A novel frequency band self-adaptive selection method of fault line selection in distribution network

YANG Jianxiang;CHANG Zhongxue;DOU Minna;WANG Xiaobo;Xi'an University of Science and Technology;School of Electrical Engineering, Xi'an Jiaotong University;  
In the non-solid earthed network fault line selection, nowadays the frequency band selection method is based on special frequency band(SFB). However, this method is liable to be influenced by the distribution network operation type and line parameters. To overcome the disadvantages, a new selection method of frequency band based on matrix pencil algorithm is proposed. In ungrounded distribution network, the minimum frequency is 0 Hz, in compensated distribution network, the minimum frequency is 150 Hz. The maximum frequency of frequency band is determined by the way as follows: first the common frequencies and phases of all line transient zero sequence current are extracted by the matrix pencil method. Then the maximum frequency that meets a certain relationship is found and the maximum frequency is the maximum of the frequency band. The simulation on PSCAD and the recording data analysis verify that the method proposed is effective. The method is hopeful to improve the accuracy of the fault line selection.
【CateGory Index】: TM862
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 10 Hits
1 XUE Yongduan1,XU Bingyin1 ,DU Jingyuan2 (1. Shandong University of Technology, Zibo 255049, China; 2. Shandong Jinan Power Supply Company, Jinan 250012, China);The Technology Analysis of Earth Fault Protection in Resonant Grounded System[J];Electrical Equipment;2007-11
2 Xue Yongduan 1, Feng Zuren 1, Xu Bingyin 2, Chen Yu 2, Li Jing 2 (1. Xi'an Jiaotong University, Xi'an 710049, China; 2. Shandong Kehui Electric Co Ltd, Zibo 255031, China);EARTH FAULT PROTECTION IN NON-SOLIDLY EARTHED NETWORK BASED ON TRANSIENT ZERO SEQUENCE CURRENT COMPARISON[J];Automation of Electric Power Systems;2003-09
3 Suonan Jiale, Zhang Chao, Wang Shugang (Xi'an Jiaotong University, Xi'an 710049, China);FAULT LINE SELECTION IN THE NON-SOLID EARTHED NETWORK BASED ON THE MODEL IDENTIFICATION METHOD[J];Automation of Electric Power Systems;2004-19
4 KANG Xiaoning,LIU Xin,SUONAN Jiale,MA Chao,WANG Chenqing,YANG Liming (School of Electrical Engineering,Xi'an Jiaotong University,Xi'an 710049,China);New Method for Fault Line Selection in Non-solidly Grounded System Based on Matrix Pencil Method[J];Automation of Electric Power Systems;2012-12
5 WANG Wei,JIAO Yan-jun(School of Electrical and Electronic Engineering,North China Electric Power University,Baoding 071003,Hebei Province,China);Application of Characteristic Components of Transient Signal in Grounded Wire Detection of Ineffectively Earthed Distribution Systems[J];Power System Technology;2008-04
6 ZHANG Zhongxiao,MIAO Shihong,LIN Xiangning,LIU pei(School of Electrical & Electronic Engineering,Huazhong University of Science and Technology, Wuhan 430074,Hubei Province,China);A New Adaptive Faulty Line Detection Approach Based on Reconstruction of Multi-band Components for Small Current Neutral Grounding System[J];Power System Technology;2011-09
7 LI Ye-bai1,TANG Ke-yi1,ZHANG Xiao-xiao1,YIN Kai2,LIU Hao2(1.Changxing County Power Company,Changxing 313100,China;2.Tianjin Tianda Qiushi Electric Power High Technology Co.,Ltd.,Tianjin 300384,China);Research and Application of Small Current Grounding Line Selection Device Based on Wavelet Packet Principle[J];Proceedings of the Chinese Society of Universities for Electric Power System and its Automation;2013-02
8 KANG Xiaoning;QU Yajun;JIAO Zaibin;LI Shaodi;WANG Donghui;NING Rong;School of Electrical Engineering,Xi'an Jiaotong University;Shaanxi Regional Electric Power Design Co.Ltd.;;Power-frequency Phasor Extraction Based on Least-square Matrix Pencil Algorithm[J];Automation of Electric Power Systems;2014-21
9 XUE Yongduan;ZHANG Qiufeng;YAN Tingchun;XU Bingyin;College of Information and Control Engineering,China University of Petroleum (East China);Shandong Kehui Power Automation Co.Ltd.;Research Center for Smart Grid,Shandong University of Technology;;Faulty Feeder Identification Based on Combined Transient and Power-frequency Components in Resonant Grounded Systems[J];Automation of Electric Power Systems;2014-24
10 ZHANG Bao-hui, ZHAO Hui-mei, ZHANG Wen-hao,XU Jing-dong (Xi’an Jiaotong University, Xi’an 710049, China);Faulty line selection by comparing the amplitudes of transient zero sequence current in the special frequency band for power distribution networks[J];Power System Protection and Control;2008-13
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 LI Yuan1,LIAO Hai-bin2(1.Network Information Center,Anhui Science and Technology University,Fengyang 233100,China;2.School of Electronic Information,Wuhan University,Wuhan 430079,China);A New Scheme to Faulty Line Selection Based on Wavelet Packets Technology and Correlation Analysis[J];Journal of Anhui Science and Technology University;2011-04
2 XU Zhi-qiang LIU Ming-guang LI Na HAO Wei-hua (School of Electrical Engineering,Beijing Jiaotong University,Beijing 100044,China);Study on Fusion Algorithm of Fault Diagnosis for Railway Power Line[J];Journal of Beijing Jiaotong University;2007-02
3 LI Juan~1,JIAO Shao-hua~2 (1.Department of Computer science & Automation, Beijing Institute of Machinery, Beijing 100085,China;2.Beijing Si fang Automation Co Ltd,Beijing 100085,China);A new principle of single-phase-earth fault detection based on distribution automation platform[J];Journal of Beijing Institute of Machinery;2005-02
4 XIONG Zhi-wei CAI Jin-ding(1.Fujian Agriculture and Forestry University,Fuzhou 350002;2.Fuzhou University,Fuzhou 350002);Faulty Line Detection of Resonance-grounding Cable System[J];Journal of Chongqing University of Science and Technology(Natural Sciences Edition);2008-06
5 YU Wen-hui1,LI Jian2,CHEN Zu-xun2(1.Maomen Power Supper Bureau,Maomen 525000,China; 2.The Extrahigh Voltage Subcompany of Shandong Electric Power Company,Jinan 250021,China);A novel voltage arc-suppression method for grounding faults in distribution networks[J];Journal of Electric Power Science and Technology;2012-01
6 ZHOU Yong-zhong,WEI Shu-qiong,LU Guang-hui,LIANG Jing-wan (1.Chongqing Electric Design Institution,Chongqing 400030,China. 2.Xu Ji Electric Co.,LTD,Xuchang 461000,Henan,China);Embodiment of Automatic Arc-suppression Coil and Grounding Fault Line Selection for Incorporate Device in Smart Substation[J];Electrical Measurement & Instrumentation;2011-09
7 HUANG Zhi-chao,ZHONG Yi,LI Cai-lin,LI Zhen,YAN Hong-yan(School of Mechanical and Electrical Engineering,Guilin University of Electronic Technology, Guilin 541004,Guangxi,China);A Method of Single Phase-to-ground Faulty Line Selection Based on Harmonic Wavelet[J];Electrical Measurement & Instrumentation;2012-01
8 PANG Qing-le(School of Information & Elec.Eng.,Shandong Institute of Business & Technology,Yantai 264005,China);Study of fault line detection based on rough set neural network for distribution network[J];Advanced Technology of Electrical Engineering and Energy;2009-04
9 Zhang Qingchao Yao Bin Yang Jinfei Wang Zhenhua (Tianjin University Tianjin 300072 China);Fault Line Identification and Fault Location of Non-Direct Ground Neutral System Based on R/S Dimension[J];Transactions of China Electrotechnical Society;2007-12
10 Shu Hongchun1 Peng Shixin2 Li Bin1 Zhao Xingbing3 (1. Kunming University of Science and Technology Kunming 650051 China 2. Kunming Power Supply Bureau Kunming 650011 China 3. Yunnan Electric Power Designing Institute Kunming 650051 China);Simulation After Detecting Fault Line in Resonant Earthed System Through Zero Sequence Current Motivation[J];Transactions of China Electrotechnical Society;2008-10
China Proceedings of conference Full-text Database 10 Hits
1 LI Bo1,CHU Lili1,LIU Yanjun2 1 Information Science&Engineering College,Liaoning University of Technology,Jinzhou 121001,P.R.China2 School of Sciences,Liaoning University of Technology,Jinzhou 121001,P.R.China;On Small Current Grounding System in Single-phase Grounding Fault Line Selection Based on DSP[A];[C];2010
2 ;保护装置中小电流接地选线功能的探讨[A];[C];2010
3 PANG Qing-le, CAO Yin-jie, MU Jian, LANG Feng-fa (School of Control Science and Engineering, Shandong University, Jinan 250061, China; School of Computer Science, Liaocheng University, Liaocheng 252059, China; School of Physics Science and Information Engineering, Liaocheng University, Liaocheng 252059, China);Study on Fault Line Detection Based on Rough Set Theory in Indirectly Grounding Power System[A];[C];2006
4 Jin Zhiqiang,Zhang Yanxia,Fang Ting,Shi Yong (School of Electrical Engineering and Automation,Tianjin University,Tianjin 300072,China);New Line-selection Methods for Single Phase Grounding Fault in Distribution Networks with Two Phase's Current Transformers[A];[C];2007
5 Xu Zhiqiang, Liu Mingguang (School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044);a New Method to Recognize Fault with Railway Signal Power Source[A];[C];2005
6 LUO Jian WANG Guan-jie Chongqing University,Chongqing 400044,China HE Jian-jun Chongqing Electric Power Co.,Chongqing 400014,China;The research on fault line selection in network grounded with arc extinguishing coil[A];[C];2008
7 Xiong ZhiWei,Cai JinDing (1.Fujian Agriculture and Forestry University,Fuzhou,350002; 2.Fuzhou University,Fuzhou,350002);Faulty line detection of 6kv~35kv resonance-grounding cable system[A];[C];2008
8 (DANG Xiao-qiang~1,LEI Xia~(2,3),LIU Jun-yong~2,CHEN Yun-liang~1,ZHANG Li~(2,3),TANG Guo-dong~2,PENG Xiao-dong~1) (1.College of Water Resource and Hydroelectric Engineering,Sichuan University,Chengdu 610065,China,2.College of Electrical Engineering and Information,Sichuan University,Chengdu 610065,China,.3.College of Electrical Engineering and Information,Xihua University,Chengdu 610039,China);Study of traveling waves in main electrical equipments-technique implement[A];[C];2008
9 JIA Lei DU Hong-ji DAI Guang-wu (School of Power,Nanjing University of Science & Technology,Nanjing 210094,China);Simulation of Single-phase Earth Fault in Resonant Earthed System Based on Matlab[A];[C];2008
10 JIE Linling TANG Kunming State Key Laboratory of Power Transmission Equipments & System Security and New Technology,Chongqing University,Chongqing 400044,China; ZHANG Taioin ZHOU Xiaoping Chongqing New Century Electrical Co.,Ltd.,Cbongqing 400030,China;Development of small current grounding line selection device based on transient characteristic signal integrated criterion[A];[C];2008
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 LI Juan~1,JIAO Shao-hua~2 (1.Department of Computer science & Automation, Beijing Institute of Machinery, Beijing 100085,China;2.Beijing Si fang Automation Co Ltd,Beijing 100085,China);A new principle of single-phase-earth fault detection based on distribution automation platform[J];Journal of Beijing Institute of Machinery;2005-02
2 He Lizhi (Heilongjiang University,Harbin 150001,China);The research of the fast-measuring methods for main frequency parameters[J];Electrical Measurement & Instrumentation;2001-04
3 Zhu Dameng,Sun Hongjun(Acheng Relay Co., Ltd. ,Heilongjiang Acheng 150302,China);The application of BP networks to ground fault line detection in peterson-coil-grounding system[J];Electrical Measurement & Instrumentation;2004-06
4 Zhou Hao (Zhejiang University);Research the Detection of Grounded Lines in 10kV Distribution System by Parallel Resistor[J];Electrotechnical Journal;2003-11
5 Zhang Hongyan~1,Zhang Chengxue~1,Xiong Rui~2,Wang Qi~1(1.Wuhan University,Wuhan City, 430072;2.South-middle China Electric Power Design Institute,Wuhan City,430071);Analysis and Comparison of Several Advanced Fault Line Selective Methods in Small Current Grounding Power System[J];Electric Power Construction;2005-11
6 Xue Yongduan~1 Xu Bingyin~2 Li Tianyou~3 Li Jing~2 Chen Yu~2 Feng Zuren~1 (1.Xi' an Jiaotong University,Xi'an,Shanxi Province,710049; 2.Kehui Electrical Limited,Zibo,Shandong Province,255031; 3.Quanzhou electric Power Bureau,Quanzhou,Fujian Province,362000);Single Phase Fault Detection Techniques Based on Transient Signals in Non-solid Grounded Networks[J];Electrical Equipment;2001-03
7 XU Bing-ying, XUE Yong - duan, LI Tian - you, XIAN Ri - chang (Shandong University of Technology,Zibo 255049,China;Quanzhou Power Company, Quanzhou 362000,China;Zibo Power Company,Zibo 255032 ,China);Review of Line Selection of Grounding Fault in Non - Effectively Grounding Network Techniques[J];Electrical Equipment;2005-04
8 LU Guo-qing1,ZHANG Rui-hong2,LIU Wei-guo2,YANG Xu2,SHI Dong-xia2(1. Electric Power Research Institute,Guangdong Power Grid Co.,Guangzhou 510600,China;2. Guangzhou Zhiguang Electrical Inc.,Guangzhou 510640,China);Comparison and Analysis on Line Selection Node of Small Disturbance Method and Shunt Resistance Method[J];Electrical Equipment;2007-08
9 Wang Zuguang (Nanjing Automation Research Institute);FEEDER EARTH FAULT SELECTING DEVICE FOR NEUTRAL ISOLATED AND PETERSEN COIL GROUNDED SYSTEMS[J];Automation of Electric Power Systems;1993-06
10 Zeng Xiangjun. Yin Xianggen. Chen Deshu. Zhang Zhe. Zeng Xiaoyuan(l. Huazhong University of Science and Technology. Wuhan 430074, China)(2. Guangzhou Ken General Electric Co Ltd. Guangzhou 510245, China);FEEDER GROUNDING FAULT PROTECTION TO IMPLEMENT DISTRIBUTION AUTOMATION[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-15
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved