Application of Two-way Valve in Air Conditioning Water System

ZHANG Xiao-yun, AN Da-wei, LOU Cheng-zhi(School of Environment Science & Technology, Tianjin University, Tianjin 300072, China)  
Integrating the principle with characteristic of regulating valve, several problems of three-way valve used in air conditioning water system are analyzed. The resolution method using two-way valve is put forward.
【CateGory Index】: TU831
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 1 Hits
1 WANGCheng1,HAOYan-feng2(1.InstituteofArchitecturalDesign,NanjingUniversity210096,China;2.DailianInstituteofArchitecturalDesign,Dalian116022,China);Application of Dynamic Flow Balance Valves in HVAC[J];Construction Machinery For Hydraulic Engineering & Power Station;2003-02
【Co-citations】
Chinese Journal Full-text Database 5 Hits
1 Xiang Xiaochun,He Jing and Zhang Jing;Design of Air Conditioning System for Shanghai Shenshui Port Service Business Building(Phase 1)[J];China Construction Heating & Refrigeration;2007-05
2 By Dai Wenxian ★★Fujian Province Architecture Design and Research Institute, Fuzhou, China;Air conditioning design of markets with booths for rent[J];Hv & Ac;2004-05
3 By Guo Jianxiang ★, Zhou Yangmin, Yi Chuijie and Fang Junxi★Qingdao Polytechnical University, Qingdao, Shandong Province, China;Design of variable section of self-acting flow control valves[J];Hv & Ac;2005-01
4 JIN Xiu-hui~1,ZHANG Jun-liang~1,ZHOU Yang-min~2,FU Ying-ying~1(1.Department of Mechanical & Electronic Engineering,Dezhou University,Dezhou 253015,China;2.Qingdao University of Technology,Qingdao 266033,China);Application of Automatic Flow Control Valves in Household Heating System[J];Mechanical Engineering & Automation;2007-01
5 SHEN Xin-rong,ZHANG Wei-jun,LI Yan,ZHU Wen-bin;The Numerical Analysis and Experimental Study for Linear Character of a Control Valve[J];Chinese Hydraulics & Pneumatics;2007-10
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 ;Properties and Application of Thick Film Platinum Resistor Temperature Sensor[J];Sensor World;1997-11
2 LIU Gang1,2,JIAO Yang2,JIA Shu-hong2(1.Jilin University,Changchun 130022,China;2.Air-force Aviation University,Changchun 130022,China);Application of Parameter Self-adaptive Fussy PID Control in Central-conditioner Saving-energy System[J];Power Electronics;2007-11
3 ZHANG Wen HU Sheng-Qing School of Instrument, Hefei University of Technology, Hefei, 230009, China;Compensation Technology for Thermal Errors of Piezoresistive Sensor[J];Electronics Quality;2003-11
4 LI Yu\|yun;Discussion of the water systematic energy saving technology of central air conditioner[J];Energy Conservation;2003-02
5 Sun Lijun;Zhang Tao;Li Gang School of Electric Work & Automation Engineering,Tianjin University, Tianjin 300072;EXPERIMENTAL STUDY ON THE PERFORMANCE CHARACTERISTIC OF THE TURBINE FLOW SENSOR[J];Chinese Journal of Mechanical Engineering;2004-05
6 CHEN Yuan-xiang(Hongyuan Building Engineering Co. Ltd., Datong Coal Industry Group, Datong 037006, China);Discussion on cold and heat source issues of central air conditioning[J];Shanxi Architecture;2004-06
7 By ZENG Yong★ Shen Zhen Shenfubao Property Development Co.,LTD, China;The Use of Transducer in the Water System of Air-conditioning[J];Contamination Control & Air-conditioning Technology;2004-02
8 XU Yu-dang, WANG Nian, LEI Fei (Huazhong University of Science & Technolog, Wuhan Hubei 430074, China);The Analyses and Improvements of Variable Flow Water System in Central Air-conditioning[J];Energy Technology;2003-06
9 WANG Huai1, YANG Lixin2, ZHAO Xingang1(1. North China Municipal Engineering Design & Research Institute, Tianjin 300074, China; 2. Xingtai Gas & Heat General Company, Xingtai 054000, China);Configuration and Choice of Circulation Pump of Heat-supply Network[J];Gas & Heat;2003-04
10 CHEN Li-ping~1,WANG Lu-wei~2,WEI Ling~1(1.College of Urban Construction and Safety & Environmental Engineering ,Nanjing University of Technology,Nanjing 210009,China; 2.Department of Electranic Information,Chengdu University, Chengdu 610106, China);Assessment on energy consumption of heat/cold source of air conditioning and environmental influence[J];Journal of Nanjing University;2004-03
【Secondary References】
Chinese Journal Full-text Database 1 Hits
1 ZHAO Shan-feng,DING Yun-fei,ZHOU Xiao-qing(The Center of Building Saving of Guangzhou University,Guangzhou 510006,China);Study on Air-conditioning System Control Mode Based on Thermal Comfort[J];Refrigeration Air Conditioning & Electric Power Machinery;2008-02
【Secondary Citations】
Chinese Journal Full-text Database 2 Hits
1 By Huang Wei Zhang Bai, Xu Wei and Zou Yu;Difference of balance valves and auto flow valves in hydraulic system balance application[J];HV & AC;1999-05
2 By Tian QiTaiyuan University of Technology, China;Selection of the balance valve in heating systems[J];Hv & Ac;2001-01
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved