Design and Laboratory Study of A Conductivity Water Holdup Meter

GUO Hai-min, ZHENG Jian-feng, DAI Jia-cai (Key Lab of Exploration Technologies for Oil & Gas , Ministry of Education (Yangtze University), Jingzhou 434023)  
In consideration of the problems in a conductivity water holdup meter for monitoring oil-gas wells under the conditions of high water cut, in connection with the sensor structures of measuring the wellbore water holdup with conductive method, the meter is developed or is being tested in the laboratory both at the home and abroad, the design project, its measuring principle and basic parameters of a sonde conductive sensor are proposed, of which the influence factors and the results of lab experiments are analyzed primarily.
【Fund】: 中国石油天然气集团公司科技攻关项目 (2 0 0 2B0 2 0 4)
【CateGory Index】: P631.83