Study on Voltage-traveling-wave Based Fault Location for Transmission Network

LI Zewen1,2, YAO Jiangang1, ZENG Xiangjun2, CHU Xianghui2, ZHANG Xiaoli2(1. Hunan University, Changsha 410082,China; 2. Changsha University of Science & Technology, Changsha 410076, China)  
According to the double-terminal voltage traveling wave fault location, a new fault location algorithm based on the whole information of the transmission network is presented. When a fault occurs on one line, every substation records the arrival time of the first voltage traveling wave in the all transmission network, and the fault-tolerant analysis and fusion processing are made by the master substation, then the synthesis fault location can be done by utilizing the useful time data. Thus the accuracy of fault location still can be guaranteed even though a locating device breaks down, starts failure or records the wrong time data. The results of simulation indicate that this algorithm has the strong fault tolerance and the high fault location accuracy.
【Fund】: 国家自然科学基金资助项目(50577001);; 教育部新世纪优秀人才计划资助项目(NECT-04-0781);; 湖南省教育厅科技项目(07C088)~~
【CateGory Index】: TM76
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 4 Hits
1 ZENG Xiang-jun,CHU Xiang-hui,LI Ling,DENG Feng(School of Electrical & Information Engineering,Changsha University of Science and Technology,Changsha 410004,China);Faults location system with traveling wave for Zhuzhou power grid[J];Journal of Electric Power Science and Technology;2008-04
2 LI Zewen1,2,YAO Jiangang2,ZENG Xiangjun1,QIN Xiao'an1,CHU Xianghui1(1.Changsha University of Science & Technology,Changsha 410076,China;2.Hunan University,Changsha 410082,China);Optimal Placement of Traveling Wave Fault Location Equipment for Power Grid[J];Automation of Electric Power Systems;2009-03
3 LI Zewen1,2,YAO Jiangang1,ZENG Xiangjun2,CHU Xianghui2,DENG Feng2(1.Hunan University,Changsha 410082,China;2.Changsha University of Science & Technology,Changsha 410004,China);Traveling Wave Network Protection Method for Power Grid[J];Automation of Electric Power Systems;2009-06
4 DENG Feng1,ZENG Xiangjun1,CHEN Nan2,LI Zewen1,LI Libin3(1.Changsha University of Science and Technology,Changsha 410015,China;2.Wuhan University,Wuhan 430072,China;3.Sinohydro Engineering Bureau 8,Changsha 410015,China);A Network-adapted Traveling-wave Fault Location Method[J];Automation of Electric Power Systems;2009-19
【Citations】
Chinese Journal Full-text Database 10 Hits
1 Zeng Xiangjun1,Yin Xianggen1,Chen H ao1,Yu Chang1,Wu Jieyu1,L in Fuchang1, Zhang Zhe1,Chen Deshu1,Luo Yifang2 1 . Huazhong University of Science and Technology,Wuhan 430 0 74,China 2 . Central China Electric Power Corporation,Wuhan 430 0 77,China;STUDY ON A NEW TYPE OF INTEGRATIVE FAULT LOCATION SYSTEM FOR TRANSMISSION LINE[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-22
2 Xu Bingyin 1 ,Li Jing 1, Chen Ping 1 ,Chen Yu 1 ,Dong Xinzhou 2 ,Ge Yaozhong 3 ,P.F.Gale 4 (1.Kehui Electric Co Ltd,Zibo255031, China)(2.Tsinghua University,Beijing100084, China)( 3.Xi'an Jiaotong University, Xi'an710049, China)(4.Hath;MODERN FAULT LOCATION TECHNIQUES BASED ON FAULT GENERATED TRAVELLING WAVES AND THEIR APPLICATIONS[J];Automation of Electric Power Systems;2001-23
3 Chen Ping 1, Xu Bingyin 2, Li Jing 2, Dong Xinzhou 3, Ge Yaozhong 1 (1. Xi'an Jiaotong University, Xi'an 710049, China) (2. Shandong Kehui Electric Co Ltd, Zibo 255031, China) (3. Tsinghua University, Beijing 100084, China);MODERN TRAVELLING WAVE BASED FAULT LOCATOR AND ITS OPERATING EXPERIENCE[J];Automation of Electric Power Systems;2003-06
4 LI Zewen, ZENG Xiangjun, HUANG Zhiwei, LEI Li, MA HongJiang Changsha University of Science and Technology, Changsha 410076, China Hunan Hydro and Power Design Institute, Changsha 410007, China;Method for Correcting Errors of the GPS-clock Based on the High Precision Crystal Oscillator[J];Automation of Electric Power Systems;2006-13
5 LI Zewen ZENG Xiangjun XU Xiaojing LEI Li ZHANG Xiaoli (Changsha University of Science and Technology,Changsha 410076,China);New Fault Location Algorithm Based on Double Terminal Traveling Waves for Transmission Lines[J];Automation of Electric Power Systems;2006-15
6 Dong Xinzhou,Ge Yaozhong(Xi’an Jiaotong University);ALGORITHM FOR HIGH VOLTAGE TRANSMISSON LINE FAULT LOCATION USING ONE TERMINAL VOLTAGE AND TWO TERMINAL CURRENT[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1995-08
7 Chen Ping,Xu Bingyin(Kehui Electric Co.Ltd.,255031,Zibo,China)Ge Yaozhong(Xi'an Jiao tong University,710049,Xi'an,China)Wang Qian(Dongbao Electronic Device Co.Ltd.,255311,Zibo,China);A NOVEL METHOD FOR FAULT LOCATION OF TRANSMISSION LINES USING FAULT TRANSIENT CURRENT TRAVELLING WAVES[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-14
8 JIANG Tao,LU Yu-ping(Southeast University,Nanjing 210096,China);Study of fault locating based on single terminal travelingwaves avoiding wave speed influence[J];Electric Power Automation Equipment;2004-12
9 QIN Jian 1,CHEN Xiang xun 1, ZHENG Jian chao 1, WU Cheng qi 2 (1.Electric Power Research Institute China,Beijing 100085,China; 2.Chinese Dongbei Electric Group Corporation,Shenyang 110006,China);A NEW DOUBLE TERMINAL METHOD OF TRAVELLING WAVE FAULT LOCATION USING WAVELET TRANSFORM[J];Proceedings of the Csee;2000-08
10 ZENG Xiang-jun1, YIN Xiang-gen2, LIN Fu-chang2, LI Xiao-hua2, CHEN De-shu2 (1. Department of Electric Power, Changsha University of Electric Power, Changsha 410077, China ; 2. College of Electrical & Electronic Engineering, Huazhong University of Scie;STUDY ON FAULT LOCATION FOR TRANSMISSION LINES BASED ON THE SENSOR OF TRAVELING-WAVE[J];Proceedings of the Csee;2002-06
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 ;Fast Fault Location Technology for Power Cable Based on GPS and Double Terminals Traveling Wave Information[J];Anhui Electric Power;2008-01
2 XIAO Feng1,LI Xin-ran1,SHI Ji-yin2(1.College of Electrical & Information Engineering,Hunan University,Changsha 410082,China;2.Fujian Electrical Power Testing and Research Institute,Fuzhou 350007,China);Application of step response method in fault detection and location for neutral ineffectively earthed distribution systems[J];Journal of Electric Power Science and Technology;2008-01
3 ZENG Xiang-jun,CHU Xiang-hui,LI Ling,DENG Feng(School of Electrical & Information Engineering,Changsha University of Science and Technology,Changsha 410004,China);Faults location system with traveling wave for Zhuzhou power grid[J];Journal of Electric Power Science and Technology;2008-04
4 ZENG Xiang-jun,DENG Feng,LI Ze-wen,LI Ling,CHU Xiang-hui(School of Electrical & Information Engineering,Changsha University of Science and Technology,Changsha 410004,China);Novel network based traveling wave location algorithm with information fusion[J];Journal of Electric Power Science and Technology;2009-01
5 Mao Yuhua Ma Wenqi Ma Zhaoyan (Department of Electric Power Engineering);Fault-Location for Transmission Lines in Multiple-fed Network[J];JOURNAL OF NORTHEAST CHINA INSTITUTE OF ELECTRIC POWER ENGINEERING;1998-04
6 SANG Yaping,ZHAO Yulin(Engineering College,Northeast Agricultural University,Harbin 150030,China);Design of fault location system in power transmission line based on single-ended traveling wave[J];Journal of Northeast Agricultural University;2008-04
7 ZHANG Hao,ZHAO Wei(State Key Lab of Power Systems,Dept.of Electrical Engineering,Tsinghua University,Beijing 100084,China);The status and important role of mathematics in the field of electromagnetic measuring[J];Electrical Measurement & Instrumentation;2007-01
8 DING Jin,YUAN Zhen-hai(School of Automation Nanjing University of Technology,Nanjing 210009,China);Application of traveling wave fault location for the small neutral earthed system[J];Electrical Measurement & Instrumentation;2008-06
9 DING Jin, YUAN Zhen-hai(School of Automation, Nanjing University of Technology, Nanjing 210009, China);Study on Line Selection of 10kV Distributed Line Single-phase Earth Fault with Transient Current Traveling Wave[J];Electrical Measurement & Instrumentation;2009-04
10 Shu Hongchun Gao Feng(Yunnan Polytechnic University 650051 China) Ge Yaozhong(Xian Jiaotong University 710049 China);A Practical Fault Location Algorithm for Coupled Double Circuit Line[J];TRANSACTIONS OF CHINA ELECTROTECHNICAL SOCIETY;1999-06
China Proceedings of conference Full-text Database 9 Hits
1 HE Zhengyou, CAO Junjun, CHEN Xiaoqin, WU Xian (School of Electric Eng., Southwest Jiaotong University, Chengdu 610031, China);Development of the Power System Transient Signal Wavelet Analysis Instrument Based on TMS320F2812[A];[C];2004
2 DONG Xinzhou, BI Jianguang (Dept. of Electrical Engineering and Electronic Application, Tsinghua University, Beijing 100084, China);ANALYSIS ON TRANSIENT TRAVELING WAVE AND STUDY ON FAULT LINE SELECTION FOR DISTRIBUTION LINES[A];[C];2005
3 QIAO Feng, YU Fa-shan , ZHANG Yu-hua (Electrical Engineering Department, Jiaozuo Institute of Technology, Jiaozuo 454000, China);The Study of Fault Range Finding for Transmission Line Based on Traveling Wave Method[A];[C];2004
4 ;Travelling Wave Fault Alalysis System of Power System Based On DS80C320[A];[C];2007
5 JI Tao SUN Tong-jing XIONG Li-xin(1.School of Control Science and Engineering,Shandong University,Jinan 250061,China;2.Zibo Kehni Electric Co.,Ltd.,Zibo 255087,China);Fault location technique and its applications based on travelling waves in transmission line[A];[C];2005
6 (DANG Xiao-qiang~1,LIU Jun-yong~2,CHEN Yun-liang~1,LEI Xia~(2,3),ZHANG Li~(2,3),TANG Guo-dong~2,PENG Xiao-dong~1) (1.College of Water Resource and Hydroelectric Engineering,Sichuan University,Chengdu 610065,China,2.College of Electrical Engineering and Information,Sichuan University,Chengdu 610065,China,3.College of Electrical Engineering and Information,Xihua University,Chengdu 610039,China);Study of traveling waves in main electrical equipments-for fault location[A];[C];2008
7 (DANG Xiao-qiang~1,LEI Xia~(2,3),LIU Jun-yong~2,CHEN Yun-liang~1,ZHANG Li~(2,3),TANG Guo-dong~2,PENG Xiao-dong~1) (1.College of Water Resource and Hydroelectric Engineering,Sichuan University,Chengdu 610065,China,2.College of Electrical Engineering and Information,Sichuan University,Chengdu 610065,China,.3.College of Electrical Engineering and Information,Xihua University,Chengdu 610039,China);Study of traveling waves in main electrical equipments-technique implement[A];[C];2008
8 DAI Feng-long DENG Ben-zai Changsha university of science and technology,410076;A study of fault distance measurement with traveling wave for Power cable based on wavelets transform[A];[C];2008
9 ;接触网上行波信号提取的Matlab仿真[A];[C];2006
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 XU Yu-qin,LIU Li-hua,ZHANG Li(College of Electrical Engineering,Huabei University of Electric Power,Baoding 071003,China);Capacitor current compensating approach for current differential protection of ultra-high voltage transmission line[J];Journal of Electric Power Science and Technology;2007-02
2 YANG Chang-hong,LIU Cheng-zhi,CHEN Qing-hua(College of electrical engineering,Southwest Jiaotong University,Chengdu 610031,China);Research on the ability of ultra-high voltage transmission line distance protection standing fault resistance influence[J];Journal of Electric Power Science and Technology;2007-03
3 Li Tianyun Zhao Yan Ji Xiaohui Li Nan (Northeast of China Electric Power Institute Jilin 132012 China);Application of HHT Method for Analysis of Fault Signal in Electric Power System[J];Transactions of China Electrotechnical Society;2005-06
4 ZHU You-chan,DOU Bing-lin(Center of Information and Network Management,North China Electric Power University,Baoding 071003,China);Network fault location algorithm based on dependency graphs[J];Journal of Dalian University of Technology;2005-S1
5 Xiao Donghui, Liu Pei, Cheng Shijie (Huazhong University of Science &. Technology, Wuhan);SURVEY OF FAULT LOCATION PROBLEM ON OVERHEAD TRANSMISSION LINES[J];Automation of Electric Power Systems;1993-08
6 Zeng Xo'angjun. YI'n Xo'anggen, Chen Deshu, Lin Fuchang, Wei Feng(Huazhong University of Science and Technology, 430074, Wuhan. China)Zou Jianming (Central China Power Group. 430077, Wuhan, China);GPS TRAVELLING WAVE FAULT LOCATION SYSTEMS FOR TRANSMISSION NETWORK[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-10
7 Dong Xingli. Dong Xinzhou, Zhang Yancang. Guo Xiaojun. Ge Yaozhong(1. Xi'an Jiaotong University. Xi'an 710049, China)(2. Tsinghua University. Beijing 100084. China)(3. Guodian Naming AutomaTion Co Ltd. Naming 210003. China);DIRECTIONAL PROTECTIVE RELAYING BASED ON POLARITY COMPARISONOF TRAVELLING WAVE BY USING WAVELET TRANSFORM[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-14
8 Liu Ye,Wang Caitang,Su Yanmin,Zhang Yun,Zou Jianlong Xi'an Jiaotong U niversity,Xi'an 710 0 49,China;NEW DIRECTION OF STUDY OF OPTICAL CURRENT TRANSDUCER USED IN POWER SYSTEM[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-17
9 Zeng Xiangjun1,Yin Xianggen1,Chen H ao1,Yu Chang1,Wu Jieyu1,L in Fuchang1, Zhang Zhe1,Chen Deshu1,Luo Yifang2 1 . Huazhong University of Science and Technology,Wuhan 430 0 74,China 2 . Central China Electric Power Corporation,Wuhan 430 0 77,China;STUDY ON A NEW TYPE OF INTEGRATIVE FAULT LOCATION SYSTEM FOR TRANSMISSION LINE[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-22
10 Zou Jianlong,L iu Ye,Wang Caitang,Zhang Yun,Wei Zhaobi,Wang Feng Xi'an Jiaotong U niversity,Xi'an 710 0 49,China;DEVELOPMENT OF STUDY OF OPTICAL VOLTAGE TRANSDUCER USED IN POWER SYSTEM[J];Automation of Electric Power Systems;2001-09
【Secondary References】
Chinese Journal Full-text Database 2 Hits
1 ZENG Xiang-jun,DENG Feng,LI Ze-wen,LI Ling,CHU Xiang-hui(School of Electrical & Information Engineering,Changsha University of Science and Technology,Changsha 410004,China);Novel network based traveling wave location algorithm with information fusion[J];Journal of Electric Power Science and Technology;2009-01
2 HUANG Xuyong1,2,ZHANG Wenkui2,LIU Pei2(1.Yunnan Electrical Power Test & Research Institute,Kunming 650127,China;2.Huazhong University of Science and Technology,Wuhan 430074,China);Optimal placement of travelling wave fault locating equipment and its improved algorithm[J];Electric Power Automation Equipment;2010-01
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 Dong Xinzhou Liu Jianzheng(Qinghua University 100084 China) Yu Xuewen(Guodian Nanjing Automation Co Ltd 210003 China);Fault Characteristics and Wavelets Analysis of the Transient Voltage Travelling Waves[J];Transactions of China Electrotechnical Society;2001-03
2 Qin Jian Chen Xiangxun Zheng Jianchao(Electric Power Research Institute,Ministry of Electric Power);Requirement of Applying Continuous Wavelet Transform[J];TRANSACTIONS OF CHINA ELECTROTECHNICAL SOCIETY;1998-05
3 Shu Hongchun; Chen Xueyun; Xu Chengbin (Harbin Institute of Technology, 150001. Harbin. China);A PRACTICAL FAULT LOCATION ALGORITHM FOR MULTI-TERMINAL TRANSMISSION LINES WITH RADIAL STRUCTURE[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1998-02
4 Dong Xinzhou; He Jiali (Tianjin University. 300072. Tianjin. China )Ge Yaozhong (Xi'an Jiaotong University. 710049. Xi'an. China)Xu Bingyin (Kehui Electric Co. Ltd.. 255031. Zibo. China);RESEARCH OF FAULT PHASE SELECTION WITH TRANSIENT CURRENT TRAVELLING WAVES AND WAVELET TRANSFORM Part One Theoretical Basis[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1998-12
5 Zeng Xo'angjun. YI'n Xo'anggen, Chen Deshu, Lin Fuchang, Wei Feng(Huazhong University of Science and Technology, 430074, Wuhan. China)Zou Jianming (Central China Power Group. 430077, Wuhan, China);GPS TRAVELLING WAVE FAULT LOCATION SYSTEMS FOR TRANSMISSION NETWORK[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;1999-10
6 Gong Qingwu1 ,Liu Meiguan2 ,Zuo Kefeng1 ,Zhang Chengxue1 ,Li Xiaolu1 1.Wuhan University of Hydraulic and Electric Engineering,Wuhan 430 0 72 ,China 2 .Changsha Power Supply Bureau,Changsha410 0 0 7,China;ANTI-JAMMING METHODSFOR PULSE PER SECOND SIGNAL IN SYNCHRONIZED SAMPLING UNIT BASED ON GPS[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-01
7 Zeng Xiangjun1,Yin Xianggen1,Chen H ao1,Yu Chang1,Wu Jieyu1,L in Fuchang1, Zhang Zhe1,Chen Deshu1,Luo Yifang2 1 . Huazhong University of Science and Technology,Wuhan 430 0 74,China 2 . Central China Electric Power Corporation,Wuhan 430 0 77,China;STUDY ON A NEW TYPE OF INTEGRATIVE FAULT LOCATION SYSTEM FOR TRANSMISSION LINE[J];AUTOMATION OF ELECTRIC POWER SYSTEMS;2000-22
8 Xu Bingyin 1 ,Li Jing 1, Chen Ping 1 ,Chen Yu 1 ,Dong Xinzhou 2 ,Ge Yaozhong 3 ,P.F.Gale 4 (1.Kehui Electric Co Ltd,Zibo255031, China)(2.Tsinghua University,Beijing100084, China)( 3.Xi'an Jiaotong University, Xi'an710049, China)(4.Hath;MODERN FAULT LOCATION TECHNIQUES BASED ON FAULT GENERATED TRAVELLING WAVES AND THEIR APPLICATIONS[J];Automation of Electric Power Systems;2001-23
9 Chen Ping 1, Xu Bingyin 2, Li Jing 2, Dong Xinzhou 3, Ge Yaozhong 1 (1. Xi'an Jiaotong University, Xi'an 710049, China) (2. Shandong Kehui Electric Co Ltd, Zibo 255031, China) (3. Tsinghua University, Beijing 100084, China);MODERN TRAVELLING WAVE BASED FAULT LOCATOR AND ITS OPERATING EXPERIENCE[J];Automation of Electric Power Systems;2003-06
10 Zeng Xiangjun 1,2,3, Yin Xianggen 2, Lin Gan 3, Zhou Yanling 3 (1. Changsha University of Electric Power, Changsha 410077, China) (2. Huazhong University of Science and Technology, Wuhan 430074, China) (3. Xiangneng-Xvji Company, Changsha 410013, China);CLOCK OF HIGH ACCURACY IMPLEMENTED BY CRYSTAL OSCILLATOR IN SYNCHRONISM WITH GPS-CLOCK[J];Automation of Electric Power Systems;2003-08
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved