Structure and Characteristics of Wet Cooling Tower Fill in Coal-fired Unit

PAN Wen-rui,REN Jian-xing,WENG Jian-hua (School of Thermal Power and Environmental Engineering,Shanghai University of Electric Power,Shanghai 200090,China)  
The wet cooling tower is one of the most important components of coal-fired units.There are three forms in surface shape of conventional packing,namely,drip-type,thin-film type and bit thin film.Different structural characteristics of the tri-type fillers and the matching tower structure are introduced to analyze the influence that the structure type,water drenching density and other factors of fillers have on the outlet water temperature of cooling tower and economical efficiency of the power plant unit.
【CateGory Index】: TK229.6
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 10 Hits
1 JING Changcai(Guohua Electric Power Co., Ltd, Beijing, 100025, China);Analysis and Application of the Properties of the Ceramic Spray Packing for Cooling Tower[J];Power Station Auxiliary Equipment;2005-01
2 GAO Fu-dong, SUN Feng-zhong, WANG Kai;Development and Study of Cooling Tower Fill in Power Plant[J];Power System Engineering;2007-05
3 HU San-ji1, CHEN Yu-ling1, LIU Ting-xiang1, TANG Fa2(1.China Thermal Power Research Institute, Xi'an 700032, China; 2. China National Water Resources & Electric power materials & Equipment Co., Ltd Shanghai Branch, Shanghai 200063, China);Test of Thermal and Resistance Performance of Water Drenching fillers with Different Height[J];Industrial Water & Wastewater;2005-01
4 LIU Dong-Xing,ZHOU Ya-su,SHA Zhan,LI Wei School of Environmental Science & Engineering,Donghua University;Development of Cooling Tower Packing[J];Building Energy & Environment;2008-05
5 ZHOU Lan-xin1,JIANG Bo2(1 Key Laboratory of Ministry of Education of Condition Monitoring and Control for Power Plant Equipment,North China Electric Power University,Baoding 071003,China;2 Guangdong Huizhou Pinghai Power Plant,Huizhou 516363,China);Numerical Study of Crosswind Effect on wet Cooling Tower Thermal Performance[J];Turbine Technology;2009-03
6 Hu Sanji, Chen Yuling;THERMAL AND RESISTANCE PERFORMANCE ANALYSIS OF PLASTIC FILLINGS OF COOLING TOWERS[J];Thermal Power Generation;1992-04
7 WANG Kai,SUN Feng-zhong,WANG Wei;NUMERICAL ANALYSIS OF AERODYNAMIC FIELD IN WET TYPE NATURAL-DRAFT COOLING TOWER[J];Thermal Power Generation;2006-10
8 ZHAO Yuan-bin,SUN Feng-zhong,WANG Kai,GAO Ming(College of Energy Source and Power Engineering,Shandong University,Jinan 250061,China);Three dimensional numerical analyses of heat and mass transfer in a wet cooling tower[J];Journal of Shandong University(Engineering Science);2008-05
9 Zhao Zhen-guo Shi Jin-ling Chen Xian-song(Department of Cooling Water institute of Water Conservancy andHydroelectric Power Research(IWHR) , Beijing 100044);Study on the Airflow Resistance in Natural Draft Cooling Towers[J];Journal of Hydrodynamics;1993-04
10 Zhao Zhen-guo(Water Conservancy and Hydroelectric Power Research,Beijing 100044);A New Thermo-characteristic Formula for the Packing of Cooling Tower and It's use[J];Journal of Hydrodynamics;1996-06
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 BI Qing sheng, et al. (Dept. of Energy and Power,Changchun Institute of Technology,Changchun 130012,China);Solving measures against freezing problem of cooling towers encountered in winter[J];Journal of Changchun Institute of Technology;2002-02
2 BI Qing sheng, et al. (Dept.of Energy and Power,Changchun Institute of Technology,Changchun 130012,China);Problems existing in cooling towers of power plants and major countermeasures[J];Journal of Changchun Institute of Technology;2003-01
3 SONG Feng-ming(1,2),YIN Yu-xian2(1.School of Environment and Science &Engineering,Huazhong University of Science and Technology,Wuhan 430074,China;2.Pingdingshan Institute of Techonology, Pingdingshan 467001,China);Experimental investigation on secondary effluent treatment of sewage plant using lime-flocculation[J];Journal of Pingdingshan Institute of Technology;2006-06
4 HUANG Cheng-qun (Basic Course of Chongqing Electric Power College, Chongqing 400053);Requirements and Analyzes of the Direct Drinking Water[J];Journal of Chongqing Electric Power College;2000-04
5 HUANG Cheng-qun1 WANG Ling2(1. Chongqing Electric Power College, Chongqing 400053; 2. Guangzhou Hengyun Business Group, Guangzhou 510730);Chemical Cleaning of a Central Air-conditioner Water System[J];Journal of Chongqing Electric Power College;2005-03
6 ZHANG Fang1, WANG Hongmei1, LI Shanfeng2, LI Yuchun1(1.Dept. of Chemistry,Changsha University of Electric Power,Changsha 410077,China;2.Dept. of Chemistry,Hubei Electric Power Experimental Institute,Wuhan 430074,China);Application of Excel2000 on Engineering Data for Double-Y Axis Analysis[J];Journal of Changsha University of Electric Power(Natural Science);2003-01
7 ZHU Zhi-ping,WANG Hong-mei,ZHOU Qiong-hua (Department of chemistry and Engineering Engineering,Changsha University of Science and Technology,Changsha 410076,China);The impurity in feedwater how to affect the boiler water pH value[J];Journal of Electric Power Science and Technology;2007-01
8 ZHAO Yi-su~(1), WANG Yi~(2),MU Si-bai~3(1.RHI Refractories Dalian Co. Ltd.,Dalian 116600,China;2.College of Civil and Architectural Engineering,Dalian University,Dalian 116622,China; 3.Dalian University of Foreign Language, Dalian 116001, China);Some common problems about the cooling water system of central air condition[J];Journal of Dalian University;2005-02
9 SUN Bin-bin,SUN Xiao-yan,XU Zhi-ming(Northeast Dianli University Jilin 132012);Numerical Simulation for Heat Transfer Character of an Air Cooling Tower[J];Journal of Northeast Dianli University;2006-01
10 FANG Jin-xiang;Methods of increasing circulating water cycles of concentration in Yizhen chemical fiber thermal power plant[J];Electric Power Environmental Protection;2006-05
China Proceedings of conference Full-text Database 7 Hits
1 Cao Shunan (1.College of Power and Mechanical Engineering,Wuhan University,Wuhan 430072);A Robust Adaptive Smith-PID Control Algorithm Based on BP Neural Network for Water Quality Adjusting System in Power Plant[A];[C];2007
2 Wang Wei Hong~1 Wang Dong Ping~2 (1 College of Water Conservancy and Civil Engineering,Xinjiang Agricultural University,Uurumqi,830052; 2 Academy of Civil Engineering,Henan Province,Zhengzhou,450007);The Influence of Optimization of Rregeneration Technology Condition on The Tcchnological and Economic Indexes of Preparing Water in The Real Process of Salt Deminetion Water[A];[C];2005
3 FANG Jin-xiang (Thermal Power Plant of Yizheng Chemical Fiber Co.Lt.,Yizheng 211900 china);Acid pickling,scale andcorrosion,inhibition,sterilization and filtration to increase recirculating water concentration rate in thermal power plant[A];[C];2006
4 WU Shao-zhong Xie Ping-jia (Shenzhen zyme industry CO.,LTD.Shenzhen518031,China);Methods of reducing noise for natural ventilation cooling tower[A];[C];2007
5 GAO Ming SUN Feng-zhong SHI Yue-tao WANG Kai ZHAO Yuan-bin (Shandong University,School of Energy Source and Power Engineering,Jinan,Shandong,250061);Experimental research on variation rules of performance parameters about wet cooling tower under cross-wind conditions[A];[C];2008
6 WANG Song-ling, HU Hong-li, ZHANG Xue-lei, Dong Jun (North China Electric Power University School of Energy and Power, Baoding 071003);Numerical Simulation of Cooling Tower Outlet Water Temperature[A];[C];2005
7 Zhou Jinsong, Wang Li, Wu Jiazhou, He Xiaohong (Xi’an Jiaotong University, Xi’an 710049, Shaanxi, China);The Four Parameters Model of Cooling Tower[A];[C];2009
【Secondary Citations】
Chinese Journal Full-text Database 10 Hits
1 Yin Zheng (State Administration of Building Material Industry FRP Research and Design Institute);PRELIMINARY STUDY ON THE EFFECT OF ENVIORMENT CONDITION ON FRP COOLING TOWER’S COOLING ABILITY[J];FIBER REINFORCED PLASTICS/COMPOSITE;1997-04
2 Wei Hongqi Ju Gang (Department of Power Engineering, Southeast University, Nanjing 210096);Mathematical Model for Optimal Operation of the Piping main Scheme Circulating Water System[J];Journal of Southeast University;1998-S1
3 JING Changcai(Guohua Electric Power Co., Ltd, Beijing, 100025, China);Analysis and Application of the Properties of the Ceramic Spray Packing for Cooling Tower[J];Power Station Auxiliary Equipment;2005-01
4 JING Changcai (Beijing Electric Technology Research Center Co.,Ltd.,Guohua Corp.,Sanhe,Hebei,065201,China);Analysis of Economic Operation of the Recycling Water System in 600MW Power Unit and its Countermeasures[J];Power Station Auxiliary Equipment;2007-04
5 GAO Fu-dong, SUN Feng-zhong, WANG Kai;Development and Study of Cooling Tower Fill in Power Plant[J];Power System Engineering;2007-05
6 XIAO Deng-wen(Guangzhou Power Plant Co.,Ltd.,Guangzhou 510160,China);Analysis on Factors Affecting Performance of Condensers[J];Guangdong Electric Power;2008-04
7 Luo Yinghong (Dept of Telecommunication & Arto Contral,Lanzhou Railway Institute,Lanzhou\ 730070\ China);RESEARCH ON HOW TO SOLVE THE PROBLEM OF GETTING THE OPTIMAL COMBINATION IN GA[J];JOURNAL OF GANSU SCIENCES;1997-02
8 Ge xiao-xia Miao guo-jun Nanjing College of Electric Power;Optimum Adjustment of Circulating Pump for Generating Unit No. 3 of Huai-nan Power Plant[J];Power Station Auxiliary Equipment;1993-03
9 DONG Li-juan,ZHANG Run-pan,ZHANG Chun-fa(School of Energy and Power Engineering,North China Electric Power University,Baoding 071003,China);Effect of condenser pressure variation on unit power increment calculation[J];Journal of North China Electric Power University(Natural Science Edition);2007-01
10 HU San-ji1, CHEN Yu-ling1, LIU Ting-xiang1, TANG Fa2(1.China Thermal Power Research Institute, Xi'an 700032, China; 2. China National Water Resources & Electric power materials & Equipment Co., Ltd Shanghai Branch, Shanghai 200063, China);Test of Thermal and Resistance Performance of Water Drenching fillers with Different Height[J];Industrial Water & Wastewater;2005-01
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved