Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《China Medical Devices》 2008-09
Add to Favorite Get Latest Update

Methods for Verifying and Adjusting the Mechanical Isocenter of Varian Accelerators

YANG Shao-zhou,WANG Sheng-jun(Medical Equipment Department of Nanfang Hospital,Guangzhou Guangdong 510515,China)  
Describes the daily verification of the mechanical Isocenter of accelerators and the adjusting procedures if the parameter is beyond its limit.
【CateGory Index】: TL505
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 2 Hits
1 PENG Shun-yin (Equipment Department,Huai'an No.1 Hospital Affiliated to Nanjing Medical University,Huai'an Jiangsu 223300,China);Discussion about Manual Adjustment Methods of MLC in Siemens Primus Oncor Linear Accelerator[J];中国医疗设备;2010-01
2 CHEN Jian-gong (Medical Room,Fujian Institute of Measurement Science and Technology,Fuzhou Fujian 350003,China);Detection,Ajustment and Improvement Study of Coincidence Degree between Radiation Field and Optical Field[J];中国医疗设备;2009-10
【Citations】
Chinese Journal Full-text Database 2 Hits
1 FANG Ai-ling,WANG Zheng (Cancer Insititute and Hospital affiliated to Tianjin Medical University Tianjin 300060,China);Development of Iso-center Shoots and Laser Calibration Tools in Radiotherapy system[J];医疗设备信息;2007-11
2 SUN Dong,LIU Gui-mei,HU Zhong-hua(Beijing Thoracic Tumour and Tuberculosis Hospital, Beijing 101149, China );Detection and adjust ment of the orientation system for radiotherapy[J];医疗设备信息;2006-09
【Co-citations】
Chinese Journal Full-text Database 6 Hits
1 XU Feng,SI Jun,WANG Jun-hai,ZHANG Ke(Taian Tumor Hospital,Taian Shandong 271000,China);Development of the Digital Mechanical Isocenter Measuring Instrument[J];中国医疗设备;2010-03
2 PENG Yi,ZHANG Hong-yang(Medical Engineering Department,First Affiliated Hospital of Medical College of Shihezi University,Shihezi Xinjiang 832008,China);Installation and Calibration of the Laser Localizer in Radiation Therapy[J];中国医疗设备;2010-03
3 PENG Shun-you, LIANG Yi (Radiotherapy Center of Xiangfan Central Hospital, Xiangfan Hubei 441021,China );Study on Correction of Linear Accelerator Gantry Angle with Plumb Instrument[J];中国医疗设备;2009-03
4 YANG Shao-zhou,WANG Sheng-jun(Medical Equipment Department of Nanfang Hospital,Guangzhou Guangdong 510515,China);Methods for Verifying and Adjusting the Mechanical Isocenter of Varian Accelerators[J];中国医疗设备;2008-09
5 CHEN Bao-min (Shanxi Provincial People’s Hospital,Taiyuan Shanxi 030012 ,China);Design of a New Type of Radiotherapy Bed[J];中国医疗设备;2008-07
6 FANG Ai-ling,WANG Zheng (Cancer Insititute and Hospital affiliated to Tianjin Medical University Tianjin 300060,China);Development of Iso-center Shoots and Laser Calibration Tools in Radiotherapy system[J];医疗设备信息;2007-11
【Co-references】
Chinese Journal Full-text Database 5 Hits
1 YANG Shao-zhou,WANG Sheng-jun(Medical Equipment Department of Nanfang Hospital,Guangzhou Guangdong 510515,China);Methods for Verifying and Adjusting the Mechanical Isocenter of Varian Accelerators[J];中国医疗设备;2008-09
2 CHEN Jun,DU Bing-jian(Guangxi Zhuang Auronomous Regioral People's Hospital,Nanning Guangxi 530021,China);Working Principle and Troubleshooting of Multi-leaf Collimator for Siemens Linear Accelerator[J];中国医疗设备;2008-01
3 HU Jie TAO Jian-min SUN Guang-rong Department of Radiotherapy,Shanghai Tenth People's Hospital,Shanghai,200072;Quality Control and Quality Assurance for the Isocentre of the Medical Linear Accelerator[J];中国医疗器械杂志;2007-03
4 ZHANG Chun-guang,SHEN Mei-lian,ZENG Da-fu,PAN Guo-xiong(Cancer Center,Sun Yat-sen University,State Key Laboratory of Oncology in South China,Guangzhou Guangdong 510060,China);The Relationship between Field Symmetry and Injecting Current Fluctuation of Linear Accelerator[J];中国医学物理学杂志;2007-02
5 GAO Feng (The First affiliated Hospital to Chongqing Medical University, Chongqing 400016,China);Examining the performance and quality assurance of linear accelerator[J];现代医药卫生;2006-06
【Secondary References】
Chinese Journal Full-text Database 5 Hits
1 CHEN Li-jun;GU Xiao-hua;YANG Liu-qin;Department of Radiotherapy,Xinxiang Central Hospital;;Quality Control Inspection of Radiotherapy Equipment Based on Image Guided Radiation Therapy System[J];中国医疗设备;2017-01
2 GU Xiao-hua;YANG Liu-qin;Xinxiang Central Hospital;;Design and Application of QA Verification Plates and Beam Field Cross-link Plates for Radiotherapy[J];中国医疗设备;2016-02
3 GU Xiao-hua;YANG Liu-qin;Department of Radiation Oncology, Xinxiang Central Hospital;;Application of IP plate in the quality assurance inspection of radiotherapy[J];中国医学装备;2015-02
4 LIU Wen,MEI Shi-bing,XU Tao Medical Engineering Department,The Military General Hospital of Beijing PLA,Beijng 100700,China;The Design and Application of the Coherence Metrical Ruler of X-Ray Confine[J];中国医疗设备;2011-10
5 ZHU Hai-sheng,DONG Yong-ying,YAN Hao-lin Oncology Department,The First People Hospital of Yulin,Yulin Guangxi 537000,China.;Failure Analysis of Multi-leaf Collimator for Siemens Linear Accelerator[J];中国医疗设备;2011-07
【Secondary Citations】
Chinese Journal Full-text Database 7 Hits
1 SUN Dong,LIU Gui-mei,HU Zhong-hua(Beijing Thoracic Tumour and Tuberculosis Hospital, Beijing 101149, China );Detection and adjust ment of the orientation system for radiotherapy[J];医疗设备信息;2006-09
2 JIANG Xiu-ying,LI Jin,CHEN Hai,ZHAO Xin-ping (Department of Oncology of Guangzhou General Hospital of PLA,Guangzhou Guangdong510010,China);Analysis of conventional quality control detecting results of simulation[J];医疗设备信息;2005-07
3 XU Hong,CHEN Liang (Department of Radiation Oncology of Dalian Third People's Hospital,Dalian Liaoning116033,China);Quality assurance of stereotactic radiotherapy in head and neck cancer[J];医疗设备信息;2005-07
4 YANG Shao-zhou (Equipment Department of Nanfang Hospital,Guangzhou Guangdong 510515,China);A method of the verification and adjustment of X-knife system's isocenter[J];医疗设备信息;2004-08
5 YU Jin-ming,YU Yong-hua;Quality Assurance and Quality Control in Radiotherapy[J];中国肿瘤;2004-08
6 YE Shao-rong,LIN Xing-jian,WU Li-hui;Accurate fixing the laser positioner for radiotherapy[J];医疗设备信息;2004-05
7 <author>ang Chun-guang, CEN He-qing, QI Zhen-yu, et al. Cancer Center of Sun Yat - sen University, Guangzhou 510060 China;<title>utine quality assurance and quality control procedure for conventional x - ray simulator[J];中国医学装备;2004-01
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved