Comparative study of ultrasonic elastography and conventional ultrasonography in differential diagnosis of breast lesions

SHEN Jian-hong1, LUO Bao-ming2, OU Bing2, YANG Hai-yun2(1.Department of Imaging, Second Affiliated Hospital, Guangzhou University of TCM, Guangzhou 510120, China;2.Department of Ultrasound, Second Affiliated Hospital, Sun Yat-sen University, Guangzhou 510120, China)  
Objective To compare the value of conventional ultrasonography (US, including gray-scale ultrasonography, color Doppler flow imaging and Doppler spectrum) and ultrasonic elastography (UE) in differentiating the benign and malignant breast lesions. Methods The static sonograms of US and UE of the 475 breast lesions which pathologically proved were reviewed. Receiver operating characteristic (ROC) curves were used to assess the diagnostic value of UE and US. Results The areas under the ROC curve (Az) of the two modalities were 0.959(UE) and 0.899(US), respectively. The difference between them was significant. Conclusion UE surpassed US in regard of the comprehensive diagnostic value for differentiating benign and malignant breast lesions.
【CateGory Index】: R445.1
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 4 Hits
1 LUO Bao-ming,OU Bing,ZHI Hui Department of Ultrasound,the Second Affiliated Hospital,Sun Yat-sen University,Guangzhou 510120,China;Factors Affecting the Performance of Ultrasonic Elastography in Breast Tumors and Its Solutions[J];Acta Academiae Medicinae Sinicae;2008-01
2 MA Qi1,FANG Jun-chu1,SHAN Yu-xi2,YANG Dong-rong2 (1.Center of Ultrasound,2.Department of Urology,the Second Affiliated Hospital of Soochow University,Suzhou 215004,China);Transrectal real-time elastography in normal prostate and benign prostatic hyperplasia[J];Chinese Journal of Medical Imaging Technology;2010-03
3 SHEN Wen,DING Hong,WANG Wen-ping,LI Cong,LI Na,XU Zhi-zhang (Department of Ultrasound,Zhongshan Hospital of Fudan University,Shanghai 200032,China);Establishment of reference value of liver virtual touch tissues quantification values in healthy people[J];Chinese Journal of Medical Imaging Technology;2010-04
4 WANG Xiao-hua,XUE Nian-yu,WANG Liang,LIN Yi-yiDepartment of Ultrasound,The Second Affiliated Hospital of Wenzhou Medical College,Wenzhou,Zhejiang 325027,P.R.China;The value of two-dimensional ultrasonography combined with elastography in the diagnosis of thyroid cancer[J];Journal of Medical Imaging;2010-05
【Citations】
Chinese Journal Full-text Database 3 Hits
1 Luo Baoming,Ou Bing,Feng Xia,et al Dept.Ultrasound in Medicine,Second Affiliated Hospital,Sun Yat-sen University,Guangzhou 510120 China;Breast Diseases:Comparative Study of Real-Time Tissue El astography with Pathology[J];Chinese Journal of Ultrasound In Medicine;2005-09
2 WANG Yi~(1*),WANG Yong~1,ZHANG Xi-min~1,QIN Qian-miao~1,WANG Yi-da~1,XU Zhi-zhang~2 (1.Department of Ultrasound,Huashan Hospital,Fudan University,Shanghai 200040,China;2.Medical Ultrasound and Engineering Institute of Fudan University,Shanghai 200032,China);Evaluation of elastography application in differentiating benign and malignant breast tumors[J];Chinese Journal of Medical Imaging Technology;2005-11
3 ZENG Wei,ZHU Shiliang,HUANG Yafang. (Department of Ultrasound,Shanghai Cancer Hospital,Fudan University,200032);High frequency color doppler ultrasound diagnosis of malignant breast tumor[J];Tumor;2002-04
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 XIONG Ai-min,CAI Wei-xin,CHEN Yi-ke,FANG Su-fang(Department of Ultrasonography,the 85th Hospital of PLA,Shanghai 200052,China);Comparing the diagnostic value of color Dopplor ultrasonography and mammography in breast tumor[J];Journal of Southeast China National Defence Medical Science;2007-03
2 ZHUANG Chengcheng,XIAO Ying(Department of Ultrasound,Xiangya Hospital,Central South University,Changsha 410008,China);Ultrasonic elastography and molybdenum X-ray photography in differential diagnosis of breast diseases[J];Journal of Central South University(Medical Sciences);2009-01
3 SHEN De-juan reviewing,YANG Bin checking(Department of Ultrasound,Nanjing General Hospital of Nanjing Military Command,PLA,School of Medicine,Nanjing Uiniversity,Nanjing 210002,Jiangsu,China);Prospect and diagnosis of sonography in breast cancers[J];Journal of Medical Postgraduates;2007-02
4 Yuan Ying, Gong Weibing, Zhang Shouhua, Sun Yu, Wang QianDeparment of Ultrasound,Nanfang Hospital,Nanfang Medical Univevsity,Guangzhou 510515, China;Primary study on the diagnostic value of elastic imaging on partial cholestatic hepatic fibrosis in rats[J];Journal of Ultrasound in Clinical Medicine;2007-06
5 WANG Shiguang,YUE Linxian Department of ultrasound,Pepole's Hospital of Sichuan Province,Chengdu 610072, China;The application value of elastosonography in the diagnosis of thyroid nodules[J];Journal of Ultrasound in Clinical Medicine;2008-11
6 SHEN Jianhong1, LUO Baoming2, OU Bing2, et al 1.Department of Imaging, The Second Affiliated Hospital, Guangzhou University of TCM, Guangzhou 510120; 2.Department of Ultrasound in Medicine, The Second Affiliated Hospital, Sun Yat-sen University, Guangzhou 510120 Corresponding author: Luo Baoming;The value of ultrasonic elastography for differentiating malignant and benign mass of breast[J];Lingnan Modern Clinics in Surgery;2006-05
7 FENG Xia, LUO Bao-ming, OU Bing, YANG Hai-yun, WEN Yan-ling, ZHI Hui (Department of Ultrasound, Second Affiliated Hospital, Sun Yat-sen University, Guangzhou 510120, China);Evaluation elastic score's usefulness in the diagnosis of benign and malignant breast diseases[J];Journal of China Clinic Medical Imaging;2007-01
8 CHEN Li-bin, XU You-feng, CAO Yong, LU Jian, MAO Feng, DING Gao-feng (Department of Ultrasound, Ningbo No.1 Hospital, Ningbo Zhejiang 315000, China);Diagnosis of the thyroid mass with real-time sono-elastography and analysis of affecting factors[J];Journal of China Clinic Medical Imaging;2010-04
9 WANG Jia-wei.Shanxi Provincial People's Hospital,Taiyuan 030012,China;Diagnostic value of high frequency ultrasongraphy and mammography for breast malignant tumor[J];Journal of Practical Medical Techniques;2009-08
10 LI Ping,CHEN Su-ning,SONG Ye,LI Yuan (Dept.of Ultrasound,Tongji Hospital,Tongji University School of Medicine,Shanghai 200065,China);Value of real-time ultrasonic elastography in identification of breast masses[J];Journal of Tongji University(Medical Science);2010-02
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 LUO Jianwen, BAI Jing. Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing\ 100084;Finite Element Analysis in Simulations of Ultrasound Elastography[J];Beijing Biomedical Engineering;2003-02
2 Luo Yilun,Luo Hui,Xiong Yi,et al Department of Ultrasound,Shenzhen People’s Hospital,Second Affiliated Hospital,Jinan University,Shenzhen 518020 China;High Frequency Color Doppler Flow Imaging in Diagnosis and Diffe rential Diagnosis of Breast Masses:Compared with Pathology[J];Chinese Journal of Ultrasound Diagnosis;2005-09
3 LUO Jian wen,BAI Jing (Department of Biomedical Engineering,School of Medicine,Tsinghua University,Beijing 100084,China);The principle and theoretical analysis of ultrasound elastography[J];Foreign Medical Biomedical Engineering Fascicle;2003-03
4 ZHEN Jing-qin,ZHU Jin,LI Li,ZHANG Wen-yun,YIN Chun-xia,CAI Zhen-qi(Department of Ultrasound,the Third Hospital of Hebei Medical University,Shijiazhuang 050051,China);ASSESSMENT OF THYROID GLAND ULTRASONIC INTEGRATED BACKSCATTER IN HEALTH ADULTS[J];Journal of Hebei Medical University;2008-01
5 Pan Xiaoping *, Ni Zongzan. Department of Health Statistics, School of Public Health,WCUMS, Chengdu 610041;Application of Intraclass Correlation Coefficient to Reliability Assessment[J];JOURNAL OF WEST CHINA UNIVERSITY OF MEDICAL SCIENCES;1999-01
6 Zhao Jingmin,Zhou Guangde,Sun Yanling,et al.Department of Pathology,302 Hospital of PLA,Beijing 100039,China;Pathological,epidemiological and prognostic studies in 25946 patients with liver disease with liver needle biopsy[J];Medical Journal of Chinese People's Liberation Army;2008-10
7 Jiang Yanru,Qian XiaoqinDepartment of Ultrasound Sonography,the Second Affiliated Hospital of Dalian Medical University,Dalian 116011,China;The value of color ultrasound in analyzing the shape of spectral flow Doppler and blood vessel morphology of the patients with breast masses[J];Journal of Ultrasound in Clinical Medicine;2006-02
8 QI Zhi, ZHANG XuelanThe First Clinical Medical College of Lanzhou University,Lanzhou 730000,China;The application of three-dimensional ultrasonography in the diagnosis of breast cancer[J];Journal of Ultrasound in Clinical Medicine;2008-07
9 WANG Shiguang,YUE Linxian Department of ultrasound,Pepole's Hospital of Sichuan Province,Chengdu 610072, China;The application value of elastosonography in the diagnosis of thyroid nodules[J];Journal of Ultrasound in Clinical Medicine;2008-11
10 FENG Xia, LUO Bao-ming, OU Bing, YANG Hai-yun, WEN Yan-ling, ZHI Hui (Department of Ultrasound, Second Affiliated Hospital, Sun Yat-sen University, Guangzhou 510120, China);Evaluation elastic score's usefulness in the diagnosis of benign and malignant breast diseases[J];Journal of China Clinic Medical Imaging;2007-01
【Secondary Citations】
Chinese Journal Full-text Database 3 Hits
1 LIU Quan,WANG Jiu hua,SHEN Zhen zhou.Cancer Hospital MCFDU,Shanghai 20032;Intramammary Clustered Calcifications Without any Palpable Mass:Mammographic Diagnosis[J];Journal of Qilu Oncology;2000-06
2 Chen Man,Chen Weiguo,Gong XinhuanRuijin Hospital,Shanghai Second Medical UniversityShanghai200025;Application and Relevant Factors of Color DopplerFlow Imaging in Diagnosis of Breast Lesions[J];CHINESE JOURNAL OF ULTRASOUND IN MEDICINE;1999-07
3 LEI Cheng-gong,QIAO Ying-yan (Shanxi Medical University No.2 Hospital,Taiyuan 030001,China);Sonographic Identification of Breast Lumps and Application of SonoCT,Xres in It[J];Chinese Journal of Medical Imaging Technology;2003-05
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved