Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Chinese Journal of Ultrasonography》 2005-12
Add to Favorite Get Latest Update

Evaluation of elastography application in differentiating benign and malignant breast tumors

WANG Yi~*,WANG Yong,ZHANG Xi-min,QIN Qian-miao,WANG Yi-da,XU Zhi-zhang.~*Department of Ultrasound,Huashan Hospital,Fudan University,Shanghai 200040,China  
Objective To evaluate the elastography application in differentiating benign and malignant breast tumors.Methods Elastography was conducted on 110 patients with 115 breast tumors to differentiate benign tumors from malignant tumors,and the results were compared with those by post-operative pathology.Results Accuracy of elastography in differentiating breast tumors was(84.3)%(97/115),while the sensitivity was(78.8)%(26/33),the specificity was(86.6)%(71/82).Conclusions Elastography is a new valuable ultrasonographic method in differentiating benign and malignant breast tumors,especially when the mass is not clearly defined with irregular contour.
【CateGory Index】: R445.1
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 10 Hits
1 Yuan Ying, Gong Weibing, Zhang Shouhua, Sun Yu, Wang QianDeparment of Ultrasound,Nanfang Hospital,Nanfang Medical Univevsity,Guangzhou 510515, China;Primary study on the diagnostic value of elastic imaging on partial cholestatic hepatic fibrosis in rats[J];Journal of Ultrasound in Clinical Medicine;2007-06
2 SHEN Jianhong1, LUO Baoming2, OU Bing2, et al 1.Department of Imaging, The Second Affiliated Hospital, Guangzhou University of TCM, Guangzhou 510120; 2.Department of Ultrasound in Medicine, The Second Affiliated Hospital, Sun Yat-sen University, Guangzhou 510120 Corresponding author: Luo Baoming;The value of ultrasonic elastography for differentiating malignant and benign mass of breast[J];Lingnan Modern Clinics in Surgery;2006-05
3 WANG Zhiyuan1,YANG Tongming1,WU Zehui1,TANG Shichu1,LIANG Xia1,QIN Ang1,OUYANG Tao1,LIU Pengfei1,LIU Jun2(1.Department of Ultrasound,Hunan Tumor Hospital,Changsha 410006;2.Department of Image,Second Xiangya Hospital,Central South University,Changsha 410011,China);Correlation between elastography score and strain rate ratio in breast small tumor[J];Journal of Central South University(Medical Science);2010-09
4 (XU Youfeng,CHEN Libin,MAO Feng,CAO Yong,LU Jian,DING Gaofeng.The first hospital of Ningbo,Zhejiang 315010,China.);The value of realtime ultrasonic elastography in differentiating the elderly breast malignant lesions from the benign[J];Chinese Journal of Geriatric Care;2011-01
5 QU Jian-feng,LIU Fen-ru,TU Rui,et al.(Department of Ultrasound,Xinyang Central Hospital,Xinyang Henan 464000,China);Diagnostic Value of Ultrasound Elastography and Comprehensive Ultrasound Evaluation of Breast Masses[J];Journal of Henan Medical College for Staff and Workers;2011-01
6 Fu Lina,Wang Yi,Wang YongDepartment of Ultrasound, Huashan Hospital, Fudan University;Ultrasound Elastography and Two-dimensional Ultrasound Imaging:Combined Application in Differentiating Benign Breast Lesions from Malignant[J];Chinese Computed Medical Imaging;2007-02
7 LUO Bao-ming,OU Bing,ZHI Hui Department of Ultrasound,the Second Affiliated Hospital,Sun Yat-sen University,Guangzhou 510120,China;Factors Affecting the Performance of Ultrasonic Elastography in Breast Tumors and Its Solutions[J];Acta Academiae Medicinae Sinicae;2008-01
8 JIANG Shu-hong,JI Sheng-zhang.(Department of Radiology,Tianjin Fourth Central Hospital,Tianjin 300140,China);Value of Ultrasonography in the Diagnosis of Breast Masses[J];Medical Recapitulate;2010-18
9 WANG Zhi-yuan1,YANG Tong-ming1,WU Ze-hui1,TANG Shi-chu1,PENG Ji-lan,LIANG Xia1,LIU Peng-fei1,LIU Jun2(1.Instittute of Ultrasound and Endoscopy,Hunan Toumor Hospital,Changsha 410006,China; 2.Department of Radiology,the Second Xiangya Hospital of Center South University,Changsha 410011,China);Ultrasonic elastography in differentiating benign and malignant small breast tumors[J];Chinese Journal of Medical Imaging Technology;2010-10
10 FAN Xiao-fang1,DING Yong-jun1,WANG Wei-li2,SUN Wei-jian1,KANG li1 1.Department of Diagnostic Imaging,Fourth Affiliated Hospital Suzhou University,Wuxi 214062,P.R.China2.Department of General Surgery,Fourth Affiliated Hospital Suzhou University,Wuxi 214062,P.R.China;Discuss the value of color Doppler flow imaging,Ultrasonic elastography and mammography in breast disease[J];Journal of Medical Imaging;2010-10
【Citations】
Chinese Journal Full-text Database 1 Hits
1 XU Zhizhang,YU Qing. Fu Dan University Institute of Medical Ultrasound and Engineering, Department of Diagnostic Ultrasound, Zhong Shan Hospital of Fu Dan University;Principles and preliminary application of elastosonography[J];Shanghai Medical Imaging;2005-01
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 SHEN De-juan reviewing,YANG Bin checking(Department of Ultrasound,Nanjing General Hospital of Nanjing Military Command,PLA,School of Medicine,Nanjing Uiniversity,Nanjing 210002,Jiangsu,China);Prospect and diagnosis of sonography in breast cancers[J];Journal of Medical Postgraduates;2007-02
2 SHEN Jianhong1, LUO Baoming2, OU Bing2, et al 1.Department of Imaging, The Second Affiliated Hospital, Guangzhou University of TCM, Guangzhou 510120; 2.Department of Ultrasound in Medicine, The Second Affiliated Hospital, Sun Yat-sen University, Guangzhou 510120 Corresponding author: Luo Baoming;The value of ultrasonic elastography for differentiating malignant and benign mass of breast[J];Lingnan Modern Clinics in Surgery;2006-05
3 LI Yin-yan,WANG Xue-mei,ZHANG Yi-xia,OU Guo-cheng (Department of Ultrasound,the First Affiliated Hospital of China Medical University,Shenyang 110001,China);The application value of score by ultrasound elastography at fatty liver graduation[J];Journal of China Clinic Medical Imaging;2009-12
4 REN Xin-ping,ZHAN Wei-wei,ZHOU Ping,ZHOU Jian-qiao.The Department of Ultrasound,Ruijin Hospital,Medical School of Jiaotong University,Shanghai 200025,P.R.China;Preliminary Study of Real-Time Elastography in the Diagnosis of Lymph Node Diseases[J];West China Medical Journal;2010-02
5 HUANG Jun-hong1,XIA Shi-wen2,SONG Fei2,YANG Xiao-hong1,XU Yang-qing1,CHEN Xin-lin1(1.Department of Ultrasound,2.Department of Neonatology,Hubei Maternal and Children Health Care Hospital,Wuhan 430070,China);Ultrasound acoustic radiation force impulse imaging assessment of brain injury in prematures with asphyxia[J];Chinese Journal of Interventional Imaging and Therapy;2010-04
6 Wang Yi,Wang Yong,Zhang Ximin,et al Department of Utrasound,Huashan Hospital,Fudan University,Shanghai200040;Correlation of Elastography and Clinical Breast Examination about Breast Tumors[J];Chinese Computed Medical Imaging;2006-01
7 LIN Yi-han~1,CHEN Si-ping~2;Medical ultrasound imaging and development[J];Chinese Journal of Medical Device;2006-06
8 YU Qing,XU Zhizhang,MAO Feng,et al. Department of Diagnostic Ultrasound,Zhongshan Hospital of Fudan University, Shanghai, 200032;Preliminary application of elastosonography in diagnosis of breast diseases[J];Shanghai Medical Imaging;2005-02
9 Ren Xinping,Zhan Weiwei,Zhou Ping,et al Department of Ultrasound,Ruijin Hospital,Medical School of Jiaotong University,Shanghai 200025 China;Comparative Study of Real-time Elastography and Grey-scale Ultrasonography in the Diagnosis of Thyroid Occupied Lesions[J];Chinese Journal of Ultrasound in Medicine;2009-02
10 YANG Ning-jing~* ZHAO Li-ming~* SONGBin~*. *De- partment of Radiology,West China Hospital of Sichuan University,Chengdu 610041,China;Review of Advances in Imaging Evaluation of Liver Fibrosis[J];Chinese Journal of Bases and Clinics in General Surgery;2008-03
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 QIAN Chao-wen,XU Dong,BIAN Ye-ping, ZHAO Hui-zheng,CHEN Li-yu (Department of Ultrasound,Zhejiang Cancer Hospital,Hangzhou310022,Zhejiang,China);Application of Three-Dimen-sional Ultra sonography in Breast Cancer[J];Carcinogenesis,Teratogenesis and Mutagenesis;2005-06
2 LUO Jianwen, BAI Jing. Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing\ 100084;Finite Element Analysis in Simulations of Ultrasound Elastography[J];Beijing Biomedical Engineering;2003-02
3 XING Zhanfeng, L Yangsheng. Department of Biomedical Engineering, School of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin\ 300072;Fuzzy Multiscale Edge Detection and Its Application for Medical Ultrasonic Images[J];Beijing Biomedical Engineering;2003-03
4 LUO Jianwen BAI Jing Department of Biomedical Engineering,Tsinghua University,Beijing 100084;Solution for the Inverse problem of ultrasound elastography using radial compression[J];Beijing Biomedical Engineering;2007-02
5 HA Zhang1,LI Chuanfu2,WANG Jinping2,ZHOU Kangyuan1,HE Li1 1 Department of Electronic Engineering and Information Sciences,University of Science and Technology of China,Hefei 230027;2 First Affiliated Hospital of Anhui Traditional Chinese Medical College,Hefei 230031;Multi-characteristics recognition of breast tumor ultrasound images combining with elasticity parameters[J];Beijing Biomedical Engineering;2008-06
6 Yan Songli,Qin Shisheng,Tang Binghui Department of Ultrasound,3rd Hospital of Nanchang,Nanchang 330002 China;Differential Diagnosis Between Breast Carcinoma and Breast Fibroadenoma on Color Doppler Ultrasonography[J];Chinese Journal of Ultrasound Diagnosis;2004-02
7 Lin Xi,Wang Yue,Li Anhua,et alDepartment of Ultrasound,Cancer Center of Sun Yetsen University,Guangzhou 510060 China;Ultrasonic Diagnosis of Mammary Cancer Without Visible Lumps in Molybdenum Target:Comparison With X-ray[J];Chinese Journal of Ultrasound Diagnosis;2005-08
8 Chen Libin,Xu Youfeng,Chao Yong,et al Ningbo No.1 Hospital Ningbo 315000 China;Diagnostic Value in Grading Breast Cancer[J];Chinese Journal of Ultrasound Diagnosis;2005-11
9 LUO Jian wen,BAI Jing (Department of Biomedical Engineering,School of Medicine,Tsinghua University,Beijing 100084,China);The principle and theoretical analysis of ultrasound elastography[J];Foreign Medical Biomedical Engineering Fascicle;2003-03
10 XU Tao , YE Zhi-qian , CAI Wei-min . Clinical Engineering Institute , Zhejiang University, Hangzhou 310006, China; Institute of Infectious Diseases , First Affiliated Hospital , Zhejiang University , Hangzhou 310003 , China;Texture analysis methods used in B-scan liver images[J];International Journal of Biomedical Engineering;2006-04
【Secondary References】
Chinese Journal Full-text Database 10 Hits
1 LI Yin-yan,WANG Xue-mei,ZHANG Yi-xia,OU Guo-cheng (Department of Ultrasound,the First Affiliated Hospital of China Medical University,Shenyang 110001,China);The application value of score by ultrasound elastography at fatty liver graduation[J];Journal of China Clinic Medical Imaging;2009-12
2 ZHANG Da-kun1,ZHANG Xin-li1,LI Zhi-yan1,CHEN Min1,FENG Hui1,LI Meng1,DONG Zheng1,ZHAO Yuan-yuan2(1.Department of Ultrasound,the 302 Hospital of PLA,Beijing 100039,China;2.Department of Ultrasound,Qingdao Municipal Hospital,Qingdao Shandong 266071,China);Quantitative evaluating the degree of diffuse fatty liver by acoustic radiation force impulse imaging:a pilot clinical study[J];Journal of China Clinic Medical Imaging;2010-10
3 QU Jian-feng,LIU Fen-ru,TU Rui,et al.(Department of Ultrasound,Xinyang Central Hospital,Xinyang Henan 464000,China);Diagnostic Value of Ultrasound Elastography and Comprehensive Ultrasound Evaluation of Breast Masses[J];Journal of Henan Medical College for Staff and Workers;2011-01
4 Xu Qiuhua,Yan Shan,Yuan Fang,et al Department of Ultrasound,Ninth People's Hospital,Shanghai Jiaotong University Medical College,Shanghai 200011 China;Ultrasound Characteristics of Breast Infiltrated Ductal Carcinoma[J];Chinese Journal of Ultrasound in Medicine;2008-05
5 ZHONG Wen-jing LUO Bao-ming Department of Ultrasound in Medcine, Second Affiliated Hospital, Sun Yat-Sen University (Guangzhou 510120);The Application of Ultrasonic Elastography in Diagnosis of Breast Diseases[J];China Medical Device Information;2008-04
6 ZHAO Zi-zhuo LUO Bao-ming Department of Ultrasound in Medcine, Second Affiliated Hospital, Sun Yat-Sen University (Guangzhou 510120);The Principle and Techniques of Ultrasonic Elastography[J];China Medical Device Information;2008-04
7 YANG Ning-jing~* ZHAO Li-ming~* SONGBin~*. *De- partment of Radiology,West China Hospital of Sichuan University,Chengdu 610041,China;Review of Advances in Imaging Evaluation of Liver Fibrosis[J];Chinese Journal of Bases and Clinics in General Surgery;2008-03
8 ZHOU Ping,ZHAN Wei-wei,REN Xin-ping,ZHOU Jian-qiao,CHEN Man (Department of Ultrasound,Shanghai Ruijin Hospital,Shanghai Jiaotong Univercity,Shanghai 200025);Value of Elastosonography in the Diagnosis of Thyroid Nodules[J];Chinese Journal of Medical Imaging;2009-04
9 LI Yin-yan,WANG Xue-mei,ZHANG Yi-xia,OU Guo-cheng(Department of Ultrasound diagnosis,The First Affiliated Hospital,China Medical University,Shenyang 110001,China);Preliminary Study on Quantitative Analysis of Fatty Liver by Ultrasound Elastography[J];Journal of China Medical University;2009-08
10 Liu Lei,Su Linan,Wang Qian,Liu Jing Department of Biomedical Engineering,School of Medicine,Tsinghua University,Beijing,100084;Simulating Experimental Study on Ultrasonic Elastography Based Monitoring of Cryosurgery[J];Chinese Journal of Medical Instrumentation;2010-04
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved