Application of Temperature Sensor to Microwave Heat-therapy System

LIANG Shouyu (Automatic Control Department, South China University of Technology, Guangzhou 510640,China)  
As a result of high frequency electromagnetic wave serious interference, measure temperature in microwave field all along being an difficult problem belongs to the measure and automatic domain. Here advances an temperature sensor structure which make use of Thermistor-High Resistance Conductors to resolve this problem fairly good,and the article puts emphasis on method how to realize this structure. This temperature sensor has been applied to produce microwave heat-therapy medical instruments for hospital, its characteristics of resist strong electromagnetic wave interference is satisfactory.
【CateGory Index】: TP212.11
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 2 Hits
1 Wu Shizeng Yu Yang (Institute of Electrical Engineering,Chinese Academy of Science,Beijing,100080,China);The Temperature Detecting Techniques Resisting Electromagnetic Interference and Its Application in the Microwave Hyperthermia System[J];Modern Scientific Instruments;2008-01
2 FENG Jian-shu 1 ,FANG Ying 1 ,GUO Qing 2 ,WANG Jin-xi 1 ,ZHAO Chuan-hua 1 ,YUE Yun 1 (1.Taishan Medical College,Taian Shandong271000,China;2.Taian Central Hospital,Taian Shandong271000,China);A study on the testing system of the performance of medical temperature sensor[J];Information of Medical Equipment;2004-05
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 LIU Guo yong 1,CHEN Jie ping 2 (1.Dept. of Mech.& Eleco.,Bengbu High-Acdemic Institute,Bengbu,Anhui,233030,China 2.Dept. of Eng.& Tech..,Anhui Tech.. Teachers College, Fengyang, Anhui, 233100,China);Design of Using Singlechip Control Stepmotor System[J];Journal of Anhui Technical Teachers College;2002-04
2 LENG Hui?wen,WANG Dong?xing(School of Mechanical Engineering and Automation,Anshan Institute of I.& S.Technology,Anshan 114002,China);An Intelligent Control Module for Three-Phase Induction Motors[J];JOURNAL OF ANSHAN INSTITUTE OF IRON AND STEEL TECHNOLOGY;2000-02
3 WANG Jing-sheng~1,ZHENG Ye~2(1.School of Electric Engineering and Automation,Hefei University of Technology,Hefei 230009,China;2.Hefei Sanyang Electric Co.Ltd,Hefei 230088,China);Computer testing system of refrigerator's refrigeration performance based on modbus[J];Journal of Anhui Technical College of Water Resources and Hydroelectric Power;2005-04
4 MA Ming LI Zhen - yu (Anyang University);The Method of Increasing Reliability of RS-485 Interface[J];Journal of Anyang University;2003-01
5 LIU Jiang1, SUN Yi-cai1, WANG Zhi-xin1, LI Hong-zhong2 (1.Hebei University of Technology, Tianjin, 300130 China; 2. Tianjin Huali Automobile Co. Ltd, Tianjin, 300401 China);Hardware-software design of counter-type dynamometer printing and recording system[J];Semiconductor Technology;2001-12
6 YU Hai-tao(College of Automation Engineering, Nanjing University of Aeronauticsand Astronautics,Nanjing 210016,China);Design of intelligent solid-state microwave-sweeperbased on MAX038[J];Semiconductor Technology;2003-03
7 MA Xiang-guo, GU Wen-qi (Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing 100080, China; Graduate School, Chinese Academy of Sciences, Beijing 100039, China);Fabrication Process and Technology for Emit Needle of LMIS[J];Micronanoelectronic Technology;2005-03
8 ZHANG Baobin,YUAN Shihua,ZHAO Ran(School of Mechanical and Vehicular Engineering, Beijing Institute of Technology, Beijing 100081, China);A Study on the Control System of Hydro-Mechanical Variable Transmission[J];Acta Armamentarll The Volume of Tank, Armored Vehicle and Engine;2003-04
9 QI Zhisheng1,LOU Xiaoping2,LI Qiguang1,MIAO Xiaochun3(1.Department of Mechanical Engineering, Beijing Institute of Machinery,Beijing 100085,China; 2.Department of Electronic Information Engineering, Beijing Institute of Machinery,Beijing 100085,China; 3.Beijing Wistar Technology & Trade Co., Beijing 100083,China);The design of NC R-core coil winding machine control system[J];Journal of Beijing Institute of Machinery;2003-02
10 GU Yu-hai,WANG Xiao-chuan,XU Xiao-li (Department of Mechanical Engineering, Beijing Institute of Machinery, Beijing 100085,China);A system design of embedded color measurement instrument[J];Journal of Beijing Institute of Machinery;2003-04
China Proceedings of conference Full-text Database 6 Hits
1 YANG Ting-hua (Tianjin Industry University, institution of higher profession,Tianjing 300134);A Monitor System of Papermaking Net Manufacture Taking Advantage of Chip Microprocessors[A];[C];2005
2 Wang Guotian (Manager Department of Laboratary and Equipment,Yangzhou University,Jiangsu 225009,China);An Instrument Design of PCR Based on the Principle of Thermoelectric Refrigerati on and Fuzzy-PID Algorithm[A];[C];2007
3 Li Yunpeng (Chengdu University of information technology,Chengdu 610225,China);Design of precise process calibrator[A];[C];2007
4 Zhou Hongbin 1 Qian Junlei 2 (1 The Zhongran City Gas Company of Jiaozuo, HeNan province 2 Hebei Polytechnic University, Tangshan, HeBei province);A Motor's Soft-starter System Based on Intel 87C196KC Micro-processor[A];[C];2008
5 Ling Guoping Zhou Xinjian (First Engineers Scientific Research Institute, General Armaments Department, Wuxi 214035, China);How to Improve RS485 Communication Reliability in Measure and Control System[A];[C];2005
6 Shao Xuan (School of Automation Science and Electrical Engineering BeiHang University Beijing 100038);The design and the testing for the circuit controlling frequency in multifunctional CD Player[A];[C];2009
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 MA Ju-liang,NI Hui-qiong,ZHANG Xiao-bing(Anhui University of Science and Technology,Huainan 232001,China);Study Progress of Luminescence of Rare Earth Polymer Complex[J];Anhui Chemical Industry;2007-01
2 QIAO-E; AN Zuo-Ping; LUO Cheng-mu; WANG Ting-yun (Shenyang Shenbian Instrument Transformer Manufacture Co., Ltd., Shenyang 110025, China; Electric Engineering Department of Tsinghua University, Beijing 100084, China);Development and Application of Optical Current Transformer: Looking Forward for Instrument Transformer Technology in 21st Century[J];TRANSFORMER;2000-01
3 YAN Yan 1,CHANG Tao 1,LUO Cheng mu 1, QIAO E 2(1.Tsinghua University, Beijing 100084, China; 2.Shenyang Shenbian Instrument Transformer Manufacture Co.,Ltd., Shenyang 110135, China);Circuit of Hybrid Optical Current Transformer[J];Transformer;2001-11
4 WANG Shao-kui (Power Supply Company,Daqing Petroleum Management Bureau,Daqing163453,China);Development Difficult Points and Present Situation of Electronic Current Transformer[J];Transformer;2003-05
5 LI Xin 1\ ZHANG Ligeo 1\ WANG Yanling 2 1.Electrical Engineering Department of Yanshan University,Qinhuangdao, 066004, P.R.China 2.Beixing Steel Stock Company;Bio-Medical Temperature Measurement System Based on Fiber Fluorescence and Wavelet Analysis[J];Journal of Transcluction Technology;2003-01
6 Zhang Youjun; Hu Wenhao;Tang Weizhong (Basis Department, Zhengzhou Grain College, (Department of Telecommunication,Zhengzhou 450052) Zhejiang University);Development of the Experiment System of the Optical Fibre Temperature Sensor[J];JOURNAL OF TRANSDUCER TECHNOLOGY;1997-02
7 GUAN Xiao-ping [(Dept. of Maths and Phys., Yanshan University, Qinhuangdao 066004, China);A novel fluorescence temperature measurement system with optical fiber[J];Journal of Transducer Technology;2001-04
8 QU Bo, CHEN Xiao-lin, WANG Zhu-ying, JIAN Zhi-jian, XIE Zhong, REN Chang-xue (Dept of Applied Phys,Hunan University ,Changsha 410082,China);Thermocouple device for temperature measurement used in the microwave diathermy apparatus[J];Journal of Transducer Technology;2003-12
9 Zheng Longjiang; piao Bo (The College of Electrical Engineering, Yanshan University ,Qinhuangdao 066004) Shi Xiangqian (Personnel Bureau of Qinhuangdao, Qinhuangdao 066004);A New Fluorescence Temperature Sensor with Optical Fiber[J];Journal of Yanshan University;2001-02
10 LI Peng1, CAI Zhibin2, LUO Chengmu1(1. Department of Electrical Engineering, Tsinghua University, Beijing 100084, China;2. Tonghua Power Supply Bureau, Jilin Tonghua 143000, China);Study on power supplies for hybrid optical current transformer[J];Advanced Technology of Electrical Engineering and Energy;2003-04
【Secondary References】
Chinese Journal Full-text Database 4 Hits
1 Wu Ying, Xie Jia-qi, Zhang Cai-pingICU of Xinhua Hos-pital, Dalian Univer-sity, Dalian 116021, Liaoning Province, China;Features and clinical application of intelligentized multiparameter monitor[J];Journal of Clinical Rehabilitative Tissue Engineering Research;2009-09
2 XIA Li-ming,ZHANG Yi-chuan,XIA Li-yang,YAO Ying,CHEN Tao(Jiangsu Provincial Medical Equipment Inspection Institute,Nanjing Jiangsu 210022,China);Physio-parameter Detection and Type Test of Multi-parameter Monitor[J];Information of Medical Equipment;2007-09
3 Jia Danping,Jia Ting,Yuan Weiqi,Lin Yingwen(School of Information Science and Engineering,Shenyang University of Technology,Shenyang 110178,China);Non-exponential component of fluorescence decay and its processing[J];Chinese Journal of Scientific Instrument;2008-12
4 WANG Hui,ZHENG Tianlei,PEI Xiaoxu,ZHAO Minglong,TANG Heyun*(Faculty of Medical Imageology,Xuzhou Medical College,Xuzhou 221004,China);Real-time Temperature Monitoring Device in Infants[J];Clinical Medicine & Engineering;2010-03
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved