Strand displacement amplification piezoelectric DNA sensor

JIANG Tian lun, FU Wei ling,ZHANG Bo, CHEN Ming, LIU Ming hua, ZHANG Xue, ZHAO Shu ming, YU Fan, CHEN Xiao bin (Department of Clinical Laboratories, Southwest Hospital, Third Military Medical University, Chongqing 400038, China)  
Objective To construct a strand displacement amplification (SDA) piezoelectric DNA sensor and explore its performance. Methods ①A SDA Piezoelectric DNA sensor was established by combining strand displacement amplification (SDA) with piezoelectric DNA sensor. ②the performance of the SDA piezoelectric DNA sensor was explored by using Mycobacterium tuberculosis genomic fragment IS6110 as detecting target. Results ①The signals of the SDA piezoelectric DNA sensors reached about 500 Hz; ② The time with persistent frequency falling of the sensor was dependent on the concentration of the target DNA; ③The signals caused by different concentrations of target DNA had no evident difference. Conclusion Pathogen genome DNA can be directly detected with SDA Piezo electric DNA sensor. The response time is associated with the amount of target DNA. Hence, the SDA piezoelectric DNA sensor may be used to quantitate the target DNA.
【Fund】: 国家“九五”科技攻关项目 ( 96 A2 3 0 4 0 4 );; 国家自然科学基金资助面上项目 ( 39870 831 );; 国家高技术计划生物技术领域青年基金资助项目 (“86 3”项目 ;; 全军“九五”医学科研计划资助面上项目( 98MO94 ;; 全军“十五”医学科研计划资助面上项目 ( 0 1MA1
【CateGory Index】: R197.39
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 4 Hits
1 ZHANG Bo,FU Wei ling,MAO Qiong guo,et al. (Department of Clinical Laboratories,Southwest Hospital,the Third Military Medical University,Chongqing 400038,China);Establishment and applications of the platform for detecting oscillation frequency of piezoelectric quartz crystals[J];Chongqing Medical Journal;2003-12
2 CHEN Qing-hai, FU Wei-ling, BIAN Zhi-heng, CHEN Ming, ZHANG Bo, JIANG Tian-lun, TANG Wan-li, CAI Guo-ru (Department of Clinical Laboratory, Southwest Hospital, Third Military Medical University, Chongqing 400038, China);Design of a stable system of quartz oscillation sensor in liquid phase and the test of HCMV[J];Acta Academiae Medicinae Militaris Tertiae;2003-21
3 CHEN Qing-hai, FU Wei-ling, CHEN Ming, ZHANG Bo, TANG Wan-li, JIANG Tian-lun, GONG Yan-wen, CAI guo-ru (Department of Laboratory Medicine, Southwest Hospital, the Third Military Medical University, Chongqing 400038, China);Detecting HCMV Strand Displacement Amplifications by Piezoelectric Gene Sensor: An Experimental Research[J];Chinese Journal of Nosoconmiology;2004-01
4 CHEN Bin, FU Wei-ling, JIANG Tian-lun,HUANG Jun-fu (Department of Laboratory Medicine, Southwest Hospital, the Third Military Medical University, Chongqing 400038, China);Detection of Pseudomonas aeruginosaby SDA Piezoelectric DNA Sensors Array: A Clinical Application[J];Chinese Journal of Nosoconmiology;2004-01
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 TIAN Ning, HUANG Shan, ZHANG Jian (2nd People's Hospital of Wuhu City, Anhui Province,Wuhu 241000);The progress of auto mated coagulation analyzer in method and technology[J];Anhui Medical and Pharmaceutical Journal;2001-04
2 Guo Aiyan, Wang Yinzhang, Huang Zhaojian,et al.(Department of Endocrinology,PLA General Hospital, Beijing 100853);Determination of Serum Insulin by Solid Phase Radioimmunoassay with Ab_2-immobilized Tubes[J];LABELED IMMUNOASSAYS AND CLINICAL MEDICINE;1994-02
3 Yong Guidong Guan Pingfeng(Department of Precision Instruments and Mechanology, Tsinghua University, Beijing 100084);On the Problems in investigation of Acoustic Load Sensitivityof Quartz Crystal Resonator and Related Sensors[J];Journal of Transcluction Technology;1996-04
4 YE Wei-quan 1, ZHOU Kang-yuan 1, WANG Jun 1, CHEN Xin 1, LIU Sheng 1 FU Shao-jun 2, TAO Xiao-ming 2, HUO Tong-lin 2, HONG Yi-lin 2, XU Xiang-dong 2, ZHOU Hong-jun 2 (1. Dept. of Elec. Engin. and Info. Sci., University of Science and;A study on the quartz micro-biosensors[J];JOURNAL OF TRANSDUCER TECHNOLOGY;2000-04
5 Fu Hongqiao Wen Yumei Li Ping (Department of Optoelectronic Information Engineering,Chongqing University,Chongqing 400044);Data Acquiring and Processing on Quartz Resonance Weighing Sensor[J];JOURNAL OF TRANSDUCER TECHNOLOGY;1998-05
6 ;Research Progress and Outlook of Quartz Crystal Microbalance[J];Sensor World;2000-03
7 LIU Ming hua,FU Wei ling,CHEN Ming,et al. (Department of Medical Laboratory Science,Southwest Hospital,Third Military Medical University,Chongqing 400038);Effects of temperature on hybridization efficiency in piezoelectric gene sensor arrays[J];Chongqing Medical Journal;2001-06
8 ZHANG Bo,FU Wei ling,MAO Qiong guo,et al (Department of Laboratory ,Southwest Hospital,the Third Military Medical University,Chongqing 400038,China);Experimental study of insulin piezoelectric immunosensor[J];Chongqing Medical Journal;2003-02
9 LIU Ming hua, FU Wei ling, WANG Shong lin, HUANG Qing,CHEN Ming (Department of Medical Laboratory Science, Southwest Hospital, Third Military Medical University, Chongqing 400038, China);Effects of probe concentration on hybridization efficiency of piezoelectric gene sensor arrays[J];Acta Academiae Medicine Militaris Tertiae;2001-10
10 HUANG Qing, LIU Ming hua, ZHANG Xue, HUANG Jun fu, CHEN Ming, JIANG Tian lun, ZHANG Bo, FU Wei ling (Department of Clinical Laboratories, Southwest Hospital, Third Military Medical University, Chongqing 400038, China);Design and development of a software for an quartz crystal microbalance-based gene analyzer[J];Acta Academiae Medicine Militaris Tertiae;2002-01
【Secondary References】
Chinese Journal Full-text Database 6 Hits
1 YAN Hui-hui,ZHANG Bo,FU Wei-ling,et al.(Department of Clinical Laboratory,Southwest Hospital,Third Military Medical University,Chongqing 400038,China);Effects of the probe concentration on a novel biosensor based on protein-DNA reaction[J];Chongqing Medicine;2007-20
2 ZHAO Meng, FU Wei-ling, CHEN Ming, XIA Han, LUO Yang, ZHAO Yu-hui, WANG Feng (Department of Clinical Laboratory Diagnosis, Southwest Hospital, Third Military Medical University, Chongqing 400038, China);Exponential decay regularity of frequency and endpoint determination by maximal-curvature in piezoelectric coagulation[J];Acta Academiae Medicinae Militaris Tertiae;2006-04
3 (510641,School of Bioscience and Bioengineering,South China University of Technology,Guangzhou P.R.China)Zhu Bin Wu Kai Wu Xiaoming;The application of MCU and CPLD on the frequency detection of quartz crystal DNA sensor[J];;2006-34
4 CHEN Bin, FU Wei-ling, HUANG Qing, ZHANG Xiao-bing, HUANG Jun-fu(Southwest Hospital,the Third Military Medical University,Chongqing 400038, China);Detection of Pseudomonas aeruginosa by Piezoelectric Immunosensor Microarray: An Experimental Research[J];Chinese Journal of Nosoconmiology;2005-04
5 WANG Feng~*,FU Wei-ling,XU Xue-qing,XIA Han,LUO Yang(*Southwest Hospital,the Third Military Medical University,Chongqing,400038,China);Piezoelectric Gene Biosensors for Detection of Pseudomonas aeruginosa Using Signal Amplification Method with Cationic Conjugated Polymers[J];Chinese Journal of Nosocomiology;2006-11
6 XIA Han, HUANG Jun-fu, YAO Chun-yan, WANG Feng, CHEN Ming, HUANG Qing, FU Wei-ling(Southwest Hospital, the Third Military Medical University, Chongqing 400038, China);Rapid Identification of Staphylococcus epidermidis by HRP-DAB Amplification Based Piezoelectric Quartz Crystal Microbalance DNA Sensor Array[J];Chinese Journal of Nosocomiology;2008-03
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved