Axial Heat Conduction of Interspaced Matrix Cryogenic Heat Exchangers

Shu Shuiming; Guo Fangzhong  
A metliod of heat network is useful for comouter simulating theperformance of the complicated heat exchangers.One way to improve theperformance of the heat exchangers is to reduce their axial heat conducti-ons.On the basis of heat network model of the interspaced multilayer ma-trix cryogenic heat exchangers,the effects of the axial heat conductions onthe performance of the heat exchangers have been quantitatively analyzedand the worst location of the performance deterioration due to axial heatconduction has been found.All above provide the important basis for de-signing and producing the high effectiveness heat exchangers.
【CateGory Index】: TB657.5
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【References】
Chinese Journal Full-text Database 3 Hits
1 Jiang Zhenhua Gan Zhihua Liu Huazhao Cheng Zhangzhan(Cryogenics lab, Zhejiang University, Hangzhou 310027, China);Heat loss analysis of a 20 K pulse tube cryocooler[J];Gryogenics;2005-02
2 Shu Shuiming;Zhang Bingyuan;Investigation on Interspaced Multilayer Matrix Cryogenic Heat Exchangers[J];GRYOGENICS;1994-03
3 Shu Shuiming;Computer Simulation of lnterspaced Multilayer Matrix Cryogenic Heat Exchangers[J];GRYOGENICS;1994-05
【Co-references】
Chinese Journal Full-text Database 10 Hits
1 ZHAO Lei (16 Institute of Information Industry Ministry,Hefei 230043);5W Gifford-McMahon Compressor and Its Experimental Test[J];JOURNAL OF ANHUI AGRICULTURAL UNIVERSITY;2001-04
2 Cheng Dewei; Wang Hulling; Li Jia; Zhu Yuqun (Institute of Refrigeration and Cryogenic Engineering,Huazhong Univ. of Sci. &. Tech., Wu Han 430074 );DEVELOPMENT OF SUPERCONDUCTING POWER TECHNOLOGYAND RELEVANT CRYOGENIC TECHNOLOGY[J];GRYOGENICS;1999-05
3 Gong Linghui 1) Zhang Ling 1) Xiao Liye 2) ( 1) Cryogenic Lab,Technical Institute of Physics and Chemistry,CAS,Beijing 100080) ( 2) Institute of Electrical Engineering,CAS,Beijing 100080);A SINGLE-STAGE G-M REFRIGERATOR WITH HIGH COOLING CAPACITY FOR HTS DEVICE[J];Gryogenics;2002-01
4 Cheng Zhangzhan Gan Zhihua Qiu Limin Chen Guobang(Cryogenics lab., Zhejiang University, Hangzhou 310027);PRELIMINARY EXPERIMENT ON A SINGLE-STAGE GM TYPE PULSE TUBE COOLER NEAR 20 K[J];Gryogenics;2004-03
5 Fang Zhichun 1,2 Su Xiaotao 1,2 Gong Linghui 1 Zhang Liang1(1Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, B eijing 100080) (2Graduate School of Chinese Academy of Sciences, Beijing 100039);THE EXPERIMENTAL STUDY OF HIGH PERFORMANCE SINGLE-STAGE G-M REFRIGERATOR[J];Gryogenics;2004-05
6 Shu Shuiming;Zhang Bingyuan;Investigation on Interspaced Multilayer Matrix Cryogenic Heat Exchangers[J];GRYOGENICS;1994-03
7 Mao Wenping; Li Shimo;Rare Earth Magnetic Material Applied to the VM Cryocooler[J];GRYOGENICS;1995-03
8 Li Yourong; Wu Shuangying(Department of Heat power Engineering,Chongqing University,630044);The Analysis of Exergy Efficiency in the Low Temperature Heat Exchanger[J];GRYOGENICS;1995-06
9 Wang li Xu Xiangdong Zhang liang (Cryogenic Laboratory,Chinese Academy of Sciences,P O Box 2711,Beijing 100080);SIMULATION OF THE DYNAMIC PROGRESS IN THE HIGH TEMPERATURE REGENERATOR OF A GM REFRIGERATOR[J];GRYOGENICS;1998-02
10 Zhang Zhiyong Chen Liang Zhang Liang (Cryogenic Laboratory,Chinese Academy of Sciences,Beijing 100080);INVESTIGATION OF THE OPERATING PARAMETERS INFLUENCE ON THE PERFORMANCE OF A TWOSTAGE GM CRYOCOOLER[J];GRYOGENICS;1998-05