The PSS parameters optimization based-on power system operating variables

HUANG Mei, HAN Hui-yun(School of Electrical and Engineering, Beijing Jiaotong University, Beijing 100044,China)  
Whether or not PSS has fine damping capacity within the frequency band of the low frequency oscillation, the key is parameters setting. For PSS field-testing and parameters setting, the PSS parameters are verified using maximum and minimum operational conditions, to make PSS having the more perfect compensation effect when low frequency oscillation. With the bus fed static excitation system, based on field-test data and using frequency domain analysis, the hysteretic characteristics of excitation system were given, the influence of operating variables on hysteretic characteristics of excitation system was analyzed. The PSS parameter optimization based-on power system operating variables was presented, which made PSS having the good compensation effect in various operation mode, and combined with the practical example, the hysteretic characteristics of excitation system for engineering requirements can be satisfied by optimized operational parameters.
【CateGory Index】: TM44;TM732
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 3 Hits
1 SU Wei-min,FANG Si-li (North China Hectric Power Research Institute Company, Beijing 100045,China; China Electric Power Research Institute, Beijing 100085,China);Typical Mathematics Model and Its Parameter Option for Excitation System[J];Electrical Equipment;2004-11
2 ;Power System Stabilizer Parameter Calculation and Method of Debugging[J];ELECTRIC POWER;2000-06
3 <author>NG Si-li,SU Wei-min (Electric Power Research Institute, Beijing 100085, China; North China Electric Power Research Institute , Beijing 100045, China);<title>sposition, configuration, parameter calculation and commissioning of PSS[J];Electric Power;2004-10
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 ;Test and Parameter-Setting of 600MW Units of Power System Stabilizer(PSS)[J];Anhui Electric Power;2008-01
2 ;Based on EX2100 Generator Excitation System modeling and Setting of PSS Parameters[J];Anhui Electric Power;2010-01
3 ;Research on Close-Loop Test for Automatic Voltage Regulator of Large Unit[J];Anhui Electric Power;2011-02
4 ZHOU Min(Sichuan Electric Vocational and Technical College,Chengdu Sichuan 610072,China);Parameter Optimization of a Power System Stabilizer Based on PSO Algorithm[J];Journal of Chongqing Electric Power College;2010-03
5 KONG Dening,ZHU Huaiying,LI Zhenjiang,Zhang Yan(Longtan Hydropower Plant,Tian'e 547300,China);Application of Integrated Automation System to Longtan Hydropower Station[J];Hydropower Automation and Dam Monitoring;2008-04
6 HE Weiguo,HUA Guanghui,LI Zhen,ZHOU Feng(State Grid Electric Power Research Institute,Nanjing 210003,China);Design of Large Pumped Storage Units Excitation System[J];Hydropower Automation and Dam Monitoring;2011-03
7 CHEN Jie,JIANG Jian-guo(Key Lab of Control of Power Transmission and Transformation,Ministry of Education,Dept.of Electrical Engineering,Shanghai Jiaotong University,Shanghai 200240,China);Research on SVC Controller for SSR Mitigation Based on MATLAB[J];Electrical Measurement & Instrumentation;2011-04
8 Han Huiyun (Beijing Jiaotong University);Effect of Operational Parameters on Bus Fed Static Excitation System Hysteretic Characteristics[J];Electrotechnical Application;2006-01
9 Ge Yuanbao(Datang Huaibei Power Plant);Fit Issues between Low Excitation Limit of Regulator and Field Failure Protection of Generator[J];Electrotechnical Application;2008-13
10 GUO Qing-yang1,LI Qing-xian2,WANG Wen-jie2(1.Dispatching Center Under Heilongjiang Electric Power Co.LTD,Harbin 150001,China;2.The Third Power Plant of Harbin, 150024, China);The Reasons Caused Low Frequency Oscillation Betweenthe No3 Generator of the Third Power Plant of Harbin and the Power System[J];Large Electric Machine and Hydraulic Turbine;2002-05
China Proceedings of conference Full-text Database 5 Hits
1 Xun Jihui Xiong Shangfeng (Hunan Electric Power Test & Research Institute,Changsha,Hunan,410007);Analysis and Practice of Excitation System Model for Power System Stability Studies[A];[C];2008
2 LIU Yun, DUAN Cai-li (Datang Shentou Second Power Plant, Shuozhou 036011, Shanxi Province, China);Study on Excitation Regulation System of Large Generator[A];[C];2006
3 ZHAO Qi-ming JIANG Wei-min LIU Yu ( JianBi power plant,Guodian Group Zhenjiang 212006,China );Alteration for generator excitation regulation equipment of JianBi power plant,Guodian Group[A];[C];2009
4 YANG Ming,XU Qipin,DENG Xiaojun,XU Rong,(NARI Technology Development Co.Ltd.,Nanjing 210061,China);Research on power system damp controller based on excitation system[A];[C];2013
5 ;UNITROL 5000励磁调节器中发电机转子接地保护的应用[A];[C];2013
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 LI Zhi-jun,YANG Mei,LIU Yan-ping,FAN Xiao-dong (Hebei University of Technology, Tianjin 300130, China);Research in Several Aspects of Synchronous Machine Simulation Based on MATLAB[J];Large Electric Machine and Hydraulic Turbine;2003-06
2 DING Zhi-dong,LIU Guo-hai(School of Electrical & Information Engineering,University of Jiangsu,Zhenjiang 212013,China);Research of Influence of Synchronous Generator Excitation on Power System Stability[J];Large Electric Machine and Hydraulic Turbine;2007-04
3 JIANG Si-dong,LIU Jue-min,DU Zong-lin,WANG Cheng-fu,CHU Wen-bin(College of Electrical Engineering & Information Technology,Hunan University,Changsha 410082,China);Modeling and Simulation of Digital Excitation Regulator in Power System[J];Large Electric Machine and Hydraulic Turbine;2008-03
4 YANG Mei,LI Zhi-jun,LIU Yan-ping,LI Shao-hui,FAN Xiao-dong(Hebei University of Technology,Tianjin 300130,China);Power system stabilizer parameter tuning based on Matlab[J];Electric Power Automation Equipment;2004-05
5 WANG Yang-zheng,JIANG Ping(Southeast University,Nanjing 210096,China);Parameter optimization of excitation system based on constrained nonlinear programming[J];Electric Power Automation Equipment;2007-05
6 WANG Jian-cheng,ZHANG Tao,WANG Qi-wen,SHANG You-ming (Nuclear Power Qinshan Joint Venture Co.,Ltd.,Haiyan 314300,Zhejiang Province,China);TESTING AND ANALYSIS OF THREE PHASE CURRENT UNBANLANCE AT 500kV OUTLET OF THE 2nd QINSHAN NUCLEAR POWER PLANT[J];Power System Technology;2005-05
7 WANG Shu-zhong,LIU Yu-zhuo,WU Zhong(Shanxi Electric Power Research Institute,Taiyuan,Shanxi 030001,China);Site Test and Check about Electric Power System Stebility Model and Parameter[J];Shanxi Electric Power;2006-01
8 TAN Yong-qiang(Guangdong Yuelong Power Generation Co.,Ltd.,Luoding,Guangdong 527200,China);Test and analysis on power system stabilizer in Dingneng Power Plant[J];Guangdong Electric Power;2006-08
9 Han Hui-yun,Huang Mei (Beijing Jiaotong University,School of Electrical and Engineering,Beijing 100044,China);Power System Low Frequency Oscillation & PSS Analysis[J];North China Electric Power;2005-07
10 Li Quan(Sanhe Power Generation Co.Ltd.,Beijing 065201,China);Test and Data Measurement of Electric Power System Stabilizer[J];North China Electric Power;2006-01
【Secondary Citations】
Chinese Journal Full-text Database 5 Hits
1 FANG Si-li, SU Wei-min China Electric Power Research Institute, Beijing 100085, China;North China Electric Power Research Institute, Beijing 100045, China;Analysis of Relevant Specifications for Dynamic Performance Index of Excitation System[J];Electrical Equipment;2004-07
2 ;PSS Commissioning Test and Calculation Analysis for 200 MW Unit Ming Tomb Pumped Storage Station[J];ELECTRIC POWER;1999-11
3 ;Power System Stabilizer Parameter Calculation and Method of Debugging[J];ELECTRIC POWER;2000-06
4 ;Digital Simulation of Excitation System and Power System Stabilizer and Its Field Test in Guangxi[J];ELECTRIC POWER;1999-03
5 ;Summary of Tests of PSS in Zhejiang Electric Power System[J];ZHEJIANG ELECTRIC POWER;2000-01
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved