Study on Correction of Linear Accelerator Gantry Angle with Plumb Instrument

PENG Shun-you, LIANG Yi (Radiotherapy Center of Xiangfan Central Hospital, Xiangfan Hubei 441021,China )  
Objective To study how to correct the gantry angle of linear accelerator with plumb instrument. Methods To determine the gantry angle of linear accelerator by moving the gantry to make field central axis parallel with plumb. Results Maximum error of gantry angle was 0.2 degree when the gantry was corrected with plumb instrument. Conclusion It is convenient and accurate to determine the gantry angle of linear accelerator with plumb instrument.
【CateGory Index】: TL53
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 2 Hits
1 FANG Ai-ling,WANG Zheng (Cancer Insititute and Hospital affiliated to Tianjin Medical University Tianjin 300060,China);Development of Iso-center Shoots and Laser Calibration Tools in Radiotherapy system[J];Information of Medical Equipment;2007-11
2 HU Jie TAO Jian-min SUN Guang-rong Department of Radiotherapy,Shanghai Tenth People's Hospital,Shanghai,200072;Quality Control and Quality Assurance for the Isocentre of the Medical Linear Accelerator[J];Chinese Journal of Medical Instrumentation;2007-03
【Co-citations】
Chinese Journal Full-text Database 9 Hits
1 ZHU Long xian (Jinhua Testing Centre of Quality and Technical Supervision, Jinhua 321001,China);Design of the calibrating device on specially-used verifying stage on level rule[J];Industrial Measurement;2003-06
2 SHEN Guo-hui1, ZHANG Shu-xu1, WU Shao-kun2, YE Yu-sheng1, WANG Yu-feng1 (1. Radiotherapy Center of Tumor Hospital affiliated to Guangzhou Medical College, Guangzhou Guangdong 510095, China; 2. No. 2 Hospital affiliated to Sun Yat-Sen University, Guangzhou Guangzhou 510120, China.);Development of Dose Calculation Software for Electron Beam Irradiation[J];China Medical Equipment;2008-07
3 CHEN Bao-min (Shanxi Provincial People’s Hospital,Taiyuan Shanxi 030012 ,China);Design of a New Type of Radiotherapy Bed[J];China Medical Equipment;2008-07
4 YANG Shao-zhou,WANG Sheng-jun(Medical Equipment Department of Nanfang Hospital,Guangzhou Guangdong 510515,China);Methods for Verifying and Adjusting the Mechanical Isocenter of Varian Accelerators[J];China Medical Devices;2008-09
5 PENG Shun-yin (Equipment Department,Huai'an No.1 Hospital Affiliated to Nanjing Medical University,Huai'an Jiangsu 223300,China);Discussion about Manual Adjustment Methods of MLC in Siemens Primus Oncor Linear Accelerator[J];China Medical Devices;2010-01
6 XU Feng,SI Jun,WANG Jun-hai,ZHANG Ke(Taian Tumor Hospital,Taian Shandong 271000,China);Development of the Digital Mechanical Isocenter Measuring Instrument[J];China Medical Devices;2010-03
7 YU De-quan,GAO Hong,SHAO Qiu-jiu,LIANG Yun,ZHANG Xin(Department of Radiotherapy,Tang Du Hospital,The Fourth Military Medical University,Xi'an Shannxi 710038,China);Application and Research of Two-dimensional Ion Chamber Array in Daily Quality Assurance of Accelerator[J];Chinese Journal of Medical Physics;2010-04
8 HU Jie, TAO Jian-min, SUN Guang-rong, ZHANG Ying Department of Radiotherapy, Shanghai Tenth People's Hospital, Shanghai, 200072;Quality Assurance for the Radiotherapy Simulator[J];Chinese Journal of Medical Instrumentation;2008-03
9 Hu Jie,Tao Jianmin,Sun Guangrong,Zhang Ying,Zhang Ying Department of Radiotherapy,ShangHai Tenth People’s Hospital,Shanghai,200072;The Summa of Fourteen Years Usage for a Medical Linear Accelerator[J];Chinese Journal of Medical Instrumentation;2010-01
【Secondary Citations】
Chinese Journal Full-text Database 7 Hits
1 Huang Jia-hua Shanghai Municipal Drug and Medical Device Appraisement Center;Isocenter Rotation Resolution Analysis and Technique of Radiotherapy Equipment[J];Shanghai Journal of Biomedical Engineering;2003-01
2 YANG Shao-zhou (Equipment Department of Nanfang Hospital,Guangzhou Guangdong 510515,China);A method of the verification and adjustment of X-knife system's isocenter[J];Information of Medical Equipment;2004-08
3 XU Hong,CHEN Liang (Department of Radiation Oncology of Dalian Third People's Hospital,Dalian Liaoning116033,China);Quality assurance of stereotactic radiotherapy in head and neck cancer[J];Information of Medical Equipment;2005-07
4 SUN Dong,LIU Gui-mei,HU Zhong-hua(Beijing Thoracic Tumour and Tuberculosis Hospital, Beijing 101149, China );Detection and adjust ment of the orientation system for radiotherapy[J];Information of Medical Equipment;2006-09
5 <author>ang Chun-guang, CEN He-qing, QI Zhen-yu, et al. Cancer Center of Sun Yat - sen University, Guangzhou 510060 China;<title>utine quality assurance and quality control procedure for conventional x - ray simulator[J];China Medical Equipment;2004-01
6 Dai Jianrong, Hu Yimin. Cancer Hospital ,CAMS, Beijing 100021;The Precision and Accuracy Analysis of Target Position in X Ray Stereotactic Radiotherapy[J];Chinese Journal of Radiation Oncology;1996-02
7 YU Jin-ming,YU Yong-hua;Quality Assurance and Quality Control in Radiotherapy[J];Bulletin of Chinese Cancer;2004-08
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved