THE DESIGN OF ORTHOGONAL PHASOR FILTER WITH IDENTICAL MAGNITUDE-FREQUENCY CHARACTERISTICS AND OPTIONAL DATA-WINDOW

SUONAN Jia-le1, SONG Guo-bing1, XU Qing-qian1, ZHANG Jian-kang1, ZHAO Zhi-hua2 (1.Academy of Electric Engineering , Xi抋n Jiaotong University, Xian 710049, China; 2.Xuchang Relay Research Institute,Xuchang 461000, China)  
A new design method of orthogonal phasor filter is presented in this paper. The filter designed in this way has advantages as follows: Its real and imaginary parts filtering functions have identical Magnitude-Frequency Characteristics. The filtering functions have orthogonal Phase-Frequency Characteristics at the fundamental frequency. And the filters data-window can be chosen at any length. For validity testifying, a series of filters designed in this method have been used in EHV relay devices with expected effect.
【CateGory Index】: TN713
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 10 Hits
1 Yuan Yubo, Lu Yuping, Liu Zhongping (Southeast University, Nanjing 210096, China);A FAST FILTER ALGORITHM OF SHORT DATA WINDOW BASED ON PHASOR ANALYSIS[J];Automation of Electric Power Systems;2004-03
2 SUONAN Jia-le, LIU Wen-tao, ZHANG Jian-kang, SONG Guo-bing, MAO Peng, YANG Li-fan(Xi'an Jiaotong University, Xi'an 710049, China) (Dongfang Electronic Information Industry Co Ltd, Yantai 264000, China);Adaptive Distance Protection Based on Waveform Factor[J];Automation of Electric Power Systems;2005-05
3 LIU Wen-tao , SUONAN Jia-le , FU Wei , WANG Xiang-bing , LI Rui-sheng, ZHANG Ke-yuan ( Xi'an Jiaotong University, Xi'an 710049, China) ( XJ Electric Corporation, Xuchang 461000, China);Adaptive Directional Element Based on Waveform Factor[J];Automation of Electric Power Systems;2005-18
4 MAO Peng , DUAN Yu-qian , XU Yang , LI Xiao-bin Jiangsu Provincial Electric Power R & D Center, Nanjing 210036, China Southeast University, Nanjing 210096, China China Southern Power Grid Co Ltd, Guangzhou 510623, China Zhejiang University, Hangzhou 310027, China Yantai Dongfang Electronics Information Industry Co Ltd, Yantai 264001, China;Realization of Dynamic Instability Detecting Relay in High Voltage Line Protection Devices[J];Automation of Electric Power Systems;2006-02
5 SUONAN Jiale,SONG Guobing,SHAO Wenquan,SUN Dandan,ZHANG Yining(Xi'an Jiaotong University,Xi'an 710049,China);Identification of Permanent Faults Based on Differential Current Protection for Transmission Lines with Two Shunt Reactors[J];Automation of Electric Power Systems;2007-20
6 MAO Peng, BAI Richang, YANG Wei(Jiangxi Electric Power Company Extra-high Voltage Sub-company, Nanchang 330006, China);Improvement of the Inverse Time Characteristic of Distance Protection[J];Automation of Electric Power Systems;2008-06
7 WU Chonghao1,2,LU Yuping1,HOU Zhe2,LIU Xiaobao2 (1. School of Electrical Engineering,Southeast University,Nanjing 210096,China; 2. NARI Technology Development Limited Company,Nanjing 210003,China);Transient high-frequency current characteristics of UHV busbar fault and countermeasures in busbar protection[J];Electric Power Automation Equipment;2008-04
8 LUO Juan1,HUO Bing-bing1,YUN Bao-ji2 (1. Xi’an Unversity of Science and Technology,Xi’an 710054,China; 2. Xi’an Xirui Protection and Control Co.,Ltd,Xi’an 710075,China);XRB-220 adaptive busbar protection set[J];Relay;2007-16
9 SUI Xiao-yu1,ZHAO Hong2(1.Electric Engineering Department,Northwest Electric Power Staff Training Center,Xi'an 710054,China(2.Xi'an HUARUI Energy Sources Design Consulting Ltd,Xi'an 710032,China);Study on identificaiton of permanent fault for transmission lines with shunt reactors[J];Power System Protection and Control;2008-18
10 WU Jun1,WU Chong-hao2,3(1.Nanjing Power Supply Company,Nanjing 210008,China;2.Southeast University,Nanjing 210096,China; 3.NARI Technology Development Limited Company,Nanjing 210003,China);An Improved Frequency Measuring Algorithm Based on Kaiser Window Fourier Filter[J];Jiangsu Electrical Engineering;2008-04
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 ZHANG Yan-xia,WANG Liang,LIU Cui-yan(School of Electrical Engineering and Automation,Tianjin University,Tianjin 300072,China);A precise algorithm for frequency measurement of power system[J];Advanced Technology of Electrical Engineering and Energy;2006-02
2 LI Zhenran(Department of Electrical Engineering,Guangxi University);ACCORDING TO RECURSIVE LEAST SQUARE ALGORITHM AND ADAPTIVE SAMPLING TO REALIZE MICROCOMPUTER AUTOMATIC ACCURATE SYNCHRONIZER[J];ADVANCED TECHNOLOGY OF ELECTRICAL ENGINEERING AND ENERGY;1995-03
3 Shu Hongchun Gao Feng(Yunnan Polytechnic University 650051 China) Ge Yaozhong(Xian Jiaotong University 710049 China);A Practical Fault Location Algorithm for Coupled Double Circuit Line[J];TRANSACTIONS OF CHINA ELECTROTECHNICAL SOCIETY;1999-06
4 Wu Jiekang1,2,3 Long Jun1 Wang Jixiang1(1.Guangxi University Nanning 530004 China 2.Zhejiang University Hangzhou 310027 China 3.Ningbo Sanxing Group Ningbo 315104 China);An Algorithm for Power System Frequency Measurement Based on Numerical Differentiation[J];Transactions of China Electrotechnical Society;2004-04
5 Yangdonghong~1 Liu Guoqiang~2 (1.Guangdong Zhanjiang Ocean University,524088;2.Electric Branch Office under Jiangxi Xinyu Electricity Generating Co.,Ltd.);CVT medium wearing down and selecting capacitance tester[J];Electric Engineering;2003-03
6 SHEN Xiao-fan1, SU Xiao-hua2, ZHOU Chun-xia1 (1. China Electric Power Research Institute, Beijing 100085; 2. Northwest Power Network Co., Xi'an 710048, China);Influence of 750 kV Transmission Line on Protection[J];Electrical Equipment;2006-01
7 Shen Guorong;A New Directional Relay Based on the Variation of Power Frequency Components[J];Automation of Electric Power Systems;1983-01
8 Xu Jiande, Lu Yiqun (Nanjing Automation Research Institute);A NEW SCHEME OF SAMPLING SYNCHRONIZATION &. COMMUNICATION FOR DIGITAL CURRENT DIFFERENTIAL RELAY[J];Automation of Electric Power Systems;1993-04
9 Fan Yue, Shi Wei (Xi'an Jiaotong University. Xi'an 710049. China);MODIFICATION OF VOLTAGE CRITERION IN THE SINGLE-POLE AUTOMATIC RECLOSING OF TRANSMISSION LINES[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-06
10 Hu Yufeng. Chen Deshu, Yin Xianggen(Huazhong University of Science and Technology. Wuhan 430074. China);NEW DIFFERENTIAL PROTECTION OF POWER APPARATUS BASED ONSAMPLED VALUES AND ITS APPLICATION[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-10
【Secondary References】
Chinese Journal Full-text Database 10 Hits
1 SUO NAN Jia-le1,Alimjan·Kader1,2,ZHANG Yan-tao3,SUN Jin-feng3(1.School of Electrical Engineering,Xi'an Jiaotong University,Xi'an 710049,China;2.School of Electrical Engineering,Xinjiang University,Urumgi 830008,China;3.Xi'an Power Supply Bureau,Xi'an 710032,China);Study on zero-sequence current directional comparison protection of autotransformer[J];Journal of Electric Power Science and Technology;2008-04
2 HA Heng-xu , ZHANG Bao-hui ( Shandong University of Technology, Zibo 255049, China) ( Xi'an Jiaotong University, Xi'an 710049, China);New Phaselet-based Algorithm of Fast Distance Relay[J];Automation of Electric Power Systems;2005-18
3 LIU Wen-tao , SUONAN Jia-le , FU Wei , WANG Xiang-bing , LI Rui-sheng, ZHANG Ke-yuan ( Xi'an Jiaotong University, Xi'an 710049, China) ( XJ Electric Corporation, Xuchang 461000, China);Adaptive Directional Element Based on Waveform Factor[J];Automation of Electric Power Systems;2005-18
4 LI Shenghu(Hefei University of Technology,Hefei 230009,China);Power Injection Control to Operation Margin of Zone 3 Impedance Relay on Transmission Lines[J];Automation of Electric Power Systems;2006-16
5 SUONAN Jiale~1 LIU Wentao~(1,2) CHEN Yong~1 LIU Dong~1 JIAO Zaibin~1 (1.Xi'an Jiaotong University,Xi'an 710049,China) (2.Dispatching and Communication Center of China Southern Power Grid Co Ltd,Guangzhou 510623,China);Adaptive Distance Protection Based on R-L Model Error[J];Automation of Electric Power Systems;2006-22
6 LI Bin1, HE Jiali1, YANG Hongping2, HUANG Shaofeng3, QING Yingli3, XU Zhenyu3(1. Tianjin University, Tianjin 300072, China)(2. North China Power Dispatching Center, Beijing 100053, China)(3. Beijing Sifang Automation Co Ltd, Beijing 100085, China);Improvement of Distance Protection Algorithm of UHV Long Transmission Line[J];Automation of Electric Power Systems;2007-01
7 LIU Zhongping1, LU Yuping1, YUAN Yubo2(1. Southeast University, Nanjing 210096, China; 2. Jiangsu Electric Power Co, Nanjing 210036, China);Linear Anti-saturation Strategy of Digital Differential Protection for Current Transformer[J];Automation of Electric Power Systems;2007-04
8 SUONAN Jiale1, LIU Kai1, SU Xiaohua2, ZHANG Jiankang2, LI Huaiqiang2, ZHANG Yining1, KANG Xiaoning1(1. Xi’an Jiaotong University, Xi’an 710049, China;2. Northwest China Power Dispatch & Communication Center, Xi’an 710048, China);Novel Transmission Line Pilot Protection Based on Integrated Impedance[J];Automation of Electric Power Systems;2008-03
9 ZHANG Wujun, HE Benteng, ZHANG Bo(Zhejiang University, Hangzhou 310027, China);Influence of Parameter Uncertainty in Traveling-wave Differential Protection[J];Automation of Electric Power Systems;2008-03
10 MAO Peng, BAI Richang, YANG Wei(Jiangxi Electric Power Company Extra-high Voltage Sub-company, Nanchang 330006, China);Improvement of the Inverse Time Characteristic of Distance Protection[J];Automation of Electric Power Systems;2008-06
China Proceedings of conference Full-text Database 2 Hits
1 LIU Kai~(1,2),SUONAN Jia-le~2,KANG Xiao-ning~2 (1.Yantai Dongfang Electronics Information Industry Co.L,Yantai 264001,China; 2.Xi'an Jiaotong University Electrical Engineering Department,Xi'an 710049,China);A Novel Transmission Line Pilot Protection Based on integrated impedance[A];[C];2008
2 JIAO Yan-Jun YUAN Feng WU Hong-Bo Institute of Electrical Engineering,North China Electric Power University,BaoDing 071003,China. YUAN Yu-Shan HuangLong Power Company,ShanXi Local Power Group,HuangLong 715700,China;Data Processing of Protection of UHV Transmission Lines Based on Bergeron Model and Karenbauer Transform[A];[C];2008
Similar Journals
> Proceedings of the CSEE
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved