Full-Text Search:
Home|Journal Papers|About CNKI|User Service|FAQ|Contact Us|中文
《Chinese Journal of Reparative and Reconstructive Surgery》 2008-08
Add to Favorite Get Latest Update

MAJOR INFLUENTIAL FACTORS OF THE MICTURITION ALERT DEVICE DEDICATED TO NEUROGENIC BLADDERS

WANG Jianhuo, HOU Chunlin, ZHENG Xianyou, XU Zhen, WANG Wanhong, LIN Haodong. Department of Orthopaedics, Changzheng Hospital, the Second Military Medical University, Shanghai, 200003, P.R.China.  
Objective To study major influential factors of the micturition alert device dedicated to neurogenic bladders for the product design and clinical application of the device. Methods One ferrite permanent magnet with thickness and diameter of 3 mm and 10 mm, respectively, and three NdFeB permanent magnets with the thickness of 3 mm and diameter of 10, 15 and 20 mm, respectively, were used. The effects of thickness of the abdominal wall as well as the position and type of permanent magnets on the micturition alert device dedicated to neurogenic bladders were measured in vitro simulated test, when the abdominal wall was set to 2, 3, 4, 5, 6, 7, 8 and 9 cm, respectively, and the position of permanent magnets was 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11 and 12 cm, respectively. The effect of the geomagnetic field on the device was measured under the condition that the thickness of the simulated abdominal wall was set to 2, 3, 4 and 5 cm, respectively, and the position of permanent magnets was 2, 3, 4, 5, 6, 7, 8, 9 and 10 cm, respectively. Results The value showed in the warning unit was positively correlated with the position of the ferrite permanent magnet only when the thickness of the simulated abdominal wall was 2 cm (r=0.632, P 0.05). The correlation between the value of the warning unit and the position of NdFeB permanent magnets was significant (r 0.622, P 0.05), which was intensified with the increasing diameter of NdFeB permanent magnets, but weakened with the increasing thickness of the simulated abdominal wall. The effect of the geomagnetic field was correlated with the exposition of the body, the position of the permanent magnet and the thickness of the abdominal wall. Conclusion The major influential factors of the micturition alert device dedicated to neurogenic bladder include the magnetism and location of the permanent magnet, the thickness of the abdominal wall and the geomagnetic field. These factors are correlated with and affect each other. Reasonable allocation of these factors may optimize the device.
【Key Words】: Neurogenic bladder Bladder volume monitor Micturition alert device Geomagnetic field Spinal cord injury
【Fund】: 国家自然科学基金资助项目(30772217)~~
【CateGory Index】: R197.39
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 1 Hits
1 WANG Jian-huo1,HOU Chun-lin2,Wei Chun-qin3 1.The Third Department of Orthopaedics,The First Affiliated Hospital of Fuzhou General Hospital of Nanjing Military Area Command,Putian,Fujian 351100;2.Department of Orthopaedics,Changzheng Hospital,Second Military Medical University;3.Department of Ultrasound,Changzheng Hospital,Second Military Medical University,Shanghai 200003,China;Investigation of the lower abdominal wall thickness in adult and its significance for the micturition alert device on the principle of a compass[J];Chinese Journal of Clinical Anatomy;2011-04
【Citations】
Chinese Journal Full-text Database 8 Hits
1 WANG Junhong1,2,MA Yanwei1(1 Applied Superconductivity Laboratory,Institute of Electrical Engineering,Chinese Academy of Sciences,Beijing 100080; 2 Graduate University of Chinese Academy of Sciences,Beijing 100080);Research Progress in Magnetic Polymer Matrix Nanocomposites[J];Materials Review;2007-07
2 YAN Deng-jun1,Li Wei1,WANG Gui-qin2,ZHAO Ji-wan2(1.Electrical Engineering Department,Hohai University,Nanjing 210098,China;2.Physics Department,Nanjing University,Nanjing 210008,China);Progress in Bio-Electromagnetism Research[J];Journal of Electrical & Electronic Education;2007-03
3 WANG Jun-Xue, LUO Er-Ping, SHEN Guang-Hao, XIE Kang-Ning, WU Xiao-MingDepartment of Military Medical Equipment & Metrology, School of Biomedical Engineering, Fourth Military Medical University, Xi'an 710033, China;Clinical effect of constant magnetic field on postoperative wound healing[J];Journal of the Fourth Military Medical University;2006-08
4 GUO Run-xia.Institute for Environmental Health and Related Products Safety,Chinese Centers for Disease Control and Prevention,Beijing100021,China;Biological Effects of Constant Magnetic Field and Its Safety Exposure Limits[J];Journal of Environment and Health;2003-01
5 ZHU JieBiophysics Lab, College of Physics and Information Technology, Shanxi Normal University, Xi'an 710062 China;Study on the Biological effects of Magnetic Fields and Its Possible Mechanisms[J];Biomagnetism;2005-01
6 DU You-Wei(Jiangsu Provincial Laboratory for Nano Technology and National Laboratory of Solid State Microstructures Nanjing University,Nanjing 210093,China);Development of magnetic materials in recent years[J];Physics;2006-09
7 Zhang Yu, Zhang Xiao-yun School of Life Sciences, Shenzhen University, Shenzhen 518060, Guangdong Province, China;Acute toxicity effects of 4T superconductive static magnetic field in rats[J];Chinese Journal of Clinical Rehabilitation;2006-01
8 Lü Jian-qiang Han Xing-hai Xu Mei-juan Zhao Dong-bao Department of Rheumatology and Immunology Changhai Hospital Second Military Medical University of Chinese PLA Shanghai 200433 China;Measurement of magnetic field distribution and expression of dosage in magnetic treatment[J];Chinese Journal of Clinical Rehabilitation;2006-29
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 LU Jia-xuan et al (College of Electrical Engineering,Guizhou University,Guiyang,Guizhou 550003);Magnetic Effect of Microbes and Its Application in Environment[J];Journal of Anhui Agricultural Sciences;2007-13
2 XU Zhong-chuan et al(Department of Biological Science and Food Engineering,Changshu Institute of Technology,Changshu,Jiangsu 215500);Study on the Biological Effect of Magnetic Field on Growth of Lindera aggregata (Sims) kosterm Plantlet in vitro[J];Journal of Anhui Agricultural Sciences;2008-23
3 XU Zhong-chuan et al(Department of Biology and Food Engineering;Changshu Institute of Technology,Changshu,Jiangsu 215500);Study on the Biological Effects of Magnetic Treatment on the Growth of Edible Fungi Mycelia[J];Journal of Anhui Agricultural Sciences;2009-07
4 LI Xue1,2,ZHANG Junxi1,2,LIU Guoping3,YAN Licheng4(1 Key Laboratory of State Power Corporation of China,Electrochemical Research Group,Shanghai University of Electric Power,Shanghai 200090;2 School of Environmental and Chemical Engineering,Shanghai University,Shanghai 200072;3 Shanghai Bao Steel Tiantong Magnetic Materials Co.Ltd,Shanghai 201900;4 Hangzhou Teachers College,Hangzhou 310036);Research on Structure and Properties of Mn-Zn Ferrite and Its Development[J];Materials Review;2008-08
5 WEI Lei1,YANG Qiaozhen1,YANG Lan2,SUN Kai2,ZHAO Yongxiang1(1 School of Chemistry and Chemical Engineering,Shanxi University,Taiyuan 030006;2 State Key Laboratory of ChemicalResource Engineering,Beijing University of Chemical Technology,Beijing 100029);Preparation and Properties of the Co_(1-x)Zn_xFe_2O_4 Ferrite Aerogels[J];Materials Review;2010-22
6 XU Zhong-chuan,JI Hong,YUAN Wen-qin (School of Biology and Food Engineering,Changshu Institute of Technology,Changshu 215500,China);Biological Effects of Magnetic Field on the Growth of Flammulina velutipes(Cart.)Sing Mycelia[J];Journal of Changshu Institute of Technology;2010-02
7 ZHU Jie1, ZHANG Yin-jing2 1. College of Physics and Information Technology, Shaanxi Normal University, Xi’an 710062, China; 2. Department of Mechanical and Electrical Engineering, Henan Textile College, Zhengzhou 450007, China;Biological Effects of Different Kinds of Magnetic Fields on Tumors[J];Journal of Magnetic Materials and Devices;2005-04
8 WANG Jian-huo1,LI Mei-jun2,LEI Jun2,HOU Chun-lin3 1.The First Surgical Department,The 476th Clinical Division,Fuzhou General Hospital,PLA Nanjing Military Area Command,Fuzhou 350002,Fujian,China2.Department of Pathology,The 476th Clinical Division,Fuzhou General Hospital,PLA Nanjing Military Area Command,Fuzhou 350002,Fujian,China3.Department of Orthopaedics,Changzheng Hospital,Second Military Medical University,Shanghai 200003,China;Evaluation of biological safety of silicon membrane embedded permanent magnets implanted in canine[J];Academic Journal of Second Military Medical University;2010-03
9 YAN Deng-jun1,Li Wei1,WANG Gui-qin2,ZHAO Ji-wan2(1.Electrical Engineering Department,Hohai University,Nanjing 210098,China;2.Physics Department,Nanjing University,Nanjing 210008,China);Progress in Bio-Electromagnetism Research[J];Journal of Electrical & Electronic Education;2007-03
10 Lv Yi,LI Jian-Hui,LIU Chang,SHI Yuan,ZHANG Zhi-Yong,WANG Bo,YU Liang Department of Hepatobiliary Surgery,First Affiliated Hospital,Medical School,Xi'an Jiaotong University,Xi'an 710061,China;Development of sutureless magnetic bilioenteric anastomosis stents and its primary application in repairing acute bile duct injury in dogs[J];Journal of the Fourth Military Medical University;2007-17
China Proceedings of conference Full-text Database 1 Hits
1 LI Liang-chao~*,LIANG Xiao-xi,LIU Hui,CHEN Ke-yu,HAO Bin (College of Chemistry and Life Science,Institute of Physical Chemistry,Zhejiang Normal University, Jinhua 321004);Synthesis and absorbing wave performance of Ba_(1-x)La_xFe_(10)Al_2O_(19) ferrites[A];[C];2010
【Co-references】
Chinese Journal Full-text Database 1 Hits
1 WANG Jianhuo, HOU Chunlin, ZHANG Wei, ZHENG Xianyou, XU Zhen, WANG Wanhong, LIN Haodong. Department of Orthopedic Surgery, Changzheng Hospital, the Second Military Medical University, Shanghai, 200003, P.R.China.;MICTURITION ALERT DEVICE DEDICATED TO NEUROGENIC BLADDERS[J];Chinese Journal of Reparative and Reconstructive Surgery;2008-05
【Secondary References】
Chinese Journal Full-text Database 1 Hits
1 DONG Hai-jing;LIU Zhi-mei;LI Hua-wei;;Nursing care of permanent cystostomy patients with multifunctional bladder fistula[J];Chinese Journal of Nursing;2014-06
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 Qiao Qingli, Wang Mingshi, Tian Xin  (Depart of BME, College of Precision Instruments & Optoelectronics Tianjin University, Tianjin\ 300072) (Depart. of BME, Tianjin Medical University, Tianjin 300072);Modelling and 3D Analysis of its Induced Electric Field of Magnetic Stimulation of Excitable Tissue of Human Body[J];BEIJING BIOMEDICAL ENGINEERING;2000-03
2 Zhang Junyi, Lu Xialing, Liu Jimin, Xie Jiangli, Chu Huiming, Fu Yan (Dept. of Physics, Dept. of Biochemistry);The Effects of magnetic fields on the activity of serum superoxide dismutases in mice[J];;1993-06
3 YANG Feng yu 1, LI Yi ning 2, LIU Xin rong 3, CONG Li 4 1. Gansu University of Technology, Lanzhou 730050, China; 2. Gansu Province Women's and Children's Health Care Hospital, Lanzhou 730060, China; 3. Gansu Province Cancer Research Institut;Experiment and Analysis on Restraining Solid Tumorin Mouse by Magnetic Field[J];Journal of Magnetic Materials and Deuices;2001-04
4 WANG Hai-bin NIU Zhong-qi(School of Electronic Engineering, Xidian University, Xi′an Shaanxi 710071, China );Specific absorption and currents induced in human body for exposure to electromagnetic pulses[J];Chinese Journal of Radio Science;2006-02
5 FANG Wei, LIANG Guang-hua, WANG Jia-gang;The Discussion on Body Endanger of Electromagnetic Radiation[J];Electric Machine & Electric Apparatus Technologres;2004-04
6 WANG Jun-Xue, LUO Er-Ping, SHEN Guang-Hao, XIE Kang-Ning, WU Xiao-MingDepartment of Military Medical Equipment & Metrology, School of Biomedical Engineering, Fourth Military Medical University, Xi'an 710033, China;Clinical effect of constant magnetic field on postoperative wound healing[J];Journal of the Fourth Military Medical University;2006-08
7 ZHAO Rui,ZHOU Hui-ying,CHU Qiu,et al(Department of Biochemistry,School of Basic Medical Sciences,Beihua University,Jilin 132001,China);The influence of magnetic field on ATP、cAMP and cGMP of big rats with AMI[J];Chinese Journal of Control of Endemic Diseases;2006-03
8 SHA Zong IEEE Fellow;The Influence Of Electromagnetic Radiation On The Human Body[J];Electronics Quality;2003-03
9 TAO Gui-sheng , XIA Ling , HE Chao-ming . Department of Biomedical Engineering , Zhejiang University, Hangzhou 310027, China;Simulation study of heart stimulation caused by MRI electromagnetic field[J];Foreign Medical Biomedical Engineering Fascicle;2005-01
10 Ma Haizhen;Wu Guoqing(Taiyuan University of Technology,030024);THE STUDY OF EFFECT OF MAGNETIC FIELD ON DEHYDROGENASE OF IMMOBILIZED CELL OF PURPLE NONSULFUR PHOTOSYTHETIC BACTERIA[J];ACTA SCIENTIAE CIRCUMSTANTIAE;1995-03
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved