Promotive Measures for Stabalizing Combustion at Low Boiler Load

GUO Guangling,WANG Bingdong,LIU Xianhang(Xinyang Huayu Power Co. Ltd., Xinyang 464000)  
Basing on combustion stabalizing principles, the paper discusses how to optimize the way of operating pulverizing systems at low boiler load, the combustor's corresponding mode of operation, measures for boosting combustion of low quality coal and the way of supplying air, all for the purpose of improving the combustion stabalizing capability at low boiler load.
【CateGory Index】: TK223.21
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Citations】
Chinese Journal Full-text Database 2 Hits
1 Yan Wei-ping;Xu Tong-mo;XuJin-Yuan(North China institute of Electric Power);Experimental Study on The Existence of An Optimum Pulverized Coal Concentration in An Air Flow at Ignition[J];POWER ENGINEERING;1994-04
2 Chen Shi-ying;Liu Gui-su; Zeng Han-cai; Ma Yu-yi(Huazhong University of Science and Technology);Fundamentals of the Flame StabilizingQuality of U. S. CE-WR Burners[J];POWER ENGINEERING;1995-02
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 ZHANG Hong-fei (Anhui Electrical Engineering Professional Technique College, Hefei 230051, China);Experiment and Numerical Research of the Heat Difference for Large Coal-fired Boiler[J];;2004-01
2 WANG Hua, GAO Yong-jun (Wuhu Power Plant, Wuhu 241009, China);Ignition Stabilization and Controlled Measure of No Casting Oil Burn Under Low Load[J];;2005-03
3 WU Ming-quan HAN Run(Chongqing University of Science and Technology,Chongqing 400050);The Development of a VB Language Program for the Calculation of the Thermal Balance and Thermal Efficiency on Boiler[J];;2005-04
4 Chen Donglin;Wang Shuqi(Dept. of Power Eng.,Changsha Univ. of Electr. Power,Changsha 410077);ANALYSIS AND REALIZATION OF THERMOSTATIC COMBUSTION OF PULVERIZED-COAL FIRED BOILER[J];JOURNAL OF CHANGSHA UNIVERSITY OF ELECTRIC POWER(SOCIAL SCIENCE);1995-02
5 Yan Xiaozhong Ouyang Changsheng Ouyang Xuejun(Dept. of Power Eng.);Analysis of Cold Test of the WGZ75/39-6 Pulverized Coal Fired Boiler[J];JOURNAL OF CHANGSHA UNIVERSITY OF ELECTRIC POWER(NATURAL SCIENCE);1998-01
6 Xin Guohua Zhang Weihui Gu Yunxing Gao Jingping (Department of Thermal Power Engineering,Northeast China Institute of Electric Power Engineering,Jinlin city 132012);Experiment Study of Pulverized-Coal Concentrator[J];JOURNAL OF NORTHEAST CHINA INSTITUTE OF ELECTRIC POWER ENGINEERING;1997-03
7 Ni Debin Deng Yajun Chen Dayuan Yuan Jie;Air Modeling Experimental Research on the Bottom Flue of DG670/140-8 Boiler[J];Dongfang Electric Review;1998-03
8 Li Dongxiong(Taiyuan Higher Electrical College) Wu Guirong(Shengtou No.1 Power Plant);The Analysis and Measures to the Causes of Furnace Slagging in 650t/h Boiler[J];JOURNAL OF ELECTRIC POWER;2000-01
9 Jia Guozhang(Niangziguan Power Plant) Li Dongxiong(Taiyuan Higher Electrical College) Xu Shiwen(Niangziguan Power Plant)Hao Rui(Shanxi Electrical Scientific Research Institute);Study on Combustion Regulation of 410 t/h Boiler[J];JOURNAL OF ELECTRIC POWER;2000-03
10 Wu Guirong(Shentou No.1 Power Plant) Li Dongxiong(Taiyuan Higher Electrical College);Measures to Improve Regulating Performance of 200MW Boiler[J];Journal of Electric Power;2000-04
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved