2. Kunming Power Supply Bureau in Yunnan Power Grid Kunming 650011 China);A Fault Line Detection Algorithm for Distribution Network of Overhead Line and Underground Cable Mixed Lines Using S-Transform Energy From Short Window Data[J];Transactions of China Electrotechnical Society;2009-10
3 Zhang Haiping He Zhengyou Zhang Jun (Southwest Jiaotong University Chengdu 610031 China);A Fault Line Detection Method for Indirectly Grounding Power System Based on Quantum Neural Network and Evidence Fusion[J];Transactions of China Electrotechnical Society;2009-12
4 Shu Hongchun 1, Xao Bai 2 (1. Kunming University of Science and Technology, Kunming 650051, China) (2. Northeast Institution of Electric Power Engineering, Jilin 132012, China);A TRANSIENT-BASED STUDY OF FAULT LINE SELECTION FOR SINGLE-PHASE TO GROUND FAULTS ON DISTRIBUTION SYSTEM[J];Automation of Electric Power Systems;2002-21
5 Xue Yongduan 1, Feng Zuren 1, Xu Bingyin 2, Chen Yu 2, Li Jing 2 (1. Xi'an Jiaotong University, Xi'an 710049, China; 2. Shandong Kehui Electric Co Ltd, Zibo 255031, China);EARTH FAULT PROTECTION IN NON-SOLIDLY EARTHED NETWORK BASED ON TRANSIENT ZERO SEQUENCE CURRENT COMPARISON[J];Automation of Electric Power Systems;2003-09
6 Chen Jiongcong, Qi Zheng, Yang Qixun (North China Electric Power University, Beijing 102206, China);A FAULT LINE DETECTION DEVICE FOR THE NON-SOLIDLY GROUNDED SYSTEM BASED ON FUZZY SETS THEORY[J];Automation of Electric Power Systems;2004-08
7 Qi Zheng, Yang Yihan (North China Electric Power University, Beijing 102206, China);ANALYSIS OF THCHNOLOGY OF FAULT LINE SELECTION FOR SINGLE-PHASE-TO-EARTH FAULTS IN NEUTRAL POINT NON-EFFECTIVELY GROUNDED SYSTEM[J];Automation of Electric Power Systems;2004-14
8 Xue Yongduan, Chen Yu, Xi Bingyin, Li Jing, Xiong Lixin (Kehui Electric Co Ltd, Zibo 255031, China; Xi'an Jiaotong University, Xi'an 710049, China);CHARACTERISTIC TRANSIENT BASED MONITORING SYSTEM FOR EARTH FAULT IN NON-SOLIDLY EARTHED NETWORK[J];Automation of Electric Power Systems;2004-24
9 SHU Hong-chun , LIU Juan, SI Da-jun, ZHANG Jie (Kunming University of Science and Technology, Kunming 650051, China) (Harbin Institute of Technology, Harbin 150001, China);New Adaptive Method for Fault Line Selection in Non-solidly Grounded System[J];Automation of Electric Power Systems;2005-13
10 ZHANG Fan , PAN Zhen-cun , ZHANG Hui-fen , XU Ai-dong , SONG Li-kun (Shandong University, Jinan 250061, China) (Shandong Electric Power Engineering Consulting Institute, Jinan 250100, China) (Anqiu Electric Power Supply Company, Anqiu 262100, China);New Criterion of Fault Line Selection in Non-solidly Earthed Network Based on the Maximum of Zero Sequence Transient Current[J];Automation of Electric Power Systems;2006-04
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved