Recognition of Chlorsulfuron Based on SPR Sensors with the Molecular Imprinted Polymer
Zhang Lulu,Cui Dafu,Cai Haoyuan,Li Hui,Sun Jianhai,Chen Xing (State Key Laboratory of Transducer Technology,Institute of Electronics,Chinese Academy of Sciences,Beijing 100190,China)
The high sensitivity single channel surface plasmon resonance(SPR) instrument and sample injection device made by IECAS were used in this research.The SPR instrument is of prism coupled structure with the incident angle of 40°-70°,the refractive index of 1.04-1.47,and the precision of the resonant angle of 0.001°.The molecular imprinted polymer(MIP)-SPR chip was made by PVC-MIP method and the chip thinkness below 200 nm was proved to have an excellent resonant angle.The MIP chip with the chlorsulfuron(CS) template has the ability for special adsorption compared with the non-MIP chip.The SPR detections for the CS concentrations of 0.1,0.2,0.5 and 1 μg/mL were carried out,and the refractive response signal of them meets a linear equation with R=0.996 4.The detection for the low-concentration CS was made repeatedly.The detection results show that the 50 ng/mL CS satisfies the requirement of the pesticide residue detection.
|
|
| Chinese Journal Full-text Database |
1 Hits
|
|
|
|
|
|
| Chinese Journal Full-text Database |
5 Hits
|
|
|
| 1 |
Chang Weibo Zheng Zheng(School of Electronic Information Engineering,Beihang University,Beijing 100191);Design of SPR sensor based on LabVIEW[J];Electronic Measurement Technology;2010-12 |
| 2 |
Sun Boshu Huang Zihao Wang Xiaoping Liu Yuling Liu Xu(State Key Laboratory for Modern Optical Instrumentation,Department of Optical Engineering andInformation Science,Zhejiang University,Hangzhou,Zhejiang 310027,China);Intensity-Modulated Surface Plasmon Resonance Array Sensor Based on Polarization Control[J];Acta Optica Sinica;2011-03 |
| 3 |
LI Hui CAI Haoyuan ZHANG Lulu CHEN Xing CUI Dafu(State Key Lab of Transducer Technology,Institute of Electronics,Chinese Academy of Sciences,Beijing,100190,China);THE STUDY OF SPR BIOSENSOR DETECTION METHOD FOR ATRAZINE[J];Environmental Chemistry;2010-05 |
| 4 |
CAI Xia,SUI Cheng-hua,LI Yan,WEI Gao-yao(Department of Applied Physics,College of Science,Zhejiang University of Technology,Hangzhou 310023,China);Surface plasma resonance experiment based on spectrometer[J];Physics Experimentation;2009-05 |
| 5 |
Du Meihong Chen Shuncong (Beijing Center of Physical and Chemical Analysis,Beijing 100089,China);The Application Situation of Scientific Instruments Made in China in the Food Safety Testing[J];Modern Scientific Instruments;2008-05 |
|
|
|
| Chinese Journal Full-text Database |
2 Hits
|
|
|
| 1 |
CHEN Yue,CUI Da-fu,CAI Hao-yuan,WANG Jun-bo,WANG Yu-jie(State Key Laboratory of Transducer Technology,Institute of Electronics,Chinese Academy of Sciences,Beijing 100080,China);Design of mini SPR biochemical sensor[J];Transducer and Microsystem Technologies;2006-12 |
| 2 |
Cui Dafu, Li Xiangmin, Cai Haoyuan, Li Yating, Zheng Zipan, Chen Xiang(Intitute of Electronics Chinese Academy of Sciences, State Key Laboratories of Transducer Technology,P.O.Box 2652,Beijing 100080,P.R.China);Development of Surface Plasmon Resonance (SPR) Biochemical Analysis Instrument[J];Modern Scientific Instruments;2001-06 |
|