ANALYSIS OF OPERATIONAL PERFORMANCE FOR ADMIX-BURNING COAL WITH LOW ASH FUSING POINT IN BOILER OF 300MW UNIT AT ZHANGJIAKOU POWER PLANT

FAN Quan-gui, XIAO Li-jia, LI Yu-kun  
Directing against operational performance of admixburning coal with low ash fusing point from Wei County, Hebei Province, in boiler of 300 MW unit at Zhangjiakou Power Plant, test and calculation analysis have been carried out, the influence of coal quality variation upon slagging behavior, combustion behavior, steam temperature behavier, and boiler efficiency being emphasized, and reasonable coalblending scheme being put forward. Practical operation shows that the conclusion of analysis in this paper is in conformity with realities.