A High Pressure Reducing Valve Maloperation Cause Analysis and Transformation

HE Jun-song;Jiangsu Xinhai Power Generation Co.,Ltd.;  
Recently,high pressure bypass system of 1000 MW coal-fired unit by high pressure reducing valve always doesn' t work properly,which brings bad influence to the safe operation of the coal-fired power generating units.By means of analyzing high pressure on the bypass system equipment and high pressure reducing valve bypass system control logic carefully,the corresponding reform scheme is put forward according to the actual situation.The main idea is to transform the high pressure bypass system onsite equipment(the first method is to change the high pressure reducing valve bypass system on the hard wiring,the second one is to increase high pressure bypass system pressure switch),and to optimize the bypass system of high pressure by the high pressure reducing valve control logic which improves the reliability of protecting action system.The main purpose of the technical transformation is to eliminate high pressure bypass valve on the hard wiring single-point protection function,prevent high pressure bypass valve misoperation,but not to refuse action.Adopting the above several technological transformations can solve the high pressure bypass valve misoperation fault effectively.
【CateGory Index】: TM621
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 1 Hits
1 YANG Guobao XIAO Guanghua Wu Mingzhi ( Guangdong Guohua Yuedian Taishan power Generation Co.Ltd. 529228 , China );The Application of Bypass Control System by Siemens in Guohua Taishan 1000MW Power Plants[J];神华科技;2012-04
【Co-citations】
Chinese Journal Full-text Database 2 Hits
1 HE Jun-song;Jiangsu Xinhai Power Generation Co.,Ltd.;;A High Pressure Reducing Valve Maloperation Cause Analysis and Transformation[J];安徽电气工程职业技术学院学报;2017-01
2 SONG Chao;WU Ming-zhi;WU Gong-bao;Shenhua Guangdong Guohua Taishan Power Plant;;Bypass Action During Plant-Wide Power Failure in a Power Plant[J];电力与能源;2015-01
【Secondary Citations】
Chinese Journal Full-text Database 1 Hits
1 FENG Wei-zhong (Shanghai Waigaoqiao No. 3 Power Generation Co., Ltd., Shanghai 200137, China);Functions and configuration of the bypass system for 1000 MW class coal-fired power generation units[J];中国电力;2005-08