Post-fault Over-load Maloperation Countermeasure of Transmission Line Distance Protection

LIU Huanzhang1,ZHOU Zexin2(1.Central China Grid Company Limited,Wuhan 430074,Hubei Province,China; 2.China Electric Power Research Institute,Haidian District,Beijing 100192,China)  
Existing distance protection of transmission lines depends on setting calculation to avoid operation under over-load conditions.After operation of distance protection,the line load transferring to other transmission lines may result in fault expansion,so it's necessary to find some new countermeasures to avoid the mal-operation of distance protection in post-fault over-load condition.This paper proposed a new criterion to identify between over-load and fault in voltage co-ordinate instead of that in impedance co-ordinate.In the criterion,an operation area was constructed by considering compensation voltage as operation voltage and the polarization voltage as reference voltage.The protection will operate when the operation voltage is in the operation area.In the voltage co-ordinate,the load voltage is on the line between the two power source voltages,so it's easier for the protection to decide whether operate or not.The criterion can identify between fault and over-load radically and make distance protection avoid mal-operating after the load transferring.Its application will be benefit for the stability of power system.Simulation results show that the method is effective.
【CateGory Index】: TM773
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 10 Hits
1 Shen Guorong;A New Directional Relay Based on the Variation of Power Frequency Components[J];Automation of Electric Power Systems;1983-01
2 Shen Guorong, Deng Shaolong, Zhu Shengshi (Nanjing Automation Research Institute);THE NEW PRINCIPLE OF DISCRIMINATION BETWEEN POWER SWING AND SHORT CIRCUIT[J];Automation of Electric Power Systems;1990-01
3 YIN Yong-hua,GUO Jian-bo,ZHAO Jian-jun,BU Guang-quan (China Electric Power Research Institute,Beijing 100085,China);PRELIMINARY ANALYSIS OF LARGE SCALE BLACKOUT IN INTERCONNECTED NORTH AMERICA POWER GRID ON AUGUST 14 AND LESSONS TO BE DRAWN[J];Power System Technology;2003-10
4 GE Rui,DONG Yu,Lü Yue-chun (National Electric Power Dispatching and Communication Center,Xicheng District,Beijing 100031,China);Analysis of Large-Scale Blackout in UCTE Power Grid and Lessons to be Drawn to Power Grid Operation in China[J];Power System Technology;2007-03
5 ZHANG Hua1,ZHENG Tao2,XIAO Shi-wu2,LIU Wan-shun2,HUANG Shao-feng2,ZHANG Da3 (1.Substation Operation Filiale of Beijing Electric Power Company,Xicheng District,Beijing 100031,China; 2.Key Laboratory of Power System Protection and Dynamic Security Monitoring and Control(North China Electric Power University),Ministry of Education,Changping District,Beijing 102206,China; 3.UHV Power Transmission Filiale of Shandong Electric Power Corporation,Jinan 250021,Shandong Province,China);A Recognition Algorithm for Fault Occurred during Oscillation of UHVAC Power Transmission System Based on Fault Entropy of Current Signal Envelops[J];Power System Technology;2008-19
6 LIU Huan-zhang (Huazhong Electric Power Dispatch & Communication Bureau, Wuhan 430077, China);A NOVEL IMPEDANCE PROTECTION ANALYSIS METHOD BASED ON THE TRANSFORM FROM THE VOLTAGE PLANE TO THE IMPEDANCE PLANE[J];Proceedings of the Csee;2004-01
7 HU Yu-feng1,LIU Huan-zhang2(1.GuangDong Power Grid Company Foshan Power Supply Bureau Dispatch Center,Foshan 528000,Guangdong Province,China;2.Huazhong Power Dispatch & Communication Center,Wuhan 430074,Hubei Province,China);Study on Distance Relay Based on Pre-Fault Compensated Voltage[J];Proceedings of the CSEE;2006-16
8 SHEN Bing,HE Ben-teng (College of Electrical Engineering Zhejiang University,Hangzhou 310027,Zhejiang Province,China);A Novel Adaptive Distance Protection Based on Impedance Locus Estimation[J];Proceedings of the CSEE;2007-31
9 ZHOU Yun-hai1,LIU Ying-shang2,HU Xiang-yong1 (1. College of Electrical Engineering and Information Science,China Three Gorges University,Yichang 443002,Hubei Province,China; 2. China Southern Power Grid Co.Ltd,Guangzhou 510620,Guangdong Province,China);Power System Network Reconstruction After Blackout[J];Proceedings of the CSEE;2008-10
10 SUONAN Jiale, HE Fangming, JIAO Zaibin, WANG Zhien, HOU Zhuo, LIU Renhuan (School of Electric Engineering, Xi’an Jiaotong University, Xi’an 710049, Shaanxi Province, China);Research on the Characteristics of Distance Element Based on the Power-frequency Voltage and Current Variation[J];Proceedings of the CSEE;2010-28
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 XU Gen-yang(Chi Zhou Power Supply Company,Chi Zhou 247000,China);Application of General Relay Protection Equipment Check Management System[J];Journal of Anhui Electrical Engineering Professional Technique College;2006-01
2 FANG Xue-lei1,ZHU Ning2(1.Anhui Electric Power Training Center,Hefei 230022,China;2.Tongling Power Supply Company,Tongling 244002,China);Analysis and Comparision Transmission Line Breakdown Localization Techniques[J];Journal of Anhui Electrical Engineering Professional Technique College;2008-03
3 ;A special problem of one and a half connection high frequency protection[J];Anhui Electric Power;2004-02
4 ;Power System Control Based on Voltage Risk[J];Anhui Electric Power;2009-01
5 ZHU Guang-wei(Measure and Control Devece Work,Benxi Steel Co.Ltd Benxi,Liaoning,117021,China);The Application of Computer-supported Relay Protection to Power Systems for Enterprises and Its Development[J];Journal of Liaoning Institute of Science and Technology;2006-03
6 YANG Fan(Shapingba Power Supply Bureau,Chongqing Electric Power Company,Chongqing 400030,China);Synthesized Digital Relay Protection Device Based on DSP[J];Journal of Chongqing Institute of Technology(Natural Science);2009-03
7 ZHANG Yong (GuangDong Power Engineering Co. ; GuangZhou 510730);Discussion of Architecture and Application of Transformer Protection[J];Journal of Chongqing Electric Power College;2003-04
8 CAO Yun-xuan1,2,TANG Jian-jun1,HU Peng-cheng1,SHEN Yu-mei1,YANG Yu-lu1,2 (1.Changshou Supply Bureau,Chongqing Electric Power Company,Chongqing 401220,China;2.Hubei University,Wuhan Hubei 430068,China);Analysis on Surge Caused by Fiber Optical Current Differential Protection and Improvement Measures[J];Journal of Chongqing Electric Power College;2009-04
9 YUAN Zhao-qiang,WU Qiang(College of Electrical Engineering and Information Science,China Three Gorges University,YiChang 443002,China);Method of Setting of the Self-adaptive Relay Protetction[J];Journal of Changsha University of Electric Power(Natural Science);2006-04
10 YIN Xiang-gen,WANG Yang,ZHANG Zhe,WEN Ming-hao(Electric Power Security and High Efficiency Lab,Huazhong University of Science and Technology,Wuhan 430074,China);Limited wide area intelligent protection for coping with power network catastrophe[J];Journal of Electric Power Science and Technology;2008-04
China Proceedings of conference Full-text Database 10 Hits
1 Wu Da-li,Yin Xiang-gen,Zhang Zhe,Zhang Zhong-qing (Electric Power Security and High Efficiency Lab, Huazhong University of Science and Technology,Wuhan,China);Research on Multi Differential Protection Scheme for Transmission Line[A];[C];2007
2 DONG Ye,CHEN Gang-jie (North China Electric Power University,Beijing 102206,China);STUDY ON FAULT COMPONENT OF TRANSIENT CURRENT FOR UHV TRANSMISSION LINES[A];[C];2007
3 FANG Zhu BAI Xiao-min DING Jian LI Zai-hua ZHOU Zi-guan (China Electric Power Research Institute,Haidian District,Beijing 100085,China);Dynamic Search Arithmetic for Key Transmission Section of Power System[A];[C];2007
4 ZHANG Hua LIU Wanshun ZHENG Tao YANG Qing(Key Laboratory of Power System Protection and Dynamic Security Monitoring and Control under Ministry of Education (North China Electric Power University),Changping District,Beijing 102206,China);STUDY ON THE DISDINGUISHING FAULT IN OSCILLATION BASED ON THE ALGORITHM OF COMPREHENSIVE VECTOR AND MORPHOLOGY[A];[C];2006
5 ZHANG Hua ZHENG Tao XIAO Shiwu LIU Wanshun HUANG Shaofeng ZHANG Da(Key Laboratory of Power System Protection and Dynamic Security Monitoring and Control under Ministry of Education (North China Electric Power University),Changping District,Beijing 102206,China[1],Super-HV Company of Shan Dong Electric Power Corporation,250001,China[2];STUDY ON THE DISDINGUISHING FAULT IN OSCILLATION BASED ON THE FAULT ENTROPY ALGORITHM OF ENVELOPES OF CURRENT SIGNALS[A];[C];2006
6 JIN Qichao~1 JI Yongping~1 WEI Dong~2 LIU Minghui~1 ZHANG Tiantian~1(1.Nanjin Nanzi Electric Power Control System Co.,LTD.,Nanjing 210003,China;2.Nanjin Talent Electric Co.,LTD.,Nanjing 211800,China);Optimized realization of fix-point algorithm of protection relay Based on DSP[A];[C];2006
7 WangLei Jimusi(ZhuHai Wanlida Electric Co.,Ltd,Guangdong,Zhuhai,519085);Analysis of Modern Relay Protection And Auxiliary Power Automation[A];[C];2006
8 ZHAO Xiao-ming~1 WU jun~1 YU Zhi-hui~2(1.ZheJiang Electric Power Test and Research Institute,Hang Zhou 310014,China;2.ZheJiang Hang Zhou Electric Power Bureau,Hang Zhou 310016,China);The Improvement of Bus Differential Relay REB103 Security Application[A];[C];2006
9 Liu Hui(Chaohu Electric Power Company,Chaohu 238005,Anhui Province);The Reason And Countermeasure Of Gas Protection Action In Power Transformer[A];[C];2006
10 WANG Xing-guo HUANG Shao-feng Key Laboratory of Power System Protection and Dynamic Security Monitoring and Control under Ministry of Education,North China Electric Power University,Beijing 102206,China;Study on Fault Transient Component of Long Distance Transmission Lines[A];[C];2008
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 Li Jinmin(Department of Electrical Engineering)Zhai Ji Guo Biao(Shentou Power plant I);THE ANALYSIS OF CALCULUS IN MICROPROCESSOR-BASED PROTECTION[J];Journal of Electric Power;1995-01
2 Shen Guorong;A New Directional Relay Based on the Variation of Power Frequency Components[J];Automation of Electric Power Systems;1983-01
3 Xie Baoyan (Electric Power Research Institute,P.R.C.);ANALYSIS & DISCUSSIONS ON THE SWING-BLOCKING SCHEME FOR SOME FOREIGN-MADE LINE PROTECTION EQUIPMENT[J];Automation of Electric Power Systems;1989-04
4 Ge Yaozhong,Du Zhaoqiang,L iu H aofang Xi' an Jiaotong U niversity,Xi' an 710 0 4 9,China;ANALYSISON PERFORMANCE OF THE ADAPTIVE INSTANTANEOUSTRIP PROTECTION[J];Automation of Electric Power Systems;2001-18
5 Zong Hongliang 1, Ren Zuyi 1, Zheng Yuping 1, Shao Xuejian 2, Sun Guanghui 1, Shen Guorong 1 (1. Nanjing Automation Research Institute, Nanjing 210003, China) (2. Hangzhou Electric Power Bureau, Hangzhou 310009, China);A OUT-OF-STEP SPLITTING DEVICE BASED ON THE CHANGING TRACK OF THE VOLTAGE OF OSCILLATION CENTER[J];Automation of Electric Power Systems;2003-19
6 Lin Xiangning 1, Liu Pei 1, Hu Fan 2 (1. Huazhong University of Science and Technology, Wuhan 430074, China) (2. China Southern Power Grid Co Ltd, Guangzhou 510620, China);COMPLETE POWER SYSTEM OSCILLATION SIMULATION FOR RELAY PROTECTION RESEARCH[J];Automation of Electric Power Systems;2003-22
7 LI Jun, LIU Yan, GU Xue-ping (North China Electric Power University, Baoding 071003, China);An Entropy-based Discretization Method Applied in Transient Stability Assessment[J];Automation of Electric Power Systems;2005-08
8 LEI Ya-zhou , Gordon LIGHTBODY ( ESB National Grid, Ireland; University College Cork, Ireland);Wind Energy and Electricity Market[J];Automation of Electric Power Systems;2005-10
9 LIU Huan-zhang, XU Qing-qiang (Huazhong Electric Power Dispatch & Communication Bureau, Wuhan 430070, China) (Xi'an Jiaotong University, Xi'an 710049, China) (Jiangsu Electric Power Research Institute, Nanjing 210036, China);High Performance Starting Element Based on Three-phase Simultaneous Sampling Values[J];Automation of Electric Power Systems;2005-22
10 XU Qing-qiang , SUONAN Jia-le , LIU Huan-zhang , XU Yang (Xi'an Jiaotong University, Xi'an 710049, China) (Jiangsu Electric Power Research Institute Corporation Limited, Nanjing 210036, China) (Huazhong Electric Power Dispatch &. Communication Bureau, Wuhan 430070, China);Fault Phase Selector for HV Transmission Line Protective Relaying Based on the Characteristic of the Arc Voltage Between Two Faulted Phases[J];Automation of Electric Power Systems;2006-04
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved