Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Journal of Isotopes》 2006-03
Add to Favorite Get Latest Update

Application of ~(125)I in Micropipettor Check

QIAN Xiao-yu,GAO Yun-chao,YANG Ya-dong,LU Han-kui(Department of Nuclear Medicine,the Sixth People's Hospital of Shanghai Jiaotong University,Shanghai 200233,China)  
Gravimetric test is one of authoritative methods for the measurement and validation of the accuracy and precision of micropipettors.The feasibility of radioactive measurement in the check of micropipettors is studied.There are no significant difference in radioactive count rates of ~(125)I aspirated between 2 qualified micropipettors,but significant difference are recorded between qualified and unqualified micropipettors.So ~(125)I radiometry agrees with gravimetric tests,and can be used as a laboratory constant test of micropipettors.
【CateGory Index】: TH789
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Co-citations】
Chinese Journal Full-text Database 6 Hits
1 WANG Zhi-gang,SHAO Ping-yang (Department of Clinical Laboratory,The Second Hospital of Jiaxing,Zhejiang Provence 314000,China);Evaluation of pipettes performance by europium-labeled technique verified deviation[J];Zhejiang Journal of Laboratory Medicine;2011-01
2 Shen Wei1, Zhang Zhengjun1, Sun Jie1, Shao Pingyang2, Wang Zhigang2 (1. Jiaxing Metrological Verification & Testing Institute; 2. Second Hospital of Jiaxing, Zhejian Provence);Evaluation of pipettot perforance verified deviation by europium-labeled[J];Shanghai Measurement and Testing;2010-03
3 WANG Chao-hong,HU Liang-yong,FU Yi-bin,HE Shu-xian (Guangzhou Institute of Measurement and Testing Technology,Guangzhou 510030,China);Study on digital variable-volume pipette calibration[J];China Measurement & Test;2011-03
4 HU Liang-yong,WANG Chao-hong Guangzhou Institute of Measuring and Testing Technology,Guangzhou Guangdong 510030,China;The Study of the Testing and Calibration Method of Digital Pipette[J];China Medical Devices;2011-03
5 XU Xiao-jing,ZHAO Li-xiang(School of Basic Medicine and Biological Sciences,Soochow University,Suzhou 215123,China);Maintenance and servicing of Transferpette[J];Laboratory Science;2011-01
6 Wang Zhi-gang,Shao Ping-yang,Cao Hao-qiang(Department of Clinical Laboratory,Second Hospital of Jiaxing,Jiaxing 314000,China);Checking and calibration of pipette volume with radioisotopic iodine-125 labeling[J];Chinese Journal of Health Laboratory Technology;2008-09
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved