Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Journal of Clinical Radiololgy》 2005-03
Add to Favorite Get Latest Update

Feasibility of Multislice CT Angiography with Low Dose Contrast Media in the Head and Neck

LI Mingli, JIN Zhengyu, ZHANG Yunqing,et al.Department of Radiology, Peking Union Medical College Hospital, Chinese Acadamy ofMedical Sciences & Peking Union Medical College, Beijing 100730, P. R. China  
Objective To study the feasibility of multislice CT angiography with low dose contrast media in the head and neck.Materials and Methods Thirty patients with head/neck 16 slice CT angiography were divided into 3 groups according to the dosage of contrast media as follows: 100 ml, 80 ml, and 60 ml. Each group was graded by using source image and MIP reconstruction for vascular delineation of carotid and intracranial arteries and veins, and the artifacts. Intravascular CT attenuation values were recorded and assessed. Results The carotid and intracranial arteries, vertebral ateries in all groups were well delineated and there were also no significant difference statistically among the three groups on subjective graded scores. There was no significant difference in the scores in delineations of veins and artifacts among three groups. CT attenuation values in the aortic arch, common carotid artery, internal carotid artery, anterior cerebral artery and middle cerebral artery were high, and with no significant difference among three groups.Conclusion It is feasible to use low dose contrast media with 16 slice CT angiography in head and neck.
【CateGory Index】: R816.2
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 10 Hits
1 ZHOU Wan-jun,YIN Hao-zhi,LIU Yong-gang,et al.Department of Radiology,Changle People′s Hospital,Shandong 262400,P.R.China;Comprehensive Application of Angiography Data in Head and Neck[J];Radiologic Practice;2007-08
2 DING Tong-wenl.Department of Radiology,The People's Hospital of Puyang, Henan,457000,China;Application of brain CT Perfusion and scan from head side to foot side in 16 multislice CT angiography in the head and neck[J];Chinese Journal of CT and MRI;2009-06
3 WU Zong-xia, LEI Zhen, QIAN Ying, WANG Zhi-ming(Department of Radiology, the First Affiliated Hospital of Liaoning Medical College, Jinzhou Liaoning 121001, China);The feasibility study of MSCT angiography with low dose contrast media in the carotid artery:a canine experimental model[J];Journal of China Clinic Medical Imaging;2009-04
4 ;CT Angiography in Application of Atherosclerosis of Carotid Artery[J];Journal of Practical Radiology;2008-12
5 YANG Min(The Fifth People's Hospital of Dalian,Dalian,Dalian,Liaoning 116021,China);Study on the Application Technique of Multi-slice Spiral CT Perfusion in of Thyroid Diseases[J];Journal of Practical Medical Techniques;2008-21
6 LIU Yong-gang,LIANG Fu-kui,YIN Hao-zhi,LIU Ming-biao,LIU Fa-qiang (Changle People's Hospital,Changle,Shandong 262400,China);The clinical and imaging analysis of the Youth spontaneous cerebral hemorrhage[J];Journal of Practical Medical Techniques;2008-22
7 YANG Min(The Fifth People’s Hospital of Dalian,Dalian,Liaoning 116021,China);Study on the Technique of Multi-slice Spiral CT Perfusion in the Application of Kidney Tumor[J];Journal of Practical Medical Techniques;2008-33
8 SU Yi-juan,MO Yong-xiang.X-ray Department,Wangjiangshan Hospital,People′ Hospital of Zhejiang Province,Hangzhou 310014,China;Diagnosis of Carotid Artery Stenosis by Multilayer Spire CT[J];Chinese General Practice;2009-15
9 LU Feng-qi,YU Xiang-rong,WANG Dong,YU Xun,ZHANG Lei,HUA Dong-ying(Wuxi Second People's Hospital,Jiangsu 214002,China);Carotid arteries angiography with 64-slice spiral CT in low dosage of the contrast media[J];Shanghai Medical Imaging;2010-03
10 Zhai Feng-xin,Niu Yu-jun,Wang Zhi-ming,Lei Zhen Department of Radiology,First Affiliated Hospital of Liaoning Medical University,Jinzhou 121001,Liaoning Province,China;Three-dimensional imaging of multi-slice spiral CT angiography with low concentration and low dose iodine contrast agent in canine carotid artery[J];Journal of Clinical Rehabilitative Tissue Engineering Research;2010-52
【Citations】
Chinese Journal Full-text Database 1 Hits
1 LIU Xiang, DAI Jian-ping, ZHAN Jiong, SUN Bo. Department of Neuroradiology, Beijing Neurosurgical Institute, Beijing 100050, China;The application study of CT perfusion and CT subtraction angiography in the stenosis and obstruction of internal carotid artery[J];Chinese Journal of Radiology;2003-08
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 YAO Gang,SUN Jian-nan,LIU Ying,ZHANG Xiu-li,CHEN Xiu-mei(CT Division,Daqing Oil Field General Hospital,Daqing 163001,China);Feasibility of 16-slice helical CT Angiography with low dose Contrast Agent in the Lower Extremity[J];Computerized Tomography Theory and Applications;2005-04
2 LIU Ying,ZHANG Xiu-li,LIU Dong-hong,YAO Gang,YANG Yue-e(Daqing Oil field General Hospital,Daqing 163001,China);Application of 16-slice Spiral CT in the Diagnosis of Carotid Cavernous Fistula[J];Computerized Tomography Theory and Applications;2006-01
3 LIU Ying,ZHENG Xiu-li,YAO Gang (CT Division,Daqing Oil Field General Hospital,Daqing 163001,China);Application of 16-slice Spiral CT Angiography(CTA) with Tracking Technology of Contrast Medium in lower extremity[J];Computerized Tomography Theory and Applications;2006-03
4 YAO Gang,SUN Jian-nan,LIU Wei-li,LI Xue-yan,CHEN Xiu-mei(CT Division,Daqing Oil Field General Hospital,Daqing 163001,China);Application of 16-slice Spiral CT Angiography in Diagnosis of Upper Extremity Arterial Disease[J];Computerized Tomography Theory and Applications;2006-04
5 ZHANG Xiu-li,YAO Gang,LIU Ying(CT Division,Daqing Oil Field General Hospital,Daqing 163001,China);Application of 64-slice Spiral CT in the Diagnosis of Moyamoya Disease[J];Computerized Tomography Theory and Applications;2007-03
6 LIU Li, WU Jing-quan, LI Xin-you, OUYANG Yu, LU Fa-jin, WEN Ming, LI Qi (Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing 400016, China);Value of 64-slice CT angiography in diagnosis of arteriosclerotic occlusive disease of lower extremities[J];Acta Academiae Medicinae Militaris Tertiae;2008-22
7 JIANG Shan, XIAO Ge-lin, CHEN Shuang (Department of Radiology, Nanhai District Songgang Hospital of Foshan City, 528234, Guangdong, China);Diagnostic value of CTA with 16-slice in arteriosclerotic occlusive disease of lower limb[J];Hainan Medical Journal;2008-07
8 Yang Xuehua,Tan Yanzhao,Gao Jianbo,et al.Department of Radiology,the First Affiliated Hospital of Zhengzhou Medical University,Zhengzhou 450052,China;The evaluation of 64 multi-slice spiral CT angiography in the diagnosis of cerebral and carotid artery diseases[J];Chinese Journal of Practical Nervous Diseases;2008-09
9 KUANG Ye,ZHANG Zhong-lin.(Department of Radiology,the Second Affiliated Hospital of Nanhua University,Hengyang,Hunan 421001,China);Diagnosis of Cavernous Transformation of Portal Vein With Multi-slice CT[J];Journal of Nanhua University(Medical Edition);2006-04
10 SUN Jian-nan, YAO Gang, LIU Ying, GAO Li-yuan, CHEN Xiu-mei, ZHOU Fa-jin, BI Chun-long (Department of CT, Daqing Oilfield Head Hospital, Daqing 163001, China);Application of 64-slice spiral CT chest three-in-one scan in examination of acute chest pains[J];Chinese Journal of Interventional Imaging and Therapy;2008-01
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 JIANG Jin-dai, LI Yang-bin, TAN li-lian, LI Shu-xin, LIANG Tong-jie, ZHOU Shao- ping. No. 2 Hospital Affiliated to Guangzhou Medical College, Guangdong 510260, China;Diagnosis of carotid artery diseases using MSCTA[J];Chinese Journal of CT and MRI;2006-02
2 LUO Jian-jun, LI Xiao-bing, XU Jian-ming, LIU Ren-jian, KUAI Jian-ping, ZHANG Wen-qi.Department of Radiology, Suzhou Municipal Hospital, Jiangsu 215002, China;Role of three-dimensional contrast-en- hanced MR angiography in diagnosing arterial diseases in head and neck[J];Chinese Journal of CT and MRI;2006-02
3 ZHU Xin-jin,ZHAO Ji-quan,ZENG Hui-liang,et al.Department of Imaging Center, the Second People’s Hospital,Foshan,Guangdong 528000,China;The application of 16-row CT angiography in the diagnosis of carotid body tumor[J];Chinese Journal of CT and MRI;2008-03
4 LI Wei1,SHU Rong-wen2,MAO Jun1,WANG Yan-ping1,LIU Yu-tao1,LIN Li-juan1(1.People's Hospital of Zhuhai,Zhuhai 519000,Guangdong,China;2.Nanjing General Hospital of Nanjing Military Command,PLA,Nanjing 210002,Jiangsu,China);Discuss on the technique of 16-slice spiral CT coronary angiography in the diagnosis of coronary artery stenosis[J];Journal of Southeast China National Defence Medical Science;2007-05
5 LU Ren gen,WANG Jian hua.Department of CT,Ningbo No.2 Hospital,Zhejiang 315010,P.R.China;Evaluation of the relationship between the space-occupying lesions and the carotid atery with CT Angiography[J];Radiologic Practice;2003-12
6 XIAO Ping,TAN Li-lian,LI Yangbin,et al.Department of CT,the Second Affiliated Hospital of Guangzhou Medical College,Guangzhou 510260,P.R.China;Clinical Application of the Bolus-triggered Technique with 16-slice Spiral CT in CT Angiography of Cervical Arteries[J];Radiologic Practice;2006-05
7 SUN Cong,LIU Cheng,WANG Dao-ping,et al.Department of CT,Imaging Research Institute of Shandong Medical University,Jinan 250021,P.R.China;An Application Study on the Feasibility of Multi-slice CT Abdominal Angiography with Low Dose and High Concentration of Contrast Media[J];Radiologic Practice;2007-03
8 ZHU Jing-qi,CHANG Shi-xin,HAO Nan-xin,et al.Department of Radiology,East Hospital,Tongji University,Shanghai 200120,P.R.China;Assessing the Stability of Carotid Artery Atherosclerotic Plaques by CTA and CE-MRA[J];Radiologic Practice;2007-08
9 FU Chuan-ming, CHEN Wen, CHEN Jie, CHEN Lun-gang, ZOU Jian-hua, XU Jian (Department of Radiology, the Affiliated Taihe Hospital, Yunyang Medical Colledge, Shiyan 442000, China);Image Quality Factors of 64-Slice Spiral CT Aorta Angiography:Comparison with 16-Slice Spiral CT[J];Computerized Tomography Theory and Applications;2010-02
10 LIANG Wen, TANG Hai-liang ,XIEYurru,et al. Department of Radiology,The Zhujiang Hospital, Nan fang Medical University,Guangzhou Guangdong 510282, China;Preliminary study of Hepatic Perfusion Imaging with 64-slice Spiral CT[J];Military Medical Journal of South China;2007-03
【Secondary References】
Chinese Journal Full-text Database 1 Hits
1 FAN Zi-ping1,QIAO Zhi1,WU De-jing2.1.Department of General Surgery,Baoshan Department of Shanghai First People's Hospital Affiliated to Shanghai Jiaotong University,Shanghai 200940,China;2.Department of General Surgery,Changzheng Hospital,The Second Military Medical University,Shanghai 200003,China;Analysis on Diagnosis and Relapse Factors of Thyroid Gland Cancer[J];Chinese Journal of Bases and Clinics in General Surgery;2010-01
【Secondary Citations】
Chinese Journal Full-text Database 2 Hits
1 LU Xiaoyan, ZHANG Wanshi, XU Jiaxing, et al. Department of CT and MRI, Air Force General Hospital of PLA, Beijing 100036,China;The application of MR and CT angiography in the evaluation of carotid artery stenosis and follow up of carotid endarterectomy[J];Chinese Journal of Radiology;2001-05
2 LIU Xiang, DAI Jianping, SUN Bo, et al Department of Neuroradiology, Beijing Neurosurgical Institute, Beijing 100050;The preliminary research of CT perfusion imaging in intraaxial ischemic disease[J];CHINESE JOURNAL OF RADIOLOGY;1999-07
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved