Variable Air Volume Design for Smoke Exhaustion and Ventilation Systems of Underground Parking Garage

WANG Zi-yun,LIU qin-li (Institute of Architecure & Engineering of Henan University of Science and Technology,Luoyang 471003 Henan China)  
The paper analyses the characteristic of the air volume calculation of the ventilation and smoke exhaustion systems of underground parking garage,points out that the fixed air volume design goes against energy conservation of the systems and the systems should be designed as variable air volume systems at the same time the paper introduces the usage of the frequency conversion technology in the ventilation and smoke exhaustion systems of underground parking garage.
【CateGory Index】: TU834
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 4 Hits
1 By Sun Yanxun;Comments on smoke exhaustion and ventilation of the underground parking in high rise buildings[J];HV & AC;2000-01
2 By Lin Qichang ★ and Wu ShijingFuzhou Architectural Designing Institute, China;New code for garage fire protection and smoke management design of the underground garage in highrise buildings[J];Hv & Ac;2001-06
3 By Cheng Tongbao;Combined application of mechanical ventilation and smoke extraction for underground carparks in highrise buildings[J];HV & AC;1998-02
4 LIAO Jian wei (The Architectural Design & Research Institute of Guangdong Province,Guangzhou,Guangdong 510010);Variable Air Volume Design for Underground Parking Garage Exhaustion Systems[J];Refrigeration;2002-02
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 YANG Qiang~1,SHAN Min~2(1.Academy Of Hangzhou Environment Science,Hangzhou 310014,China;2.Department Of Plant Protection,Zhejiang University,Hangzhou 310029,China);Talking About Pollution Source Strength Calculation of Vehicle Emission In Underground Garages[J];Environmental Science and Management;2006-05
2 Xu Shuhui Xing Yunfei (Dept. of Urban Construction Engineering, Beijing 100044);Mechanical Ventilation and Smoke Exhaust System for Underground Garage in High-Rise[J];Journal of Beijing Institute of Civil Engineering and Architecture;2003-04
3 YAN Xu-ming, et al. (Dalian Hong da International Corporation,Dalian 116001,China);Discussion on the way to solve the problem of ventilation and exhaust smoke in underground garage using the system of inducing fan[J];Journal of Changchun Institute of Technology;2004-02
4 WANG Wei-dong LI Wen-feng(Pingdingshan planning Bureau ,467000,Henan,Pingdingshan,China);Design of ventilation to discharge somke in underground garage[J];Journal of Pingdingshan Institute of Technology;2004-03
5 CHEN Jun-ping, ZHAO Lei (School of Municipal &Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China);Calculation of the Exhaust Volume of the Underground Garage and Simulation on Pollutant Dispersion Process[J];Construction Energy Conservation;2009-06
6 SUN Liang LI Jie(Beijing institute of architectural design and research,Beijing 100045,China);Ventilation System Design for Basement Garage of High Rise Civil Building[J];Construction Quality;2010-12
7 By Ma Guangyu and Yang Ziqiang;Some Problems on Exhaust Design of Hotel Buildings[J];Building Energy & Environment;2001-05
8 Meng Changzai,Chen Xinghua,Huo Tianqiang and Ma Guangxing;Analysis and Study on the Formulas of Ventilation Rate Calculation in the Underground Car Parks[J];Building Energy & Environment;2003-01
9 Yang Chunshui1 and Liao Shengquan2(1 China Textile Industrial Engineering Institute;2 Center for Engineering Design and Research under the General Equipment Department, PLA);HVAC Design of a Underground Garage[J];Building Energy & Environment;2004-01
10 HUANG Zhi gang 1 LIANG Guang 2 YANG Xiao feng 1 (1.PLA's Institute of Logistic Engineering, Chongqing 400016, China; 2. Chongqing Iron and Steel Design Research Institute, Chongqing 400016, China);Ventilation and smoke exhausting design for underground garage[J];Shanxi Architecture;2003-08
【Co-references】
Chinese Journal Full-text Database 1 Hits
1 By Ge Fenghua~★,Liu Xunjun and Liu Ye★Jilin University,Changchun,China;Energy consumption analysis of ventilation systems in underground car parks[J];Heating Ventilating & Air Conditioning;2006-03
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved