Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Bulletin of Chinese Cancer》 2004-09
Add to Favorite Get Latest Update

An Analysis of Routine Quality Test for Conventional Simulator

LIANG Shao-hua, DENG Xiao-wu, CHEN Jian-yi,et al.  
【CateGory Index】: TH77
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 2 Hits
1 DENG Xiao-wu;Quality Control and Quality Assurance for Radiotherapy[J];China Cancer;2008-08
2 Ni Liang Department of Medical Equipment Management,Jianghan Oil Group General Hospital,Qianjiang 433124,China;Use and maintenance of Fm—Ⅱ simulator[J];China Medical Equipment;2010-01
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 Wu Ai-dong (An hui provincial hospital,Hefei,Anhui, 230061, China);Dosimetry Verification and Quality Assurance of Intensity Modulation Radiation Therapy[J];Anhui Journal of Preventive Medicine;2003-01
2 Li Chen,1,2 Li-Xin Chen,1,2 Hong-Qiang Sun,1,2 Shao-Min Huang,1,2 Wen-Zhao Sun1,2,Xing-Wang Gao3 and Xiao-Wu Deng1,21.State Key Laboratory of Oncology in South China,Guangzhou,Guangdong,510060,P.R.China 2.Department of Radiation Oncology,Cancer Center,Sun Yat-sen University,Guangzhou,Guangdong,510060,P.R.China 3.Department of Radiation Oncology,No.458 Hospital of People's Liberation Army,Guangzhou,Guangdong,510060,P.R.China;Measurements and comparisons for data of small beams of linear accelerators[J];Chinese Journal of Cancer;2009-03
3 LI Jun1,ZHANG Xizhi1,ZHAI Zhenyu2,TAN Fei1,GE Heping1,ZHONG Guifang1 1 Departemt of Radiotherapy,the People's Hospital of Subei,Yangzhou,Jiangsu Province,225001;2 Department of Radiotherapy,Jiangsu Cancer Hospital,Nanjing 210009;Clinical parameters measurement and verification of 3D-TPS for tumour treatment[J];Beijing Biomedical Engineering;2008-05
4 PU Ping,LI De zhi,LI Guang hui,et al. (Cancer Center of PLA,Xinqiao Hospital,the Third Military Medical University,Chongqing 400037,China);Comparison of conventional conformal radiotherapy with conventional radiotherapy in eighty-eight patients with nasopharyngeal carcinoma.[J];Chongqing Medical Journal;2004-07
5 HUANG Ba-qun,YANG Shi-shan,LIU Geng-chun, et al.Department of Radiation Oncology ,Xiantan Affiliated Hospital,Central South University ,Xiantan,411100,China;A Clinical Trial in Improving External Irradiation Technique for Head-neck Neoplasms[J];Journal of Chinese Physician;2003-07
6 YANG Yue-qin 1,ZHU Miao-sheng 2,ZHANG Hong-wei 3 (1. Department of Radiation oncology,the Second Affiliated Hospital,Dalian Medical University,Dalian 116027,China;2.Department of Radiation Oncology,Bei Jing Oncology Hospital,Beijing 100730,China;3;Measurement of important physical performances for Varian 2300 C/D linear accelerator[J];Journal of Dalian Medical University;2000-04
7 YANG Yue-qin 1,CHEN Ying-hai 1,LIU Ya-qi 2 (1.Department of Radiation Oncology,the Second Affiliated Hospital, Dalian Medical University,Dalian 116027,China; 2.Department of instrument,Dalian Medical University,Dalian 116027,China);The effects of depth and field size on wedge factor in the wedge field of oncology radiation[J];Journal of Dalian Medical University;2001-01
8 CHEN Ying-hai,YANG Yue-qin,MA Yu-hong,ZOU Li-juan(Department of Radiation Oncology,the Second Affiliated Hospital of Dalian Medical University,Dalian 116027,China);Verification of accuracy of positions and dose of ~(192)Ir source for China-made HM-HDR brachytherapy machine[J];Journal of Dalian Medical University;2007-06
9 LI De zhi, ZHOU Yi bing, WAN Jiu qing, CHEN Xing hua, CHEN Zheng tang (Center of Cancer of PLA, Xinqiao Hospital, Third Military Medical University, Chongqing 400037, China);Preparation and clinical application of TBI in pretreatment of HSCT[J];Acta Academiae Medicinae Militaris Tertiae;2003-08
10 HONG Wen song, WANG Shun guan, CAI Chang qing (Department of Radiotherapy, Guangdong NO.2 People's Hospital, Guangzhou 510317, China);Analysis and Optimization of MLC Shape in Radiotherapy[J];Journal of Branch Campus of the First Military Medical;2004-01
China Proceedings of conference Full-text Database 10 Hits
1 SHAN Jinlu1,2 , ZHANG Shaoxiang1 , TAN Liwen1, WANG Ge2, WANG Dong2, LEI Xin2 (1. Department of Human Anatomy, Third Military Medical University,Chongqing,400038, China; 2.Cancer center, Daping Hospital and Research Institute of Surgery, Third Military Medical University, Chongqing,400042, China);Research on Digitized Radiotherapy Model of the Pelvic Cavity[A];[C];2008
2 Chen Shao-wen~(1,2) Wang Xue-tao~3 Chen Li-xin~4 Cao Wu-fei~1 Tang Qiang~1 Liu Xiao-wei~1 (1.Physics Department,Zhongshan University,Guangzhou 510275 2.Electron Engineering Department,Dongguan University of technology,Dongguan 523808 3.Guangdong Province Hospital of TCM,Guangzhou 510120 4.Radiotherapy Department of Cancer Center of Zhongshan University,Guangzhou,510060);Evaluation for the Incidence Electron Beam Parameters in Medical Linac[A];[C];2008
3 WU Yi-can~1 LI Guo-li~(1,2) TAO Sheng-xiang~(1,3) WU Ai-dong~(1,4) KONG Ling-ling~5 LIU Bo-xue~6 LIN Da-quan~7 CHEN Yi-xue~1 SONG Gang~1 ZHAO Pan~1 LIN Hui~(1,2) CHEN Chao-bin~1 HUANG Qun-ying~1 WU Li-jun~1 (1.Institute of Plasma Physics,Chinese Academy Science,Hefei Anhui 230031,China;2.Hefei University of Technology;Hefei Anhui 230009,China;3.Artillery Institute of PLA,Hefei Anhui 230031,China;4.Anhui Provincial Hospital,Hefei Anhui 230001,China;5.Anhui Medical University,Hefei Anhui 230022,China;6.Antichemistry Research Institute of China,Beijing 102205,China;);Research and Development of an Accurate/Advanced Radiation Therapy System (ARTS)[A];[C];2008
4 Zheng Zu-an Cheng Yuan Yu Shiying~1 Department of oncology,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan 430030,China;The Evaluation Models on the Relativity between the Field Precision and the Droop Misshaping Induced by the Gravitational Force of the Equipment Table Plate in Radiotherapy[A];[C];2007
5 Chen Shao-wen~(1,2) Wang Xue-tao~3 Chen Li-xin~4 Cao Wu-fei~1 Tang Qiang~1 Liu Xiao-wei~1 (1.Physics Department,Zhongshan University,Guangzhou 510275 2.Electron Engineering Department,Dongguan University of technology,Dongguan 523808 3.Guangdong Province Hospital of TCM,Guangzhou 510120 4.Radiotherapy Department of Cancer Center of Zhongshan University,Guangzhou,510060);Evaluation for the Incidence Electron Beam Parameters in Medical Linac[A];[C];2008
6 QIU Xuejun SHI Rong ZHOU Chunwu ZHAO Xinming (Beijing Daheng Medical Equipment Co.,Ltd.,CAS,Beijing 100080,China) (Tumor Hospital of Chinese Academy of Medical Science,Beijing 100021,China);Research on Three Dimensional Digitally Reconstructed Radiograph Based on CT Images[A];[C];2007
7 ;EXPERIENCES OF DESIGNING 3D INTENSITY MODULATED ONFORMAL RADIATION THERAPY’S LANNING[A];[C];2008
8 Ningbo No.2 Hospital(315010) Wang Xun Wang Yue-li;Application and function evaluation of Daily QA3 in quality assurance of radiation oncology physics[A];[C];2009
9 Jiang Ruiyao,Wang Yibing,Li Bin Shanghai 6th People's Hospital affiliated to Shanghai Jiaotong University 200233;Safety Measurement Analysis and Quality Assurance of the Output Stability of Medical Linear Accelerator[A];[C];2010
10 YU Hui ZHANG Shu-xu SHEN Guo-hui TAN Jian-ming WANG Shi-qin (Department of Radiotherapy Center,the Affiliated Tumour Hospital of Guangzhou Medical College,Guangzhou 510515,P.R.China);The Application Features of VARIS Registration Software in Radiotherapy Positioning Verification[A];[C];2010
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 QI Zhen-Yu1,2, HUANG Shao-Min1,2, DENG Xiao-Wu1,21. State Key Laboratory ofOncology in Southern China,Guangzhou, Guangdong, 510060,P. R. China2. Department of RadiationOncology,Cancer Center,Sun Yat-sen University,Guangzhou, Guangdong, 510060,P. R. China;Calibration of CT Values Used for Radiation Treatment Planning and Its Impact Factors[J];Chinese Journal of Cancer;2006-01
2 SUN Chao-yang,XIAO Feng,SHI Mei,WEI Li-chun,LU Jun(1.Dept of Radiation Oncology,Xijing Hospital,Fourth Military Medical University,Xi'an Shanxi 710032,China);Routine Measurement Method and Quality Assurance Procedure on Varian Multi-leaf Collimator[J];Chinese Journal of Medical Physics;2005-06
3 LI Long-gen,XU Zhi-yong,FU Xiao-long,SONG Liang,CHEN Xiao-hua(Department of Radiation Oncology,Fudan University Cancer Hospital,Shanghai 200032,China);Design and Application of a Quality Control System for a Network of Radiotherapy[J];Chinese Journal of Medical Physics;2007-01
4 <author>ang Chun-guang, CEN He-qing, QI Zhen-yu, et al. Cancer Center of Sun Yat - sen University, Guangzhou 510060 China;<title>utine quality assurance and quality control procedure for conventional x - ray simulator[J];China Medical Equipment;2004-01
5 ;Establishment and Practice of Quality Assurance in the Radiotherapy[J];China Medical Equipment;2005-03
6 ZHU Yuan *, DI Xiaoyun, MA Shenglin, ZHENG Zhongnan. *Department of Radiation Oncology, Zhejiang Cancer Hospital, Hangzhou 310022, China;Pilot study on radiotherapy quality control and quality assurance in Zhejiang province[J];Chinese Journal of Radiation Oncology;2002-03
7 MA Jin-li, JIANG Guo-liang, FU Xiao-long, LIAO Yuan, WU Kai-liang, ZHOU Li-jun. Department of Radiation Oncology, Cancer Hospital, Fudan University, Shanghai 200032, China;Quality assurance for multileaf collimator with radiographic film exposed by slit beam[J];Chinese Journal of Radiation Oncology;2004-02
8 HUANG Xiao-yan HUANG Shao-min ZHANG Li DENG Xiao-wu ZHONG Ning-shan CHEN Li-xin Department of Radiation Oncology,Cancer Center,Sun Yat-sen University,Guangzhou 510060,China;Dosimetric verification of a commercial three-dimension treatment planning system[J];Chinese Journal of Radiation Oncology;2006-06
9 LIN Cheng-guang~* LI Guo-wen LIN Lui-wen LI Wen-jie HUANG Jun SU Jian-xin DEN Xiao-wu CUI Nian-ji ~*Department of Radiation Therapy,Cancer Center,Sun Yat-sen University,Guangzhou 510060,China;Set-up uncertainties with radiation therapy for nasopharyngeal carcinoma[J];Chinese Journal of Radiation Oncology;2006-06
10 YU Jin-ming,YU Yong-hua;Quality Assurance and Quality Control in Radiotherapy[J];Bulletin of Chinese Cancer;2004-08
【Secondary References】
Chinese Journal Full-text Database 5 Hits
1 HU Nan,ZHENG Xiao-lin,LUO Hong-yan(Bioengineering College,Chongqing University,Chongqing 400044,China);Application of optical targeting and tracking in modern radiotherapy[J];Laser Journal;2010-02
2 CHEN Zhi-jian;Quality Control of Radiotherapy——an Eternal Topic[J];China Cancer;2010-08
3 LIN Cheng-guang, ZHANG Hua-man, WU Jian-hua, et al.(Sun Yat-sen University Cancer Center, Guangzhou 510060, China);An Analysis on Irradiation Error in the Implementation Process of Radiotherapy[J];China Cancer;2010-08
4 LIU Peng,YU Wei-hai, XIAO Kai-min Equipment Department, Qingdao Haici Medical Group,Qingdao Shandong 266000,China;Quality Assurance and Quality Control of Medical Linear Accelerator[J];China Medical Devices;2010-09
5 XU Zi-hai1,MO Li1,LIU Lin-xiang2,LIU Ya-qin2(1.Radiotherapy Center of No.303 Hospital of PLA,Nanning 530021,China; 2.Southern Medical University,Guangzhou 510515,China);Siemens MLC and Its Quality Guarantee[J];Chinese Medical Equipment Journal;2011-01
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved