A STUDY ON HEAT REMOVAL AND STEAM-WATER CYCLE MODES IN THE REGENERATOR OF FCC UNIT

Cheng Feng;Li Xiulin Daqing Petrochemical Engineering Designing Institute Teaching Unit of Petroleum Processing  
The paper is analysing inside and outside heat removal modes andmerits and demerits of forcing and natural steam-water cycle modes fromthe development and situation of the heat removal technology in the regeneratorof FCC unit. Thus advancing excess heat is taken from the regenerator ofFCC unit's outside with steam - water natural cycle which is a satisfactoryform of taking heat.