Quality Control and Quality Assurance for the Isocentre of the Medical Linear Accelerator

HU Jie TAO Jian-min SUN Guang-rong Department of Radiotherapy,Shanghai Tenth People's Hospital,Shanghai,200072  
This article expounds the method of quality control and quality assurance for the isocenter of the medical linear accelerator and explains the content and standards of its regular examinations,in order to ensure the safety and efficiency in use.
【CateGory Index】: R812
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 10 Hits
1 JIN Sun-jun;WANG Kun;SONG Ming-zhe;HUANG Ji;FAN Yao-dong;HUANG Jin-feng;YANG Xiao-yuan;CHANG Xue;ZHANG Jian;National Institute of Metrology;China Institute of Atomic Energy;Beijing Information Science and Technology University;Shenyang Metrology Testing Institution;;Study for the Isocenter Property of the Clinical Accelerator via a Dosimetric Experiment[J];核电子学与探测技术;2015-09
2 ZHANG Xiang;FAN Wengang;SHI Shaohua;YE Peiqing;ZHANG Hui;Beijing Key Laboratory of Precision/Ultra-Precision Manufacturing Equipments and Control,State Key Laboratory of Tribology,Institute of Manufacture Engineering,Department of Mechanical Engineering,Tsinghua University;;Average vector method for determining isocenter of rotated radiotherapy equipment[J];清华大学学报(自然科学版);2015-07
3 ZHOU Jun;Radiation Oncology Center of Sichuan Provincial Corps Hospital CAPF;;Using Visi-X to adjust Isocenter of Medical Linear Accelerator[J];医疗装备;2014-09
4 Yu De-quan,Qu Huan-min,Shao Qiu-ju,Liang Jun,Gao Hong,(Department of Radiotherapy,Tang Du Hospital,The Fourth Military Medical University,Xi'an Shanxi 710038,China);Electron Portal Image Device in Accelerator Radiation Field Application in The Measurement of The Discussed[J];中国医学物理学杂志;2013-02
5 WANG Jiea,ZHANG Yu-haia,WANG Kanga,ZHAO Jiana, LIU Ya-junb a.Department of Radiotherapy;b.Medical Engineering Department,The 309th Hospital of PLA,Beijing 100091,China;Maintenance and Treatment Safety of Medical Linear Accelerator[J];中国医疗设备;2012-06
6 CHEN Yong-dong Radiotherapy Center,Yangzhou Hongquan Hospital,Yangzhou Jiangsu 225200,China;Discussion on the Quality Assurance in Dose Calibration of Linear Accelerator[J];中国医疗设备;2012-06
7 YU De-quan,GAO Hong,SHAO Qiu-jiu,LIANG Yun,ZHANG Xin(Department of Radiotherapy,Tang Du Hospital,The Fourth Military Medical University,Xi'an Shannxi 710038,China);Application and Research of Two-dimensional Ion Chamber Array in Daily Quality Assurance of Accelerator[J];中国医学物理学杂志;2010-04
8 XU Feng,SI Jun,WANG Jun-hai,ZHANG Ke(Taian Tumor Hospital,Taian Shandong 271000,China);Development of the Digital Mechanical Isocenter Measuring Instrument[J];中国医疗设备;2010-03
9 Hu Jie,Tao Jianmin,Sun Guangrong,Zhang Ying,Zhang Ying Department of Radiotherapy,ShangHai Tenth People’s Hospital,Shanghai,200072;The Summa of Fourteen Years Usage for a Medical Linear Accelerator[J];中国医疗器械杂志;2010-01
10 PENG Shun-yin (Equipment Department,Huai'an No.1 Hospital Affiliated to Nanjing Medical University,Huai'an Jiangsu 223300,China);Discussion about Manual Adjustment Methods of MLC in Siemens Primus Oncor Linear Accelerator[J];中国医疗设备;2010-01
【Citations】
Chinese Journal Full-text Database 2 Hits
1 Huang Jia-hua Shanghai Municipal Drug and Medical Device Appraisement Center;Isocenter Rotation Resolution Analysis and Technique of Radiotherapy Equipment[J];上海生物医学工程;2003-01
2 Dai Jianrong, Hu Yimin. Cancer Hospital ,CAMS, Beijing 100021;The Precision and Accuracy Analysis of Target Position in X Ray Stereotactic Radiotherapy[J];中华放射肿瘤学杂志;1996-02
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 ZHANG Xiang;FAN Wengang;SHI Shaohua;YE Peiqing;ZHANG Hui;Beijing Key Laboratory of Precision/Ultra-Precision Manufacturing Equipments and Control,State Key Laboratory of Tribology,Institute of Manufacture Engineering,Department of Mechanical Engineering,Tsinghua University;;Average vector method for determining isocenter of rotated radiotherapy equipment[J];清华大学学报(自然科学版);2015-07
2 ZHOU Jun;Radiation Oncology Center of Sichuan Provincial Corps Hospital CAPF;;Using Visi-X to adjust Isocenter of Medical Linear Accelerator[J];医疗装备;2014-09
3 ZHANG Li1,DAI Jing2, CAI Wei-xun2,WEN Zhi-xiang2 1.Radiology Oncology Department,The PLA 458 Hospital,Guangzhou Guangdong 510602,China;2.Radiation Oncology Department,Sun Yat-sen University Cancer,Guangzhou Guangdong 510060,China;A Study on Prevention of Isocenter Treatment Bed Collision[J];中国医疗设备;2012-02
4 CHEN De-lu(Chinese Medicine Hospital in Liaocheng City Radiotherapy Centre,Liaocheng Shandong 252000,China);The Research on the Positioning Error of Head and Neck Precise Location and Positioning Instrument[J];中国医学物理学杂志;2010-05
5 CHEN De-lu(Chinese Medicine Hospital in Liaocheng City Radiotherapy Centre,Liaocheng Shandong 252000,China);Thoracoabdominal Tumor Radiotherapy Positioning and Positioning of Research and Improvement[J];中国医学物理学杂志;2010-04
6 XU Feng,SI Jun,WANG Jun-hai,ZHANG Ke(Taian Tumor Hospital,Taian Shandong 271000,China);Development of the Digital Mechanical Isocenter Measuring Instrument[J];中国医疗设备;2010-03
7 GAO Hong,ZHANG Xin,YU De-quan,LIANG Jun,YAO Hong-jun,WANG Yang,WU Shu-juan (Tangdu Hospital,the Fourth Military Medical University,Xi'an 710038,China);Discussion and Research for Standardization in the Technical Management of Radio-Therapy[J];医疗卫生装备;2009-08
8 YU De-quan, GAO Hong, SHAO Qiu-ju, ZHANG Xi (Tangdu Hospital of the 4th Military Medical University, Xi'an 710038, China);Comparison Between Varian Localization System and Tosplane Localization System[J];医疗卫生装备;2009-01
9 HU Jie TAO Jian-min SUN Guang-rong Department of Radiotherapy,Shanghai Tenth People's Hospital,Shanghai,200072;Quality Control and Quality Assurance for the Isocentre of the Medical Linear Accelerator[J];中国医疗器械杂志;2007-03
10 WU Bing,LI Li,YU Li(People's Hospital of Wuhan University,Wuhan 430060,China);Quality assurance of stereotactic radiotherapy in head and neck cancer[J];医疗卫生装备;2006-07
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 ;EPID在盆腔肿瘤放疗中的摆位误差分析[J];当代医学;2012-02
2 WANG Zhen-jun1,2, WANG Yan1,LIU Zhi-cheng1 1.Biomedical Engineering Institute,Capital Medical University,Beijing 100069,China;2.Biomedical Engineering Department,First Affiliated Hospital of Hebei Northern Institute,Zhangjiakou,Hebei 075000,China;Tentative Research on Quality Control of Medical Linear Accelerator Using Root Cause Analysis[J];中国医疗设备;2011-10
3 Zhang Guofeng,Tang Yan,Sa Ying,Ma Aifang Department of Hematology and Oncology,Karamay Centre Hospital,Karamay Xinjiang 834000,China;Daily Quality Assurance of Linac Radiation Field[J];中国医疗器械杂志;2011-05
4 LIU Peng,YU Wei-hai, XIAO Kai-min Equipment Department, Qingdao Haici Medical Group,Qingdao Shandong 266000,China;Quality Assurance and Quality Control of Medical Linear Accelerator[J];中国医疗设备;2010-09
5 ZENG Zi-li (Department of Tumor, Liutie Central Hospital, Liuzhou 545007, Guangxi Province, China);Quality Assurance and Quality Control of Medical Electron Linear Accelerator[J];医疗卫生装备;2010-09
6 YU De-quan,GAO Hong,SHAO Qiu-jiu,LIANG Yun,ZHANG Xin(Department of Radiotherapy,Tang Du Hospital,The Fourth Military Medical University,Xi'an Shannxi 710038,China);Application and Research of Two-dimensional Ion Chamber Array in Daily Quality Assurance of Accelerator[J];中国医学物理学杂志;2010-04
7 YU Da-hai,LIU Ling,REN Hong-rong,GUAN LuanDepartment of Radiation Oncology of Xuzhou Central Hospital,Xuzhou 221009,P.R.China;Clinical research of setup optimization in radiotherapy by EPID[J];中华肿瘤防治杂志;2010-06
8 YU Chang-hua, HAN Ji-hua, ZHU Zhen-ya, ZHANG Xiao-ye, ZHU Wei-guo, LI Tao (Department of Radiation Oncology, First People's Hospital of Huaian, Nanjing Medical University, Huaian Jiangsu 223300, China);EPID for Set-up Errors Analysis and Quality Assurance of Radiotherapy in Head and Neck Cancer[J];中国医学物理学杂志;2009-03
9 YANG Xiao-guang, HE Qiang, LI Peng-wu (College of Public Health, Ji lin University, Changchun Ji lin 130021, China);Test and Analysis on the Performance of GK-6MeV Medical Electron Linear Accelerator[J];中国医疗设备;2009-01
10 YANG Shao-zhou,WANG Sheng-jun(Medical Equipment Department of Nanfang Hospital,Guangzhou Guangdong 510515,China);Methods for Verifying and Adjusting the Mechanical Isocenter of Varian Accelerators[J];中国医疗设备;2008-09
【Secondary References】
Chinese Journal Full-text Database 10 Hits
1 MA Yan;Shandong Yantai Yantai Mountain Hospital Equipment;;Medical Linear Accelerator Radiation Safety and Occupational Safety Management of the Implementation of the Thinking Path[J];中国卫生产业;2015-20
2 WANG Xue-tao;ZHU Lin;DAI Zhen-hui;ZHAO Shi-wu;YANG Geng;ZHU Yuan-hu;Radiotherapy Center of University Town Branch, Guangdong Provincial Hospital of TCM;;Investigation on dose characteristics of 2D array MatriXX[J];医疗卫生装备;2015-06
3 QIU Yun-feng;Department of Equipment, Hai'an Tumour Hospital;;Working Principle and Troubleshooting of the Magnetron of Elekta Precise Accelerator[J];中国医疗设备;2015-05
4 ZHANG Bing-chang;SONG Qiang;Department of Medical Equipment,Qingdao Municipal Hospital;;Working Principle and Maintenance of the MLC System of Varian Linear Accelerator[J];中国医疗设备;2015-03
5 HUANG Bao-tian;Department of Radiation Oncology,Cancer Hospital of Shantou University Medical College;;Performance test and quality assurance of Truebeam~(TM)[J];中国医学装备;2015-01
6 FU Hong-jie;Department of Radiotherapy 1st Hospital of Xinxiang;;Measurement analysis of the dose output stability of NMSR600 medical linear accelerator[J];中国医学装备;2014-12
7 LI Lu-jun;LI Zhi-cong;ZHU Hong-zheng;YU Hai-kun;ZHOU Qing-hua;Department of Radiation Oncology, Wuzhou Red Cross Hospital;;Replace and Quality Assurance of Accelerating Tube of VARIAN UNIQUE Linear Accelerator[J];中国医疗设备;2014-10
8 ZHANG Hai-cheng;Department of Medical Engineering, People' Hospital, DaXing District;;Research on the principle and application of high voltage of the Elekta accelerator[J];中国医学装备;2014-09
9 LI Xian-fu;XIE Li;GUO Fei;YANG Hua-dong;ZHOU Jin-wei;MA Dai-yuan;LIU Mi;TAN Bang-xian;Medical Imaging Sichuan Province Key Laborary,Department of Radiotherapy;Affiliated Hospital of North Sichuan Medical College;;Study on Rapid Maintenance of Elekta Precise Linear Accelerator[J];中国医学物理学杂志;2014-04
10 LI Jing;ZHANG Jin-jian;WEN Ting;LI Zhi-qiang;HOU You-xian;JIA Jun-song;ZHONG Yu;CHEN Jing;WANG Yan;XU Yan-hong;Center for Helical Tomotherapy,Guangzhou General Hospital of Guangzhou Military Area Command;;Failures and reasons analyses of helical tomotherapy system[J];医疗卫生装备;2014-06
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved