Optimization and Energy Saving Analysis of Deaerator Water Level Control in a 1000MW Ultra Supercritical Unit

ZHOU Hai-yan;China Datang Corporation Science and Technology Research Institute Co.,Ltd.Eastern China Branch;  
Currently,thermal power generation is still an important form of generating electricity in China.Deaerator is an important auxiliary equipment of steam turbine in the power plant,and its working condition has a direct effect on the safe and stable running of the generator.In accordance with the advanced idea of deaerator water level control,this paper analyzes the shortcomings of sole control and large energy consumption of current water level control mode and puts forward optimized water level control logic.It shows that optimization can reduce the throttle loss of valve and the frequency conversion power consumption of condensate removal pump,which gives full play to the superiority and energy saving effect of the optimized control mode.
【CateGory Index】: TM621
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 2 Hits
1 WANG Bo,YANG Jian-meng;The Analysis of Deaerator Water Level Control in Supercritical Unit[J];电站系统工程;2011-04
2 CHENG Qi-ming1,ZHENG Yong2(1.School of Electric Power and Automation Engineering,Shanghai University of Electric Power,Shanghai 200090,China;2.School of Automation,Shanghai University,Shanghai 200072,China);The Control System of Multi-variable PID Neural Network and Its Application in Deaerator Water Level Control[J];上海电力学院学报;2007-01
【Co-citations】
Chinese Journal Full-text Database 6 Hits
1 ZHOU Hai-yan;China Datang Corporation Science and Technology Research Institute Co.,Ltd.Eastern China Branch;;Optimization and Energy Saving Analysis of Deaerator Water Level Control in a 1000MW Ultra Supercritical Unit[J];安徽电气工程职业技术学院学报;2017-01
2 CHEN Zhe;CUI Yuhong;Energy Saving Engineering Technology Branch,Coal Science and Technology Research Institute Co.,Ltd.;State Key Laboratory of High Efficient Mining and Clean Utilization of Coal Resources;National Energy Technology and Equipment Laboratory of Coal Utilization and Emission Control;;Transformation of deoxidation system of industrial pulverized coal boiler based on programmable logic controller[J];洁净煤技术;2016-03
3 GU Xianqing;GAO Zhiqing;TU Pan;CHENG Xueqing;State Nuclear Power Engineering Company;Sanmen Nuclear Power Company;;Transient Calculation of Deaerator and Control Scheme of Cavitation Prevention for AP1000 Nuclear Power Plants[J];中国电力;2015-04
4 ZHU Bao;QIAN Haiping;WU Meng;CHEN Liqiang;WANG Chongru;SHENG Deren;Institute of Thermal Science and Power System,Zhejiang University;Zhejiang Electric Power Design Institute;Guodian Zhejiang Beilun No.3 Power Generation Co.,Ltd.;;Calculation Model for Transient Characteristics of Deaerator in Ultra Supercritical Unit During RB Process[J];动力工程学报;2014-09
5 WU Jie;XU Zhibin;MA Xiaoqian;The Key Laboratory of Efficient and Clean Energy Utilization of Guangdong Regular Higher Education Institutions,South China University of Technology;;Numerical simulation on water level control model for deaerators in nuclear power plants[J];热力发电;2014-03
6 CHENG Qi-ming1,DU Xu-feng1,GUO Run-qing1,ZHENG Yong1,2(1.School of Electric Power and Automation Engineering,Shanghai University of Electric Power,Shanghai 200090,China;2.College of Automation,Shanghai University,Shanghai 200072,China);The Simulation Study on PID Neural Network Decoupling Control System for Steam Drum Boiler Combustion[J];上海电力学院学报;2008-01
【Secondary Citations】
Chinese Journal Full-text Database 7 Hits
1 XIE Jian-yu~(1),HUANG Wei-jian~(2)(1.Zhuhai Power Station,Zhuhai,Guangdong 519050,China;2.Guangdong Power Test & Research Inst.,Guangzhou 510600,China);Mechanism of thermal deaeration and adjustment tactics of deaerator level control system[J];广东电力;2006-12
2 LIANG Wei-ping, ZHANG Jian-yu, YU Xi-ning, WANG Yong-jian(School of Control Science and Engineering, North China Electric Power University, Baoding 071003, China);Decoupling control of deaerator water level based on neural network[J];华北电力大学学报;2005-01
3 ;Using CCS Method to Solve the Application of Water Level Control System in Deaerator[J];中国电力;2001-06
4 ;Multivariable Fuzzy Control System of Deaerator's and Condenser's Water Levels for 200 MW and Below Thermal Power Units[J];中国电力;2001-01
5 Zhou Junfen (Zejiang Electric Power Test & Research Institute Hangzhou 310014) Wu Yongcun(Zhenhai Powr Plant Ningbo 315208) Cui Zhengwiu(Ningbuo Generation Overhaul Co. Ningbo 315208);Improvement on Level Control System for Dearator and Condenser[J];华东电力;2000-02
6 SHU Huailin (Tech. Faculty of Maintenance Eng., Guangzhou University, Guangzhou 510091);ANALYSIS OF PID NEURAL NETWORK MULTIVARIABLE CONTROL SYSTEMS[J];自动化学报;1999-01
7 Li Jiangeng(Dept. of Power Engineering, NCEPU, Baoding 071003);The Design of Water Level Control System for Deoxygenor by One Way Feedback Decorrelation[J];华北电力学院学报;1996-01
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved