This paper discusses the calculation and equivalence problem of the large connected electric power system frequency dynamics. Based on the analysis of the characteristics of frequency dynamics, a co-frequency dynamic equivalence approach has been developed, in which the rotating speed of generators are used co form an RMS criterion and then the system size is reduced by aggregating the generators identified by the criterion. The approach have been compared with several other dynamic equivalence method in two systems which have different sizes. The results given have shown that the equivalent system reduced by the co-frequency method is much more accurate than the others in the calculation of frequency dynamics.
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 9 Hits
1 LIU Hong-bo1,MU Gang2,XU Xing-wei3,KE Ding-fang2,WANG Gang2,WANG Cheng-gen2 (1.School of Electrical Engineering,North China Electric Power University,Baoding 071003,Hebei Province,China;2.School of Electrical Engineering,Northeast Dianli University,Jilin 132012,Jilin Province,China;3.Northeast China Grid Company Limited,Shenyang 110006,Liaoning Province,China);Model Parameter Regulation to Make Simulated Trajectory of Power-Frequency Process Draw near Measured Trajectory Based on Trajectory Sensitivity[J];Power System Technology;2006-18
2 SUN Hua-dong1,WANG Xue-dong1,MA Shi-ying1,SUN Bin2,DU San-en1,ZHOU Chuan-mei2 (1.China Electric Power Research Institute,Haidian District,Beijing 100192,China;2.Guizhou Electric Power Dispatching and Communication Center,Guiyang 550002,Guizhou Province,China);Measures to Improve System Security and Stability for Isolated Operation of Guizhou Main Power Grid and Its Regional Power Networks[J];Power System Technology;2008-17
3 WANG Xiaoru1, LIU Yilu2 (1. School of Electrical Engineering, Southwest Jiaotong University, Chengdu 610031, China; 2. Min H Kao Departmennt of Electrical Engineering and Computer Science, The University of Tennessee,Knoxville, TN 37996-2100, USA);Analysis of Frequency Dynamics in Large-Scale Power Systems[J];Southern Power System Technology;2010-01
4 SHEN Chen,WU Jia-yun,QIAO Ying,LU Qiang,LIU Qian-jin,Christian Rehtanz (State Key Lab of Power Systems,Dept.of Electrical Engineering,Tsinghua University,Haidian District,Beijing 100084,China; ABB(China) Limited,Universal Plaza,Chaoyang District,Beijing 100016,China);Studies on Active Splitting Control of Power Systems[J];Proceedings of the CSEE;2006-13
5 SHEN Chen1, QIAO Ying1, WU Jia-yun1, LU Qiang1, LIU Qian-jin2, Christian Rehtanz 2 (1.State Key Lab of Power Systems, Dept. of Electrical Engineering, Tsinghua University, Haidian District, Beijing 100084, China; 2.ABB(China) Limited, Chaoyang District, Beijing 100016, China);Studies on the Integrated Simulation Platform Designed for Active Splitting Control of Power Systems[J];Proceedings of the CSEE;2006-18
6 JU Ping,WANG Wei-hua ,XIE Hong-jie,ZHOU Hai-qiang (Hohai University, Nanjing 210098, Jiangsu Province, China);Identification Approach to Dynamic Equivalents of the Power System Interconnected with Three Areas[J];Proceedings of the CSEE;2007-13
7 QIAO Ying,SHEN Chen,LU Qiang(State Key Lab of Control and Simulation of Power Systems and Generation Equipments(Dept.of Electrical Engineering,Tsinghua University),Haidian District,Beijing 100084,China);Islanding Decision Space Minimization and Quick Search in Case of Large-scale Grids[J];Proceedings of the CSEE;2008-22
8 QIAO Ying,SHEN Chen,LU Qiang(State Key Lab of Control and Simulation of Power Systems and Generation Equipments(Dept.of Electrical Engineering, Tsinghua University),Haidian District,Beijing 100084,China);Study on Feasibility of Islanding Control of Large-scale Power Systems[J];Proceedings of the CSEE;2008-25
9 LI Chang-gang1, LIU Yu-tian1, ZHANG Heng-xu1, ZHUANG Kan-qin2, CAO Lu2, HUANG Zhi-long2 (1. School of Electrical Engineering, Shandong University, Ji’nan 250061, Shandong Province, China; 2. East China Grid Company Limited, Huangpu District, Shanghai 200002, China);Power System Frequency Response Analysis Based on the Direct Current Loadflow[J];Proceedings of the CSEE;2009-34
【Citations】
Chinese Journal Full-text Database 1 Hits
1 Yu Yixin Zhao Guogan (Department of Electrical Engineering & Automation);IDENTIFICATION OF GROUPS OF COHERENT GENERATORS IN POWER SYSTEM TRANSIENT STABILITY STUDIES[J];Journal of Tianjin University;1987-01
【Co-citations】
Chinese Journal Full-text Database 5 Hits
1 Liu Huaidong1 Tang Xiaoling1 Gao Tianliang2 Hao Huizhen1 (1.Key Laboratory of Power System Simulation and Control of Ministry of Education Tianjin University Tianjin 300072 China 2.Yantai Dongfang Electronics Information Industry Group Co. Ltd Yantai 264000 China);An Improved Analytical Method for Determining Dynamic Security Region of Electrical Power Systems Based on Generator Coherency[J];Transactions of China Electrotechnical Society;2008-04
2 YIN Jian, XUE Fei, CHEN Yun-ping (Wuhan University, Wuhan 430072, China);Application of Grouping Theory in Forecast and Control of Transient Stability of Power Systems[J];Information On Electric Power;2002-01
3 Min Liang , Yu Yixin , Stephen T Lee , Pei Zhang ( Tianjin University, Tianjin 300072, China) (EPRI U. S. , Palo Alto, CA, USA 94303);IDENTIFICATION METHOD OF INSTABILITY MODES AND ITS APPLICATION IN DYNAMIC SECURITY REGION[J];Automation of Electric Power Systems;2004-11
4 Shan Yuanda Wan Qiulan Gao Xiaoping (Southeast University);COHERENCY CONDITION ANALYSIS[J];A Publication of the Chinese Society of Universities for Electric Power System and Automation;1992-02
5 Chen Liyi, Sun Danfeng Tianjin Universitg;Aggregation of Generating Unit Parameters in the System Dynamic Equivalents[J];Proceedings of the Csee;1989-05
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 ZHANG Yong, \ GUO Xing pu (College of Information Engineering, Beijing Technology and Business University, Beijing 100037, China);CLASSIFICATION OF SWING CURVES OF SYNCHRONOUS GENERATOR IN TRANSIENT STABILITY ANALYSIS[J];JOURNAL OF BEIJING INSTITUTE OF LIGHT INDUSRY;2000-02
2 SONG Kun~1, LI Ping~1,LIU Hong-bo~2, MU Gang~1(1.Northeast China Institute of Electric Power Engineering, Jilin 132012, China;2.North China Electric Power University, Baoding 071003, China);Determining Congestion Cost of Transmission Network by the Cost flow Method[J];Journal of Northeast China Institute of Electric Power Engineering(Natural Science Edition);2005-01
3 ZHANG Junxiao, DENG Changhong, CHEN Yunping(Wuhan University, Wuhan 430072, China);Optimizing of Equivalent Network Parameters of Power Systems Based on Least squares Estimation[J];Electric Power Science and Engineering;2004-02
4 HAN Ying-duo,JIANG Qi-rong,XIE Xiao-rong,SHEN Fei Electrical Engineering Department,Tsinghua University,Beijing 100084,China;August 14th Blackout in the US and Propose for Chinese Power System to Improving Stability and Security[J];Electrical Equipment;2004-03
5 Shan Yuanda, Wu Jie (Nanjing Institute of Technology);ON-LINE IDENTIFICATION OF COHERENT GENERATORS[J];Automation of Electric Power Systems;1986-04
6 Han Yingduo, Min Yong, Hong Shaobin (Qinghua University, Beijing);ANALYSIS OF POWER-FREQUENCY DYNAMICS IN LARGE SCALE MULTI-MACHINE POWER SYSTEMS[J];Automation of Electric Power Systems;1992-01
7 Han Yingduo, Min Yong, Hong Shaobin (Qinghua University, Beijing);THE DESIGN OF UNDER FREQUENCY LOAD SHEDDING SCHEME IN LARGE SCALE MULTI-MACHINE POWER SYSTEMS[J];Automation of Electric Power Systems;1992-01
8 Yao Liangzhong, Ni Yixin, Zhang Bomin(Tsinghua University, Beijing) Li Lingxia (Hohai University, Nanjing);FAST DIRECT TRANSIENT STABILITY ANALYSIS BASED ON DYNAMIC EQUIVALENTS OF THE LARGE SCALE POWER SYSTEMS[J];Automation of Electric Power Systems;1993-03
9 Hu Ziheng, Chen Heng H. Sasaki(Southeast University, Nanjing) (Hiroshima University, Japan);FAST ASSESSMENT OF POWER SYSTEM TRANSIENT STABILITY LIMITS[J];Automation of Electric Power Systems;1993-09
10 Teng Huan, Teng Fusheng(Sichuan Union University, 610065. Chengdu, China);THE DYNAMIC MATRIX EQUIVALENT METHOD FOR TRANSIENT SECURITY ANALYSIS IN POWER SYSTEMS[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1998-02
【Secondary References】
Chinese Journal Full-text Database 10 Hits
1 LIU Yuanqi1,2,LIU Yutian1(1.Shandong University,Jinan 250061,China;2.Shandong Electric Power Research Institute,Jinan 250002,China);An Islanding Cutset Searching Approach Based on Dispatching Area[J];Automation of Electric Power Systems;2008-11
2 LI Li,LIU Yutian (Shandong University,Jinan 250061,China);Adaptive Out-of-step Detecting Composite Criterion for Splitting Surface[J];Automation of Electric Power Systems;2009-22
3 TAN Wei,SHEN Chen,LI Ying,NI Jingmin,LIU Feng(State Key Lab of Power Systems,Department of Electrical Engineering,Tsinghua University,Beijing 100084,China);A Generator Groups Identification Method Based on Trajectory Eigenvalues[J];Automation of Electric Power Systems;2010-01
4 ZHOU Haiqiang1,HUANG Xuncheng2,WU Lei1,JU Ping1(1.Hohai University,Nanjing 210098,China;2.Henan Electric Power Dispatching and Communication Center,Zhengzhou 450052,China);Aggregation of Excitation Systems Based on Standard Transfer Functions[J];Automation of Electric Power Systems;2010-01
5 NI Jingmin,SHEN Chen,TAN Wei,LI Ying(State Key Lab of Power Systems,Department of Electrical Engineering,Tsinghua University,Beijing 100084,China);A Coherence Identifying Method Based on Linearization at Non-equilibrium Point[J];Automation of Electric Power Systems;2010-20
6 HE Renmu1,YE Jing1,LING Dun2,PANG Songling3(1.Key Laboratory of Power System Protection and Dynamic Security Monitoring and Control Under Ministry of Education,North China Electric Power University,Beijing 102206,China;2.Sanya Power Supply Bureau,Sanya 572000,China;3.Hainan Power Experimental Research Institute,Haikou 570204,China);Impacts of Load Model Parameters on System Frequency During the System Transients[J];Automation of Electric Power Systems;2010-24
7 XU Wei-dong 1;ZHANG You-jun 1;LI Peng 2 (1.Shandong Electric Power Engineering Consulting Institute,Jinan 250013,China; 2.Shandong Tancheng Electric Power Company,Tancheng 276100,China);Using PMU for State Estimates for Multi-area Interconnected Power System[J];Proceedings of the Chinese Society of Universities for Electric Power System and its Automation;2009-05
8 LIU Li-xia1,LUO Min2,LI Xiao-hui1,LIU Shu-yong1, AI Qian2,WANG Xi-tian2,CEN Hai-feng2(1.Tianjin Electric Power Corporation Technology Centre,Tianjin 300022,China; 2.School of Electronic Information and Electrical Engineering,Shanghai Jiao Tong University, Shanghai 200240,China);Comparison and Improvement of Common Methods of Dynamic Equivalence in Power System[J];Proceedings of the Chinese Society of Universities for Electric Power System and its Automation;2011-01
9 SHI Xiang1,LIU Hong-bo2,XU Xing-wei3,MU Gang1(1.Northeast Dianli University,Jilin 132012,China;2.North China Electric Power University,Beijing 102206,China;3.Northeast Grid China Company Limited,Shenyang 110006,China);Study of impact of boiler's dynamic characteristics on dynamic frequency process in power system[J];Electric Power Automation Equipment;2007-05
10 ZHANG Baohui,WANG Chenggen,HAO Zhiguo(State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University,Xi'an 710049,China);Problems and solutions of power system out-of-step islanding[J];Electric Power Automation Equipment;2010-10
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved