TEST AND RESRARCH OF FLUE GAS TEMPERATURE DEVIATION AT THE FURNACE EXIT OF A 2008t/h BOILER WITH TANGENTIAL FIRING

Zhou Junhu et al  
Directing against the existence of big flue gas temperature deviation (up to 130℃) at the furnace exit of 2000t/h boiler in a power plant, cold state test and numerical simulation under four different opposing tangential angles for the air dynamic behaviour in the furnace, the reaidual gas flow swirl at the furnace exit, and the gas flow velocity distribution in the horizontal flue gas duct have been carried out, and the influencing factors upon the flue gas temperature deviation, such as fictitious diameter of the tangential circle, height of the furnace, as well as structure and swing angle of the burner etc., being analysed. The results show, a reasonable opposing tengential angle can effectively suppress and weaken the gas velocity and gas temperature deviation at the exit of furnace. And it is very helpful to decrease the said deviation by swinging upward the burner for a certain angle.
【CateGory Index】: TK227.1
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 4 Hits
1 LIU Xin-zhi1,LI He1,ZHU Shu-guang1,JING Xiao-lei21.College of Power,Nanjing University of Science & Engineering,Nanjing 210094,Jiangsu Province,PRC2.Xi'an Thermal Power Research Institute Co Ltd,Xi'an 710032,Shaanxi Province,PRC;TEST STUDY ON CONTROLLING HEAT DEVIATION IN UTILITY BOILERS BY USING JET-FLOW READJUSTING METHOD[J];Thermal Power Generation;2008-09
2 JIANG Xiu-min1,CUI Zhi-gang1,MA Yu-feng2,WANG Hui2,ZHANG Chao-qun1(1.School of Mechanical Engineering,Shanghai Jiaotong University,Minhang District,Shanghai 200240,China;2.School of Energy Science and Engineering,Harbin Institute of Technology,Harbin 150001,Heilongjiang Province,China);NUMERICAL SIMULATION AND ENGINEERING PRACTICE OF A 670t/h CORNER TANGENTIAL BOILER WITH REVERSE-TANGENT AND SWIRLING-ELIMINATION[J];Proceedings of the Csee;2005-18
3 ;Retrofit of the Burner of420t/h Tangential Corner-firing Boiler[J];Zhejiang Electric Power;2005-01
4 ZHAO Hong-yu,LUO Zhi-Hao,CHEN Bo(Zhejiang Electrical Test and Research Institute,Hangzhou Zhejiang 310014,China);Analysis and Improvement for Steam Temperature Deviation of 600 MW Supercritical Once-through Boiler[J];Zhejiang Electric Power;2010-03
【Citations】
Chinese Journal Full-text Database 1 Hits
1 Wu Fengting(Qingshan Thermal Power Station) Lu Xuenong Zeng Hancai Nie Mingju(Huazhong University of Science and Technology);Experimental Research on Gas Side Temperature Imbalance in Horizontal Pass of Large Boiler[J];JOURNAL OF COMBUSTION SCIENCE AND TECHNOLOGY;1998-03
【Co-citations】
Chinese Journal Full-text Database 3 Hits
1 LIU Tong, XU Gang;CALCULATION OF WALL-TEMPERATURE FOR SUPERHEATER AND REHEATER OF HG670/13.7-YM13 TYPE BOILER[J];Thermal Power Generation;2004-10
2 ZHENG Xiaokang, ZHANG Chuanming, SONG Guoliang et al;CAUSE ANALYSIS AND TEST STUDY ON SOMEHAT LOWER STEAM TEMPERATURE FOR A 2008t/h CORNER TANGENTIAL FIRING BOILER[J];Thermal Power Generation;2004-11
3 CHEN Qian,ZENG Xue-mei,CHU Yun-tao 1.Mid-South China Electric Power Design Institute,Wuhan 430071,HubeiProvince,PRC 2.Mid-China University of Science and Technology,Wuhan 430072,Hubei Province,PRC;NUMERIC VALUE STUDY ON THE INFLUENCE OF FLUE GAS TEMPERATURE DEVIATION ALONG THE DIRECTION OF HEIGHT UPON THE WALL TEMPERATURE OF REAR PLATEN SUPERHEATER[J];Thermal Power Generation;2007-09
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 Wu Jinghui(9);ANALYSIS OF THE DESIGN CHARACTERISTICS OF TYPE E-420-13.7-560KT BOILER BURNER MADE IN RUSSIA[J];THERMAL POWER GENERATION;2000-03
2 MA Yu-feng et al;RETROFIT AND OPERATION OF CORNER TANGENTIAL BURNERS WITH REVERSE-TANGENT AND SWIRLING-ELIMINATION FOR A 670t/h BOILER[J];Thermal Power Generation;2001-05
3 CHEN Da-wei et al;STUDY ON PRESSURE BEHAVIOR IN HORIZONTAL FLUE GAS DUCT OF TANGENTIALLY FIRED BOILER AFTER BIASING SH PANELS[J];Thermal Power Generation;2003-12
4 Zhang Xuan, Xu Tongmo, et a1. (Xi'an Jiaotong University);A Preliminary Study on the Reduction and Eli-mination of F1ue Gas Parameters Deviation at Both Sides of a Boi1er Gas Duct through the Introductionof Antj--ta;1gcntial Air[J];Journal of Engineering for Thermal Energy and Power;1996-05
5 Li Yanpeng, Xu Jinyuan (Xi'an Jiaotong University) //Journal of Engineering for Thermal Energy & Power.-1999, 14(6).-428~430;Numerical Simulation of the Effect of Arch Nose Structure on Furnace Upper Section Flow Field[J];JOURNAL OF ENGINEERING FOR THERMAL ENERGY AND POWER;1999-06
6 Zhou Qulan, Dou Wenyu, Zhou Yuegui, et al (Xi'an Jiaotong University) //Journal of Engineering for Thermal Energy & Power.-2000, 15(2).-116~118;The Effect of an Reverse Tangential Air Distribution on the Flow Field Characteristics in a Large sized Boiler Furnace[J];JOURNAL OF ENGINEERING FOR THERMAL ENERGY AND POWER;2000-02
7 Zhao Yuan, Dong Pe ng, Qin Yuk un, et al (College of Energy Science and Engineering under the Harbin Instit ute of Technology);The Effect of a Secondary Air Injection Angle on the Deviation of Flue Gas Flow Rate at a Tangentially Fired Furnace Outlet[J];JOURNAL OF ENGINEERING FOR THERMAL ENERGY AND POWER;2000-03
8 LIU Tai sheng, XU Jin yuan (Institute of Energy and Power Engineering under the Xi'an Jiaotong University, Xi'an, China, Post Code: 710049), SHEN Lin, YAO Ben rong (Dongfang Boiler Group Co. Ltd., Zigong, Sichuan Province, China, Post Code: 643001);Theoretical and Experimental Study of the Impact of In-boiler Swirl Number on the Thermal Deviation in a Reheater[J];Journal of Engineering for Thermal Energy and Power;2003-04
9 /Zhou Yuegui, Dou Wenyu, et al (Xi'an Jiaotong University);The Effect of a Front platen Superheater on Gas Velocity Deviation in the Flue gas Duct of a Tangentially Fired Boiler[J];JOURNAL OF ENGINEERING FOR THERMAL ENERGY AND POWER;1999-03
10 ZHU Zhen jin, ZHANG Chang lu, LI Liang, FANG Zhi cheng, ZHUANG Jian (Dept.of Power Engineering,Shanghai University of Electric Power,Shanghai 200090,China);Experimental Studies of Airflow Velocity Deviation Characteristics at Flue Gas Duct Effected by Residual Rotation at Outlet[J];Journal of Combustion Science and Technology;2001-03
【Secondary References】
Chinese Journal Full-text Database 3 Hits
1 SUN Ke,ZHANG Jun-wei,WU Gui-fu(Power Research Center of China Huadian Corporation,Hangzhou 310030,China);Experimental Study on Cold Aerodynamic Field of 1913t/h Supercritical Tangential Firing Boiler[J];Refrigeration Air Conditioning & Electric Power Machinery;2009-06
2 GOU Xiang, ZHOU Jun-hu, ZHOU Zhi-jun, YANG Wei-juan, LIU Jian-zhong, CEN Ke-fa (State Key Laboratory of Clean Energy Utilization (Zhejiang University), Hangzhou 310027, Zhejiang Province, China);Tertiary-air Effects on Combustion and NO_x mission in Tangentially Fired Furnace[J];Proceedings of the CSEE;2008-08
3 GOU Xiang, ZHOU Jun-hu, ZHOU Zhi-jun, YANG Wei-juan, LIU Jian-zhong, CEN Ke-fa (State Key Laboratory of Clean Energy Utilization (Zhejiang University), Hangzhou 310027, Zhejiang Province, China);Selection of Position of Pulverized Coal Reburning Injector in Low NO_x Retrofit Schemes[J];Proceedings of the CSEE;2008-20
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved