Study on the on-line life monitoring technique for the boiler high temperature heating surface tube bundles

YANG Dong,WANG Zhong-yuan (Shanghai Electric Power Test & Research Institute,Shanghai 200437,China)  
The high temperature heating surface such as the superheater and reheater of the large-size utility boiler all experience a relatively severe working condition. The failure of the boiler tubes will directly impact the safe and economic operation of the boilers. According to the analysis of the damage mechanism of the high temperature heating surface the tube damage is mainly caused by the exceeding of the limit temperature of the heating surface. The creep damage caused by the exposure of the tube metal to the unallowable high temperature for a long time proves the main metal failure mode of the tubes, directly influencing the service life of the heating surface. An on-line life monitoring model of the high temperature heating surface was set up according to the well-known L-M formula of the creep damage. The tube wall metal temperature and working stress are on-line monitored, and with this model the real time calculation of the life consumption of the heating surface tube bundles has been realized. Based on this technique the high temperature heating surface on-line life monitoring and management system was developed for the 300MW utility boiler. An effective device was thus suggested for the implementation of the safe operation and the condition based maintenance of the utility boilers.
【CateGory Index】: TM621.2
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 3 Hits
1 WEI Tei zheng, XIE Ying bo (Dept. of Power Engrg., North China Electric Power Univ., Baoding 071003, China);A Calculation Method for Life Span of Boiler High Temperature Part[J];POWER ENGINEERING;2000-01
2 Liu Lin-hua; Wang deng-hao;YangZhong--xuan(Harbin University of Technology).;A New Way to Calculate the Wall Temperature of Superheaters and Repeaters of Utility Boilers[J];POWER ENGINEERING;1995-02
3 ZENG An-feng,LUO Yong-hao,WANG Meng-hao,LU Fang,BIAN Shao-shuai;Safe Performance Online Monitoring System of Superheaterand Reheater of Utility Boiler[J];Boiler Technology;2001-12
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 XIE Shou-ming, GAO Hong-bo, ZHAO Jie, WANG Lai, HAN Shuang-qi (Dalian University of Technology, Dalian 116024, China);FES-DP System and Z Parameter Method to Evaluating Residual Life of Cr5Mo Steel[J];Journal of Materials Engineering;2004-04
2 Wang Xiuqing Zhao Jinglin Xie Hailong(Department of Thermal Power Engineering,NortheastChina Institute of Electric Power Engineering,Jilin City China 132012)Zou Tianshu(Northeast China Institute of Electric Power Scientific Research,Shenyang 1;Study of Calculation Method of SuperheaterWall Temperature of Power Plant[J];JOURNAL OF NORTHEAST CHINA INSTITUTE OF ELECTRIC POWER ENGINEERING;1998-02
3 WEI Tie-zheng, WEI Le (North China Electric Power University, Baoding 071003,China);Analysis of Low Steam Temperature of 200 MW Boilers in Douhe Power Plant and Retrofitting[J];Information On Electric Power;2002-01
4 YAN Wei ping, CHEN Hua gui, YE Xue min, LIANG Xiu jun (North China Electric Power Univ., Baoding 071003, China);Calibration Method for Calculating Tube Wall Temperature of The High Temperature Convective Heat Transfer Surface in The Utility Boilers[J];Power Engineering;2002-03
5 LIUTong~1,XUGang~1,PANG Li-ping~1,LIANG Zhi-fu~2 (1. North China Electric Power University, Beijing 102206, China; 2. Mongda Power Limited Liability Company, Inner Mongolia 014300, China);Creep Analysis and Life Calculation of the Pressure Components inside Boiler[J];Power Engineering;2004-05
6 CHEN Hong-wei,CHEN Cong,GAO Jian-qiang(School of Energy Sources and Power Engineering,North China University of Electric Power,Baoding 071003,China);An Online Wall Temperature Monitoring System for High Temperature Heat Delivery Surfaces of Boilers[J];Journal of Power Engineering;2006-01
7 CHEN Hong-wei, CHEN Cong, WANG Chun-bo;Modular Design and Application of Tube Wall Temperature Online Monitoring System of Boiler[J];Power System Engineering;2005-05
8 ZENG An-feng,LUO Yong-hao,WANG Meng-hao,LU Fang,BIAN Shao-shuai;Safe Performance Online Monitoring System of Superheaterand Reheater of Utility Boiler[J];Boiler Technology;2001-12
9 CHEN Cong,CHEN Hong-wei,GAO Jian-qiangSchool of Energy and power Engineering Noth China Eleceric Power Universiey,Baoding 071003,China;The Application of Integrated Modular Modeling Software for Tube Wall Temperature Online Monitoring System in Boiler of Power Plant[J];Boiler Technology;2006-04
10 WANG Hong-guang1, ZHAO Guo-chao1, XU Li-jun1, BI Zheng-yi2, ZHANG Wen-yu2, SHI Jun2 (1.College of Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China; 2.Waigaoqiao Power Plant, Shanghai 200137, Ch;The online system of failure diagnosis for the superheater and reheater in utility boilers[J];JOURNAL OF UNIVERSITY OF SHANGHAI FOR SCIENCE AND TECHNOLOGY;2000-03
【Secondary Citations】
Chinese Journal Full-text Database 1 Hits
1 Liu Lin-hua; Wang deng-hao;YangZhong--xuan(Harbin University of Technology).;A New Way to Calculate the Wall Temperature of Superheaters and Repeaters of Utility Boilers[J];POWER ENGINEERING;1995-02
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved