Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Chinese Journal of Scientific Instrument》 2003-S1
Add to Favorite Get Latest Update

Design of Smart Sensor to Measure Real RMS Current

Yan Xiao 1 Qian Xiaolong 2 Wang Jinkuan 2 1 (Northeastern University at Qinhuangdao, Qinhuangdao 066004, China) 2 (Northeastern University, Shenyang 110004, China)  
A smart sensor to measure real RMS current is presented. The structure and working principle of smart sensor and Hall sensor are introduced. Using the system, real RMS current can be measured precisely, and communicate with external bus.
【CateGory Index】: TP212
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 8 Hits
1 CHEN Shou-qiang,XIAO Rong-chuan,XIAO Ji-xue(School of Mechanical Engineering and Automation,Xihua University,Chengdu 610039,China);Research on signal processing in power smart sensor[J];Transducer and Microsystem Technologies;2008-11
2 Liu Xianzheng1 Yang Cheng'en2 Wang Ying1(1.Sinovel Wind Group Co.,Ltd.Beijing 100081;2.Information Science and Technology College,Dalian Maritime University,Dalian 116026);Application of true RMS measurement circuit in frequency converter[J];Electronic Measurement Technology;2010-10
3 XIAO Jixue,YANG Yu,WANG Kai,LI Shixi (School of Mechanical Engineering and Automation,Xihua University,Chengdu Sichuan 610039,China);Research on Active Power Test for AC Power[J];Machine Tool & Hydraulics;2010-14
4 LI Shi-xi,XIAO Ji-xue,WANG Kai(School of Mechanical Engineering and Automation,Xihua University,Chengdu 610039,China);Research on Estimation of Key Sampling Point in AC Power Test System[J];Control and Instruments in Chemical Industry;2010-09
5 XIAO Ji-xue,YANG Yu,WANG Kai,LI Shi-xi(School of Mechanical Engineering and Automation,Xihua University,Chendu 610039 China);Definition-based Test Methods for Active Power of AC Power[J];Journal of Xihua University(Natural Science Edition);2010-02
6 WANG Kai,XIAO Ji-xue,LI Shi-xi(School of Mechanical Engineering and Automation,Xihua University,Chendu 610039 China);Estimation of Key Sample Voltage in AC Voltage Intelligent Sensor[J];Journal of Xihua University(Natural Science Edition);2010-03
7 XIAO Ji-xue,YANG Yu,WANG Kai,LI Shi-xi (School of Mechanical Engineering and Automation,Xihua University,Chengdu 610039 China);Research on Active Power Test for AC Power Based on Correlation Analysis[J];Journal of Xihua University(Natural Science Edition);2010-04
8 XIAO Ji-xue,YANG Yu,WANG Kai(School of Mechanical Engineering and Automation,Xihua University,Chengdu 610039,China);Correlation Analysis for Signal Processing in AC Voltage Smart Sensor[J];Instrument Technique and Sensor;2010-05
【Citations】
Chinese Journal Full-text Database 1 Hits
1 HE Tao 1, HU Sheng qing 1, CAI Qing 2 (1.Dept. of Precision Instr., Hefei University of Technology,Hefei 230009,China; 2.Inst. of Test Control and Intelligence Technology,Hefei University of Technology,Hefei 230009,China);Signal condition circuit of Hall sensor[J];Journal of Transducer Technology;2001-12
【Co-citations】
Chinese Journal Full-text Database 7 Hits
1 ZHENG Wei, FU Jia xu, WANG Li jie, ZHANG Li yong (Coll of Mech & power Engin,Harbin University of Science and Technology,Harbin 150080,China);Novel interface between analogue sensors and digital computers[J];Journal of Transducer Technology;2002-04
2 JIN Yong-jun,LI Hai-bao,LIU Hui(Department of Mathematics and Mechanics,Heilongjiang Institute of Science and Technology,Harbin,Heilongjiang 150027,China);Sketch of moisture sensitive polymer use with fiber Bragg grating based humidity sensor[J];College Physics;2009-07
3 Sun Jian(School of Electric and Automation Engineering,Nanjing Normal University,Nanjing 210042,China);Examples Application of Magneto-Sensitive Z-Elements[J];Journal of Nanjing Normal University(Engineering and Technology Edition);2007-02
4 ZHAO Hongmei,MI Qichao(Pingdingshan Institute of Technology,Pingdingshan,467044,China);Signal Linear Processing Circuit Design for WZP-platinum Resistance Temperature Sensor Pt1000[J];Modern Electronics Technique;2008-05
5 WANG Feng1,MI Dong1,XU Zhang-sui1,ZOU Yan2(1.Department of Electric Engineering,Mechanical Engineering College,Shijiazhuang 050003 China;2.Section of the PLA Representation in Nanjing,Nanjing 210008,China);A Magnetic Testing Scheme Based on Hall Sensor[J];Instrumentation Technology;2007-08
6 YU Bin,JIA Ya-qiong (Department of Electric and Information,Human Institute of Technology,Hengyang 421008,China);Test Method and Realization of Capacitive Humidity Sensor Based on DSP[J];Instrument Technique and Sensor;2008-04
7 Liu Haibo(Human Institute of Technology Hengyang 421002 China);Accurate measure method of capacitive humidity sensor based on harmonic analysis measure method and realization based on DSP[J];Electronic Test;2009-09
China Proceedings of conference Full-text Database 1 Hits
1 Yan Xiao Qian Xiaolong Wang Jinkuan (Northeastern University at Qinhuangdao, Qinhuangdao 066004, China) (Northeastern University, Shenyang 110004, China);Design of Smart Sensor to Measure Real RMS Current[A];[C];2003
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 Yang Xinyong (College of Automation Engineering, Nanjing University of Aeronautics & Astronautics, Nanjing 210016, China) Huang Shengguo (College of Civil Aviation, Nanjing University of Aeronautics & Astronautics, Nanjing 210016, China);Development of intelligent magnetic heading sensor and analysis of its error compensation algorithms[J];Journal of Beijing University of Aeronautics and Astronautics;2004-03
2 CHEN Shou-qiang,XIAO Rong-chuan,XIAO Ji-xue(School of Mechanical Engineering and Automation,Xihua University,Chengdu 610039,China);Research on signal processing in power smart sensor[J];Transducer and Microsystem Technologies;2008-11
3 Shen Guofeng,Wang Qi ,Wang Hua(Dept.of Automation Measurement and Control Engineering,Harbin Institute of Technology,Harbin150001,China);Synchronous sampling software-timing compensation algorithm in AC parameters measurement[J];Electrical Measurement & Instrumentation;2003-03
4 Tang Liangrui Yang Xue (North China Power Electric University Beijing 102206 China);A De-Noising Method of Power Quality Based on Triangle Module Operator[J];Transactions of China Electrotechnical Society;2007-09
5 Shi Yanling (Command Institute of Engineering Corps);The Measurement of AC Voltage TRMS[J];Electrotechnical Journal;2003-05
6 WANG Maohai,XIE Kai,XU Zhengshan,L Shaokun(North China Power Dispatching Center,Beijing 100053,China);A Practical Method for Amplitude and Power Measurement[J];Automation of Electric Power Systems;2007-16
7 ZENG Bo,TENG Zhaosheng(Hunan University,Changsha 410082,China);Harmonic Power Measurement Based on Multi-CPU and a Phase Difference Correction Algorithm[J];Automation of Electric Power Systems;2009-11
8 TONG Ji-chun1, CHEN Wei-gen1, CHEN Rong-zhu2(1. Chongqing University, Chongqing 400044, China; 2. Wenzhou Electric Power Bureau, Wenzhou 325000, China);One Intelligent Sensor for Online Analysis of Oil-dissolved Gas in Transformer[J];High Voltage Apparatus;2004-06
9 Chen Renwei Zhu Changqing Yue Xibiao(Ordnance Engineering College,Shijiazhuang 050000);Design and realization of measurement circuit on precise true RMS[J];Electronic Measurement Technology;2010-06
10 LIU Xian-kai (Department of Information Science and Technology,Shandong University of Political Science and Law,Jinan 250014,China);Design of Portable Electric Energy Analyzer Based on CS5463[J];Control and Instruments in Chemical Industry;2009-03
【Secondary References】
Chinese Journal Full-text Database 7 Hits
1 XIAO Ji-xue,YANG Yu,WANG Kai(School of Mechanical Engineering and Automation,Xihua University,Chengdu 610039,China);An Efficient Approach to Test Power for AC Power Smart Sensor[J];Measurement & Control Technology;2010-07
2 XIAO Jixue,YANG Yu,WANG Kai,LI Shixi (School of Mechanical Engineering and Automation,Xihua University,Chengdu Sichuan 610039,China);Research on Active Power Test for AC Power[J];Machine Tool & Hydraulics;2010-14
3 LI Shi-xi,XIAO Ji-xue,WANG Kai(School of Mechanical Engineering and Automation,Xihua University,Chengdu 610039,China);Research on Estimation of Key Sampling Point in AC Power Test System[J];Control and Instruments in Chemical Industry;2010-09
4 XIAO Ji-xue,YANG Yu,WANG Kai,LI Shi-xi(School of Mechanical Engineering and Automation,Xihua University,Chengdu 610039,China);Correlation Analysis for Signal Processing in AC Power Smart Sensor[J];Measurement & Control Technology;2010-09
5 WANG Kai,XIAO Ji-xue,LI Shi-xi(School of Mechanical Engineering and Automation,Xihua University,Chendu 610039 China);Estimation of Key Sample Voltage in AC Voltage Intelligent Sensor[J];Journal of Xihua University(Natural Science Edition);2010-03
6 XIAO Ji-xue,YANG Yu,WANG Kai,LI Shi-xi (School of Mechanical Engineering and Automation,Xihua University,Chengdu 610039 China);Research on Active Power Test for AC Power Based on Correlation Analysis[J];Journal of Xihua University(Natural Science Edition);2010-04
7 XIAO Ji-xue,YANG Yu,WANG Kai(School of Mechanical Engineering and Automation,Xihua University,Chengdu 610039,China);Correlation Analysis for Signal Processing in AC Voltage Smart Sensor[J];Instrument Technique and Sensor;2010-05
China Proceedings of conference Full-text Database 1 Hits
1 Xin Zhang,Kun Yang,Cheng Zhang Tianjin Polytechnic University,Tianjin,China,300160;Intelligent Detection System Tension[A];[C];2010
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved