Evaluation of the biological safety of permanent magnets embedded with a silicon membrane using intermuscular implantation test

Wang Jianhuo1, LiMeijun1, Lei Jun 1 etal.1 The 1st Surgical Department of the 476th Clinical Division of Fuzhou General Hospital of Nanjing Military Area Command, Department of pathology,Fuzhou 350002; 2 Department of Orthopaed- ics,Changzheng Hospital, Shanghai 200003, P.R. China.  
Objective To investigate the biological safety of silicon membrane embedded permanent magnets of a micturition alert device on the principle of compass. Methods The experimental group used a silicon membrane embedded NdFeB magnet which was 10 mm in diameter and 3 mm in thickness with a magnetic induction intensity of 0.3 Tesla at the center of the pole face surface. The control group used a silicon membrane embedded NdFeB alloy with the same dimensions. The grafts were implanted into the spatium intermusculare of the lateral vertebral muscle in 8 rabbits. All the rabbits were scheduled to be fed up to one year. Both the reaction of rabbits and local pathology around the grafts were observed after implantation. Results Wound healing was normal after muscular implantation of grafts in 8 rabbits, one of which died from emaciation 19 days after operation and others lived with excellent tolerance. The grades were 1 for the inflammatory reaction and fibrous capsule of the local tissue around the grafts in both experimental and control group. Conclusion NdFeB permanent magnets embedded with silicon membrane were biologically safe to meet the criteria for clinical application.
【Key Words】: Micturition alert device Magnetic field Biological safety Silica gel
【Fund】: 国家自然科学基金资助项目(30772217)
【CateGory Index】: R318.08
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 7 Hits
1 WANG Jun-Xue, LUO Er-Ping, SHEN Guang-Hao, XIE Kang-Ning, WU Xiao-MingDepartment of Military Medical Equipment & Metrology, School of Biomedical Engineering, Fourth Military Medical University, Xi'an 710033, China;Clinical effect of constant magnetic field on postoperative wound healing[J];Journal of the Fourth Military Medical University;2006-08
2 ZHU JieBiophysics Lab, College of Physics and Information Technology, Shanxi Normal University, Xi'an 710062 China;Study on the Biological effects of Magnetic Fields and Its Possible Mechanisms[J];Biomagnetism;2005-01
3 Zhang Yu, Zhang Xiao-yun School of Life Sciences, Shenzhen University, Shenzhen 518060, Guangdong Province, China;Acute toxicity effects of 4T superconductive static magnetic field in rats[J];Chinese Journal of Clinical Rehabilitation;2006-01
4 Chang Hanying , Yu Guo ,Li Hui , et al. General Hospital of PIL, Beijing 100853;Effects of magnetic field on scar tissues[J];CHINESE JOURNAL OF PHYSICAL THERAPY;1997-01
5 WANG Minghua*,KONG Xiangming, ZHANG Xiaoyun,et al.*Department of Orthopaedics, Hangzhou 4th People's Hospital, Hangzhou 310002, China;Effects of high magnetic field on wound healing and scar adhesion in mice[J];Chinese Journal of Physical Medicine and Retabulitation;2000-06
6 WANG Jianhuo, HOU Chunlin, ZHANG Wei, ZHENG Xianyou, XU Zhen, WANG Wanhong, LIN Haodong. Department of Orthopedic Surgery, Changzheng Hospital, the Second Military Medical University, Shanghai, 200003, P.R.China.;MICTURITION ALERT DEVICE DEDICATED TO NEUROGENIC BLADDERS[J];Chinese Journal of Reparative and Reconstructive Surgery;2008-05
7 WANG Jianhuo,HOU Chunlin,WANG Wanhong,ZHENG Xianyou,XU Zhen.Department of Orthopedic Surgery,Changzheng Hospital,the Second Military Medical University,Shanghai,200003,P.R.China;BIOCOMPATIBILITY OF MICTURITION ALERT DEVICE DEDICATED TO NEUROGENIC BLADDER[J];Chinese Journal of Reparative and Reconstructive Surgery;2008-09
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 LU Jia-xuan et al (College of Electrical Engineering,Guizhou University,Guiyang,Guizhou 550003);Magnetic Effect of Microbes and Its Application in Environment[J];Journal of Anhui Agricultural Sciences;2007-13
2 XU Zhong-chuan et al(Department of Biological Science and Food Engineering,Changshu Institute of Technology,Changshu,Jiangsu 215500);Study on the Biological Effect of Magnetic Field on Growth of Lindera aggregata (Sims) kosterm Plantlet in vitro[J];Journal of Anhui Agricultural Sciences;2008-23
3 XU Zhong-chuan et al(Department of Biology and Food Engineering;Changshu Institute of Technology,Changshu,Jiangsu 215500);Study on the Biological Effects of Magnetic Treatment on the Growth of Edible Fungi Mycelia[J];Journal of Anhui Agricultural Sciences;2009-07
4 LIU Xiaoli WEI Lan FEI Xiaolu SUN Xuemei PENG Mingchen Xuanwu Hospital,Capital Medical University,Beijing 100053;The management and information tracing of medical materials embedded in body[J];Beijing Biomedical Engineering;2007-02
5 REN Ling1,2, NAN Li1, YANG Ke1(1 Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016;2 Graduate School, Chinese Academy of Sciences, Beijing 100049);Research and Development of Anti-infective Medical Materials[J];Materials Review;2010-11
6 XU Zhong-chuan,JI Hong,YUAN Wen-qin (School of Biology and Food Engineering,Changshu Institute of Technology,Changshu 215500,China);Biological Effects of Magnetic Field on the Growth of Flammulina velutipes(Cart.)Sing Mycelia[J];Journal of Changshu Institute of Technology;2010-02
7 ZHU Jie1, ZHANG Yin-jing2 1. College of Physics and Information Technology, Shaanxi Normal University, Xi’an 710062, China; 2. Department of Mechanical and Electrical Engineering, Henan Textile College, Zhengzhou 450007, China;Biological Effects of Different Kinds of Magnetic Fields on Tumors[J];Journal of Magnetic Materials and Devices;2005-04
8 WANG Jian-huo1,LI Mei-jun2,LEI Jun2,HOU Chun-lin3 1.The First Surgical Department,The 476th Clinical Division,Fuzhou General Hospital,PLA Nanjing Military Area Command,Fuzhou 350002,Fujian,China2.Department of Pathology,The 476th Clinical Division,Fuzhou General Hospital,PLA Nanjing Military Area Command,Fuzhou 350002,Fujian,China3.Department of Orthopaedics,Changzheng Hospital,Second Military Medical University,Shanghai 200003,China;Evaluation of biological safety of silicon membrane embedded permanent magnets implanted in canine[J];Academic Journal of Second Military Medical University;2010-03
9 LUO Er-Ping 1, SHEN Guang Hao 1, ZHOU Long Fu 1, WU Xiao Ming 1, LU Li Hua 2, LIU Da Wei 3, LI Qiang 3, XU Qiao Ling 4 1Department of Military Medical Equipment & Metrology, School of Biomedical Engineering, 2Department of Chemistry, School of Basic Medicine, 4Nursing School, Fourth Military Medical University, Xi’an 710033, China, 3Shaanxi Zhongbang Pharmaceutical Science and Technology Co., Ltd, Xi’an 710001, China;Effect of 0.2 T constant magnetic fields on wound healing in rabbits[J];Journal of The Fourth Military Medical University;2004-13
10 Lv Yi,LI Jian-Hui,LIU Chang,SHI Yuan,ZHANG Zhi-Yong,WANG Bo,YU Liang Department of Hepatobiliary Surgery,First Affiliated Hospital,Medical School,Xi'an Jiaotong University,Xi'an 710061,China;Development of sutureless magnetic bilioenteric anastomosis stents and its primary application in repairing acute bile duct injury in dogs[J];Journal of the Fourth Military Medical University;2007-17
China Proceedings of conference Full-text Database 1 Hits
1 Hongwei Lei Insititute of Electronic Science and Technology Northeastern University Shenyang,China Dan Yang Insititute of Electronic Science and Technology Northeastern University Shenyang,China Yanan Tian Insititute of Electronic Science and Technology Northeastern University Shenyang,China Xu Wang Insititute of Electronic Science and Technology Northeastern University Shenyang,China;Effect of Strong Magnetic Field Stimulator for Cardiomuscle of Rabbit[A];[C];2010
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 WANG Junhong1,2,MA Yanwei1(1 Applied Superconductivity Laboratory,Institute of Electrical Engineering,Chinese Academy of Sciences,Beijing 100080; 2 Graduate University of Chinese Academy of Sciences,Beijing 100080);Research Progress in Magnetic Polymer Matrix Nanocomposites[J];Materials Review;2007-07
2 YANG Feng yu 1, LI Yi ning 2, LIU Xin rong 3, CONG Li 4 1. Gansu University of Technology, Lanzhou 730050, China; 2. Gansu Province Women's and Children's Health Care Hospital, Lanzhou 730060, China; 3. Gansu Province Cancer Research Institut;Experiment and Analysis on Restraining Solid Tumorin Mouse by Magnetic Field[J];Journal of Magnetic Materials and Deuices;2001-04
3 YAN Deng-jun1,Li Wei1,WANG Gui-qin2,ZHAO Ji-wan2(1.Electrical Engineering Department,Hohai University,Nanjing 210098,China;2.Physics Department,Nanjing University,Nanjing 210008,China);Progress in Bio-Electromagnetism Research[J];Journal of Electrical & Electronic Education;2007-03
4 WANG Jun-Xue, LUO Er-Ping, SHEN Guang-Hao, XIE Kang-Ning, WU Xiao-MingDepartment of Military Medical Equipment & Metrology, School of Biomedical Engineering, Fourth Military Medical University, Xi'an 710033, China;Clinical effect of constant magnetic field on postoperative wound healing[J];Journal of the Fourth Military Medical University;2006-08
5 ZHAO Rui,ZHOU Hui-ying,CHU Qiu,et al(Department of Biochemistry,School of Basic Medical Sciences,Beihua University,Jilin 132001,China);The influence of magnetic field on ATP、cAMP and cGMP of big rats with AMI[J];Chinese Journal of Control of Endemic Diseases;2006-03
6 Ma Haizhen;Wu Guoqing(Taiyuan University of Technology,030024);THE STUDY OF EFFECT OF MAGNETIC FIELD ON DEHYDROGENASE OF IMMOBILIZED CELL OF PURPLE NONSULFUR PHOTOSYTHETIC BACTERIA[J];ACTA SCIENTIAE CIRCUMSTANTIAE;1995-03
7 GUO Run-xia.Institute for Environmental Health and Related Products Safety,Chinese Centers for Disease Control and Prevention,Beijing100021,China;Biological Effects of Constant Magnetic Field and Its Safety Exposure Limits[J];Journal of Environment and Health;2003-01
8 Ke Wenqi, Le Xiuhong, Wang Xueyou, Shi Jian, Guo Fengtao, Li Zhenjie, He Nanzhang, Yang Jun and Wang Laixing Naval Medical Research Institute, Shanghai 200433;The Effects of 28-Day Intermittent Exposure to High Strength (50mT) Alternating Magnetic Field[J];JOURNAL OF NAVY MEDICINE;1999-01
9 WANG Chunyao 1) ,SONG Guoying 2) ,DU Xiantang 3) ,XUE Jingli 1) , DU Chunyan 1) ,XING Jinshan 1) ,ZHU Qingfan 1) 1)Laboratory Animal Center of Henan Province, Zhengzhou 450052 2)Department of Cell Biology and Medical Genetics, Basic Medical College,Zhengzhou University, Zhengzhou 450052 3)Department of Microbiology and Immunology, Basic Medical College, Zhengzhou University, Zhengzhou 450052;Analysis on the G-banding pattern of the chromosomes and idiogram in inbred strain Yuyi hairless mice[J];Journal of Henan Medical University;2003-02
10 ZHANG Xiao yun, XUE Yan, SU Xiang e, et al (Deptartment of Bioengineering, Shenzhen University, Shenzhen, 518060, China);Effects of the magnetic field on bone mineral density, strength and metabolism in ovariectomized rats[J];Basic Medical Sciences and Clinics;2002-06
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved