A Method to Measure the Additive Constant of the Photoelectric Distance Meter without Using the Baseline

Qiu Licun et al.  
In order to guarantee the accuracy of surveying instruments, the additive constants of them should be examined periodically during they are used. In the paper, a simple and effective method to measure the additive constant of the photoelectric distance meter is described, in which the standard surveying baseline need not be used and the additive constant of the photoelectric distance meter could be measured accurately through making the three-stage measurement for four times on a flat ground. The method eliminates the effect of periodic error and pointing error and is proved to be simple in measurement operation and suitable for field inspection.
【CateGory Index】: P204
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 1 Hits
1 YANG Weifang1,2,3,FU Huiqing3(1.School of Civil Engineering,Lanzhou Jiaotong University,Lanzhou 730070,China;2.Institute of Geophysics,China Earthquake Administration,Beijing 100081,China;3.Institute of Seismology,China Earthquake Administration,Wuhan 430071,China);Progress in electro-optical distance meters′ calibration methods[J];Optical Instruments;2008-04
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 ZHANG Zhi-wei (College of Traffic and Transportation Engineering,Southeast University, Nanjing 210096, China);The effect of short base line on examining multiplication constant correction coefficient of total station and the countermeasure in engineering[J];Engineering of Surveying and Mapping;2005-01
2 NING Jin-sheng,YANG Kai(School of Geodesy and Geomatics,Wuhan University,Wuhan 430079,China;Chinese Society of Geodesy,Photogrammetry and Cartography,Beijing 100037,China);The newest progress of surveying & mapping discipline from digital style to informatization stage[J];Science of Surveying and Mapping;2007-02
3 ZHAO Ji-xian,NIE Yun-ju;Development of Survey Instrument:Review and Prospect[J];Bulletin of Surveying and Mapping;2008-02
4 WU Yuan hua 1, ZHANG Xue zhuang 2 (1.Department of Surveying and Geo informatics, Tongji University, Shanghai 200092,China; 2.Department of Geodetic Science and Geomatics, Central South University, Changsha 410083, China);The Calibration and Measurement of Aerial Baseline[J];Acta Geodaetica Et Cartographic Sinica;2002-S1
5 LI Song LIU Bo (School of Electronic Information ,Wuhan Wniversity, 129 Luoyu Road, Wuhan 430079, China);THE CALCULATION OF THE ACTIVE REFLECTING AREA OF THE CUBE CORNER PRISM[J];Wtusm Bulletin of Science and Technology;2002-04
6 ZHU Shunping XUE Ying (Zhengzhou Institute of Surveying and Mapping, 66 Middle Longhai Road, Zhengzhou 450052, China);PRECISE VERIFICATION OF EDMI'S PERIODICAL ERRORS[J];Wtusm Bulletin of Science and Technology;2002-04
7 ZHANG Wei 1 ZHANG Kaiyuan (1 Supervising and Examining Station of Surveying and Mapping Product's Quality, 12 Hanlin Road, Shenyang 110015, China);AN APPROACH TO THE SOLUTION OF THE EMD'S CONSTANT OF ADDITION AND MULTIPLICATION[J];Wtusm Bulletin of Science and Technology;2002-06
8 YE Xiaoming~1 LING Mo~2 CHEN Zenghui~3(1 School of Geodesy and Geomatics,Wuhan University,129 Luoyu Road,Wuhan 430079,China;2 Instiute of Earthguake China Earthguake Administration,40 Hongshance Road,Wuhan 430071,China;3 Guangdong institut of verification for surveying instruments,468 East Huanshi Road,Guangzhou 510075,China);TEST OF ADDEND AND MULTIPICATOR OF ELECTRONIC DISTANCE METER[J];Wtusm Bulletin of Science and Technology;2005-06
9 Yang Boxiong1,2),Hu Xinhe3),Lu Jie1,2),Chen Zhigao1,2),Liu Haibo1,2),Ou Tonggen1,2) and Fu Huiqing1,2) 1)Institute of Seismology, CEA, Wuhan 430071 2)Crustal Movement Laboratory, Wuhan 430071 3)Profession Technological College of Xianning of Hubei Province,Xianning 437100;VERIFICATION AND CALIBRATION OF SEISMIC OBSERVATION INSTRUMENT[J];Journal of Geodesy and Geodynamics;2006-01
10 Yang Weifang1,2,3),Yang Boxiong3)and Fu Huiqng3)1)Institute of Geophysics,CEA,Beijing 1000812)School of Civil Engineering,Lanzhou Jiaotong University,Lanzhou 7300703)Institute of Seismology,CEA,Wuhan 430071;ON WEIGHTED ADDITIVE CONSTANT AND MULTIPLICATION CONSTANT IN VERIFICATION OF ELECTRO-OPTICAL DISTANCE MEASUREMENT[J];Journal of Geodesy and Geodynamics;2007-02
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved