LI Zi-sheng1,2,XIAO Xiao-ping3(1.School of Manufacture Science and Engineering,Southwest University of Science and Technology,Mianyang 621010,China;2.Sichuan Key Lab of Reverse Engineering and Rapid Prototyping Manufacturing,Mianyang 621010,China;3.Center of Engineering Technology,Southwest University of Science and Technology,Mianyang 621010,China)  
Considering the difference of video standard and requirement of quality of images,a method of capturing image by dynamically setting capturing assemblies is presented.Interface program technology is applied to abstract method,inherited by software development kit of video card and the interface management assembly.Video captured by load assembly with reflection dynamically,in turn binding the corresponding video card.After the capture flow is given,the design of capture interface is discussed;the implement assembly of SDK2000 video card is demonstrated.The result show that development and republishing software are eliminated after the video cards are altered,thus the extensibility and maintainability of software is enhanced,and also the portability of software is improved.
【Fund】: 国家自然科学基金项目(10876034);; 四川省教育厅基金项目(07za176);; 西南科技大学重点基金项目(08zx1102)
【CateGory Index】: TP274.2
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 6 Hits
1 HUANG Zhi-feng, LI Zheng, ZENG Jie, HUANG Qing-ping, KANG Ke-jun(Department of Engineering Physics, Tsinghua University, Beijing, 100084, China);Micro-focus radiation image acquisition and communication based on DICOM[J];Nuclear Electronics & Detection Technology;2005-05
2 WU Hong-tan, YE Han-xiao ( China Inst. of Metrology, Zhejiang Hangzhou 310034, China; Zhejiang Inst. of Traditional Chinese Medicine, Zhejiang Hangzhou 310056, China);Design and implementation of a medical video flow acquisition system[J];Computer Engineering and Design;2003-04
3 Ding Zhaoguo Xu Longyun (College of Optics and Electronics Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China);Implement of Digitizing for Medical Image in Conventional X-ray Machine[J];Chinese Journal of Scientific Instrument;2004-S3
4 YU Da-kun1, JI Chao-yang2 (1.Department of Biomedical Engineering,Xianning College,Xianning Hubei 437100,China;2.Graduate School of Electronics and Calculator,Huazhong Normal University, Wuhan Hubei 430079, China);The Application and Design of the Image Collecting Station of Color Ultrasonography Based on PACS[J];Chinese Journal of Medical Physics;2004-06
5 LIU Ju bei,ZHUANG Tian ge Shanghai Jiao Tong University (200030);PACS-Based Endoscope Image Acquisition Workstation[J];Chinese Journal of Medical Instrumentation;2001-01
6 PENG Wen-xian1,2, PENG Tian-zhou1, XIA Shun-ren2, JIN Guang-bo1 1 Rui'an Municipal People's Hospital, Zhejiang Province, 325200 2 Key Lab of Biomedical Engineering of Education Ministry, Zhejiang University, 310027;Design and Development of the DSA Digital Subtraction Workstation[J];Chinese Journal of Medical Instrumentation;2008-03
【Co-citations】
Chinese Journal Full-text Database 4 Hits
1 LUO Jian-wei1,LUO Xiang-sheng1, FANG Jian2, TAN Jun-zhao1,HU Jian-ping1,YANG Jian-guo1 (1.Computer Information Center, Zhaoqing First People's Hospital, Zhaoqing Guangdong 526021, China;2.Guangdong Julong Information Technology Limited Corporation, Dongguan Guangdong 523326, China);Research of Old-style DSA Equipment Digital Transformation[J];China Medical Devices;2009-07
2 GAI Li-ping,WANG Gui-lian(Lalian Medical University,Dalian 116027,Liaoning Province,China);Mechanism simulation of blood cell velocity measurement by Doppler ultrasonic blood equipment[J];Chinese Medical Equipment Journal;2006-09
3 LIAN Xuan,ZHU Yi-xinNo.1 Affiliated Hospit'al,Wenzhou Medical College Zhejiang University;A Practical System for B-Mode Ultrasound Image Aequisition and Pationt's Medical Histesy Management[J];Chinese Journal of Medical Instrumentation;2002-03
4 SUN Jing-yang1,LIANG Ming1,YAO Tian-ming1,YU Jian-hao2,WANG Dong-hui1,HAN Ya-ling1(1.General Hospital of Shenyang Military Area Command,Shenyang 110016,China;2.Beijing Smart Image Technology Company Limited,Beijing 100028,China);Development and Application of Vehicle-mounted Medium C-arm Angiography System[J];Chinese Medical Equipment Journal;2013-02
【Secondary Citations】
Chinese Journal Full-text Database 5 Hits
1 HU Yangqiu, GAO Xiaorong, GAO Shangkai. Dept. of Electrical Engineering and Applied Electronics, Tsinghua University, Beijing\ 100084;The Methods and Practice of DICOM Medical Image Acquisition[J];Beijing Biomedical Engineering;2001-01
2 Dai Yintao; Wu Qiyao(Beijing Institute of Technology, Beijing 100081);A Client /Server Hospital Image Processing System[J];BEIJING BIOMEDICAL ENGINEERING;1996-04
3 ZHU Qi-biao,CUI Ruo-fei(China University of Mining and Technology,Xuzhou Jiangsu 221008,China);Design of Medical Image Work Station Based on the PACS[J];Journal of Hebei Institute of Technology;2005-02
4 LIU Xiao-lei,LIU Chang-chun,ZHANG Yun-gang(School of Control Science and Engineering,Shandong University,Jinan 250061,China);The Conversion Implementation of the Standard Medical DICOM Image[J];Journal of Biomedical Engineering Research;2005-03
5 ZHUANG Tian-ge Department of Biomedical Engineering Shanghai Jiao Tong University;PACS Evolution in China between 1990-2000 and its Prospect[J];Chinese Journal of Medical Instrumentation;2002-02
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved