A method was developed for determination of deoxynivalenol in silage feed by high performance liquid chromatographic(HPLC) method.Sample of silage was extracted with water and cleaned up by an immuno-affinity column (DON-test),then analyzed by HPLC.Linear range of DON was 0.1 ~ 5.0 mg/kg with correlation coefficient of 0.9997.The average recovery at the spiked levels of 0.5,1.0 and 2.0 mg/kg for silage feed was 82 % ~ 117 %,and the relative standard deviation was 5.1 % ~ 7.8 %.The detection limit(S/N=3)was 0.05 mg/kg for deoxynivalenol.