Determination of electrolyte temperature when correcting reference temperature during capacity test of acid miner's lamp

JIANG Wan-chao, JIANG Li-hua, YANG Hai-bo (Henan Yuguang gold and lead group Co., ltd., Jiyuan Henan 454650)  
The capacity of lead-acid battery depends directly on the electrolyte temperature. Because the electrolyte temperature can't be measured accurately, errors often occur when the discharge time is calculated. According to the experience for many years, it is more convenient, accurate, and feasible to replace electrolyte temperature by environment temperature.