Reliability modeling of battery energy storage system and its effect on the reliability of distribution system

ZHONG Yu-feng;HUANG Min-xiang;QIANG Ding-jian;College of Electrical Engineering, Zhejiang University;  
The reliability and operation strategy of battery energy storage system(BESS) are important to the reliability of power system. Based on analyzing the structure of two-stage grid-connected BESS, the reliability model of grid-connected BESS is established using the state space method. Then the reliability indices of BESS can be acquired. Reliability evaluation is made on a distribution system by using the software kits RAMSES, while allocating BESS in different conditions. Integrated analysis of the reliability of BESS accessing the distribution system in charge and discharge modes shows that the reliability effect of BESS is related to such factors as the load rate of the area which BESS is connected to, the reliability of the connected bus, and so on. When in the optimal allocation, BESS can improve the reliability of distribution system significantly.
【CateGory Index】: TM912;TM72
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 10 Hits
1 DING Ming,XU Ningzhou,BI Rui,CHEN Zinian,LUO Yaqiao,SONG Zhuo(1.Anhui New Energy Utilization and Energy Saving Laboratory,Hefei University of Technology,Hefei 230009,China; 2.Electrical Power Research Institute of Anhui Power Company,Hefei 230022,China);Modeling and Comparative Study on Multiple Battery Energy Storage Systems[J];Automation of Electric Power Systems;2011-15
2 XU Guofeng1,HUANG Minxiang1,HAN Hui1,2,DING Xiaoyu3(1.College of Electrical Engineering,Zhejiang University,Hangzhou 310027,China; 2.Yuhang Electric Power Bureau,Hangzhou 311100,China; 3.Zhejiang Provincial Electric Power Design Institute,Hangzhou 310014,China);Reliability adequacy evaluation based on RAMSES for UHV power grid[J];Electric Power Automation Equipment;2012-06
3 WANG Jian,LIU Tianqi,LI Xingyuan(School of Electrical Engineering and Information,Sichuan University,Chengdu 610065,Sichuan Province,China);Influences of Connecting Wind Farms and Energy Storage Devices to Power Grid on Reliability of Power Generation and Transmission System[J];Power System Technology;2011-05
4 MENG Hongnian,XIE Kaigui(State Key Laboratory of Power Transmission Equipment & System Security and New Technology(Chongqing University),Shapingba District,Chongqing 400044,China);Wind Farm Reliability Evaluation Considering Operation Characteristics of Battery Energy Storage Devices[J];Power System Technology;2012-06
5 JIA Hong-xin1,HE Wei-guo2,Zhang Yu2,FU Yang1(1.Shanghai University of Electric Power,Shanghai 200090,China;2.Technology & Development Center,SMEPC,Shanghai 200025,China);Installation and application of distributed NAS energy storage systems in USA[J];East China Electric Power;2009-12
6 LI Guo-jie1,TANG Zhi-wei2,NIE Hong-zhan2,TAN Jing1(1.State Key Laboratory of Power System,Dept of Electrical Engineering,Tsinghua University,Beijing 100084,China;2.Northeast Dianli University,Jilin 132012,China);Modelling and controlling of vanadium redox flow battery to smooth wind power fluctuations[J];Power System Protection and Control;2010-22
7 ZHOU Lin,HUANG Yong,GUO Ke,FENG Yu(State Key Laboratory of Power Transmission Equipment & System Security and New Technology,Chongqing University,Chongqing 400030,China);A survey of energy storage technology for micro grid[J];Power System Protection and Control;2011-07
8 XIE Kai-gui,WANG An,HU Bo(State Key Laboratory of Power Transmission Equipment & System Security and New Technology(Chongqing University),Chongqing 400044,China);Reliability evaluation of wind-diesel-storage hybrid system considering energy storage system operating strategies[J];Power System Protection and Control;2012-09
9 JIA Xudong1,HAN Weiqiang1,LI Zhanying2,LU Zhigang1,LIU Yi1,CHEN Man3,DONG Zheng3,ZHAO Guiwen3(1.Electric Power Research Institude,CSG,Guangzhou 510080,China;2.The Production & Technology Department of China Southern Power Grid,Guangzhou 510623,China;3.CSG Power Genertation Company,Guangzhou 510630,China);RTDS Research of Battery Energy Storage System in Shenzhen Baoqing Station[J];Southern Power System Technology;2011-06
10 WU Wen-xuan (Fujian Electric Power Research Institute, Fuzhou 350007, China);Study on configuration scheme of bulk battery energy storage plants’ protection[J];Power System Protection and Control;2012-18
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 QIU Guangwei1,LIU Ping2,ZENG Lecai3,LIAO Wenjun3,LIU Xinkuan2(1 School of Mechanical Engineering,University of Shanghai for Science and Technology,Shanghai 200093; 2 School of Materials Science and Engineering,University of Shanghai for Science and Technology, Shanghai 200093;3 Shanghai Electric Group Co.,Ltd.Central Academe,Shanghai 200070);Development of the Sodium-Sulfur Battery[J];Materials Review;2011-21
2 YAN Zhimin1,WANG Chengmin1,LIAN Hongbo2,YI Tao1,SHI Zhixiong3,ZHANG Yu3(1.School of Electronic Information and Electrical Engineering,Shanghai Jiaotong University,Shanghai 200240,China; 2.Songjiang Power Supply Branch of Shanghai Electric Power Company,Shanghai 201600,China; 3.Shanghai Electric Power Company,Shanghai 200122,China);Capacity Plan of Battery Energy Storage System in User Side Considering Power Outage Cost[J];Automation of Electric Power Systems;2012-11
3 YAO Jun,CHEN Xiyin,XIA Xianfeng,LIAO Yong,HUANG Song(State Key Laboratory of Power Transmission Equipments & System Security and New Technology, Chongqing University,Chongqing 400044,China);A Low Voltage Ride-through Control Strategy for Direct-driven Permanent Magnet Wind Power Generation System with Flywheel Energy Storage Unit[J];Automation of Electric Power Systems;2012-13
4 LI Minghui1,LI Guoqing1,WANG He1,BAI Yangsen2,ZHANG Yang3 (1.Northeast Dianli University,Jilin 132012,China;2.Zhengzhou Xinli Power Company Limited,Kaifeng 450081,China;3.North China University of Conservancy and Electric Power,Zhengzhou 450011,China);Modeling of Micro-Grid and Simulation of Micro-Grid Paralleling Control[J];Low Voltage Apparatus;2012-08
5 LU Ji-ping1,ZHU San-li1,HAN Tao1,LV Dong2,LIU Lei2 (1.State Key Laboratory of Power Transmission Equipment & System Security and New Technology Chongqing University,Chongqing 400044,P.R. China;2.Chongqing Urban Power Supply Bureau, Chongqing Electric Power Company, Chongqing 400013, P.R. China);Analysis of reasonable wind farm energy storage capacity range[J];Journal of Chongqing University;2010-08
6 WEI Zeng-fu1,ZHENG Jin2 (1.Electric Power Research Inst.of Guangdong Power Grid Corp.,Guangzhou,Guangdong 510080,China;2.Guangdong Electric Power Design Inst.,Guangzhou,Guangdong 510663,China);Energy Storage Techniques Applied in Smart Grid[J];Guangdong Electric Power;2010-11
7 JIN Wentao, MA Huimeng, XIE Zhijia (China Electric Power Research Institute, Beijing 100192, China);Wind Power Smoothing Control Strategy of Battery Energy Storage System[J];Electric Power Construction;2012-07
8 Xiao Shuoshuang Yin Zhongdong State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing 102206;Grid Connected Problems of Large Capacity Wind Farm Caused by Wind Speed[J];Electrical Engineering;2012-08
9 XIE Jiao,RUAN Xiao-li,LI Yu-long,HU Yun-cheng Central Research Academy of DEC,611731,Chengdu,China;Study of the Li-ion Battery Pack Consistency and Influence Factor[J];Dongfang Electric Review;2012-03
10 ZHAO Biao1,YU Qingguang1,WANG Liwen1,XIAO Yi2(1.Department of Electrical Engineering,Tsinghua University,Beijing 100084,China; 2.Dispatching and Communication Center,Hubei Electric Power Company,Wuhan 430077,China);Parallel Grid-connected System of Non-master-slave and Current-sharing Battery Energy Storage[J];Automation of Electric Power Systems;2012-21
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 Wu Yichun Ding Ming Li Shenghu (Hefei University of Technology Hefei 230009 China);Reliability Assessment of Wind Farms in Generation and Transmission Systems[J];Transactions of China Electrotechnical Society;2004-11
2 ZHAO Li-hua,GUO Xiang-guo,GAO Jin-qiang (Central Southern China Electric Power Design Institute,Wuhan 430071,China);1000kV Main Electrical Connection Design[J];Electric Power Construction;2010-04
3 Cheng Lin,Guo Yongji Tsinghua University,Beijing 10 0 0 84,China;NEW ALGORITHM OF ADEQUACY AND SECURITY EVALUATION FOR BULK POWER SYSTEM[J];Automation of Electric Power Systems;2001-19
4 LEI Ya-zhou , Gordon LIGHTBODY ( ESB National Grid, Ireland; University College Cork, Ireland);Wind Energy and Electricity Market[J];Automation of Electric Power Systems;2005-10
5 WEN Ji-feng, CHEN Song-lin, LI Hai-ying, ZHANG Hong-bo, LIU Wei NARI-Relays Electric Co Ltd, Nanjing 211100, China;Configuration and Application of AC Filter Protection[J];Automation of Electric Power Systems;2006-02
6 LU Zongxiang~1 WANG Caixia~1 MIN Yong~1 ZHOU Shuangxi~1 Lii Jinxiang~2 WANG Yunbo~2 1.State Key Laboratory of Power Systems,Department of Electrical Engineering,Tsinghua University,Beijing 100084,China 2.Liaoning Gaoke Energy Group,Shenyang 110141,China;Overview on Microgrid Research[J];Automation of Electric Power Systems;2007-19
7 LIU Changjin,HU Changsheng,LI Xiao,CHEN Min,XU Dehong(Zhejiang University,Hangzhou 310027,China);Design of SMES Control System for Smoothing Power Fluctuations in Wind Farms[J];Automation of Electric Power Systems;2008-16
8 GUO Li,WANG Chengshan(Key Laboratory of Power System Simulation and Control of Ministry of Education,Tianjin University,Tianjin 300072,China);Dynamical Simulation on MicroGrid with Different Types of Distributed Generations[J];Automation of Electric Power Systems;2009-02
9 JIN Yiding,SONG Qiang,LIU Wenhua(Tsinghua University,Beijing 100084,China);Nonlinear Controller for Battery Energy Storage System[J];Automation of Electric Power Systems;2009-07
10 CHEN Wei1,SHI Jing1,REN Li1,TANG Yuejin1,SHI Yanhui2(1.Huazhong University of Science and Technology,Wuhan 430074,China;2.State Grid Electric Power Research Institute(Wuhan),Wuhan 430074,China);Composite Usage of Muti-type Energy Storage Technologies in Microgrid[J];Automation of Electric Power Systems;2010-01
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved