Environmental Impact on Electromagnetic Radiation of 220kV Power Transmission and Distribution Project

XIE An1, SHI Yu2, ZHOU Xuan3 (1.School of Materials Science and Chemical Engineering; 2.School of Environmental Studies,China University of Geosciences,Wuhan 430074,China; 3.School of Environmental and Civil Engineering,Wuhan Institute of Technology,Wuhan 430074,China)  
Based on field investigation and monitoring,with a 220kV transmission and distribution project as the study object, environment contribution of the electromagnetic radiation to project circumjacent area was quantitatively assessed through computing mode recommended by Appendix A,B and C of Technical Specification of EIA of Electromagnetic Radiation for 500kV High Voltage Transmission Project (HJ/T24-1998)after the project was put into production. By comparing the project with another similar project which shares the same voltage scale and volume as well as lead mode,some conclusions and corresponding suggestions for electromagnetic radiation were proposed.
【CateGory Index】: X820.3
Download(CAJ format) Download(PDF format)
CAJViewer7.0 supports all the CNKI file formats; AdobeReader only supports the PDF format.
【Co-citations】
Chinese Journal Full-text Database 10 Hits
1 WANG Qun, LI Yong-qin, CHEN Jing, ZHOU Mei-ling (College of Material Science and Engineering, Beijing University of Technology, Beijing 100022, China);Analysis and Assessment of Electromagnetic Field Under 110 kV High Voltage Transmission Lines[J];Journal of Beijing Polytechnic University;2005-03
2 SUN Bo1, SUN Tongjing1, XUE Yongduan2,3, XU Bingyin2,3, JI Tao4(1. Shandong University, Jinan 250061, China; 2. Shandong Kehui Electric Co Ltd, Zibo 255087, China; 3. Shandong University of Technology, Zibo 255049, China; 4. Weifang University, Weifang 261061, China);Single Phase to Ground Fault Section Location Based on Transient Signals in Non-solidly Earthed Network[J];Automation of Electric Power Systems;2008-03
3 SUN Bo1,XUE Yongduan2,3,SUN Tongjing1,XU Bingyin2,3,WANG Tao2,JI Tao4(1.Shandong University,Jinan 250061,China;2.Shandong Kehui Electric Co Ltd,Zibo 255087,China;3.Shandong University of Technology,Zibo 255049,China;4.Weifang University,Weifang 261061,China);A Fault Current Measurement Method for Single Phase Grounding of Non-solidly Earthed Overhead Lines[J];Automation of Electric Power Systems;2008-09
4 SUN Bo1,SUN Tongjing1,XU Bingyin2,XUE Yongduan2,WANG Tao2(1.Shandong University,Jinan 250061,China;2.Shandong Kehui Electric Company Limited,Zibo 255087,China);A Zero-module Voltage Measurement Method for Single Phase to Ground Fault of Non-solidly Earthed Overhead Lines[J];Automation of Electric Power Systems;2009-06
5 LIU Jun le (Zhongshan Electric Power Bureau, Zhongshan 528400, China);Discussion about electric erode of ADSS cabel and protection[J];Telecommunications For Electric Power System;2001-06
6 CUI Xiang~1,WANG Fu-chang~2,LU Tie-bing~1,ZHONG Cheng~2,WU Mao-lin~1,ZHANG Bo~1 (1. North China Electric Power University,Baoding 071003,China; 2. Electric Power Dispatching & Communication Centre,Shijiazhuang 050021,China);Applying three-dimensional electric field computational method to locate the ADSS optical fiber cable suspended on high voltage transmission line towers[J];Telecommunications For Electric Power System;2004-02
7 YAN Deng-jun1,Li Wei1,WANG Gui-qin2,ZHAO Ji-wan2(1.Electrical Engineering Department,Hohai University,Nanjing 210098,China;2.Physics Department,Nanjing University,Nanjing 210008,China);Progress in Bio-Electromagnetism Research[J];Journal of Electrical & Electronic Education;2007-03
8 ZHANG Bo, CUI Xiang, LU Tie-bing, LI Lin, ZHAO Zhi-bin (North China Electric Power University, Baoding 071003, Hebei Province, China);A NUMERICAL METHOD TO CALCULATE THREE DIMENSIONAL ELECTRIC FIELD OF EHV TRANSMISSION LINE NEAR TOWERS[J];Power System Technology;2003-07
9 XIAO Dong-ping1,HE Wei1,XIE Peng-ju1,KANG Peng2,LIU Hua-lin2,ZHANG Zhan-long1 (1.Key Laboratory of High Voltage and Electrical New Technology (Chongqing University),Ministry of Education, Shapingba District,Chongqing 400030,China;2.Guizhou Electric Power Testing Research Institute, Guiyang 550002,Guizhou Province,China);Study on Corona Discharge Characteristic of High Voltage Transmission Line and Calculation of Its Electromagnetic Radiation Field[J];Power System Technology;2007-21
10 Wang Lizhi (First Surveying and Designing Institute, Ministry of Railway Lanzhou 730000,China);Preliminary Introduction to Interference Protection Measures for Crossing of 500 kV Transmission Lines over Railroad[J];POWER SYSTEM TECHNOLOGY;1994-04
【Secondary Citations】
Chinese Journal Full-text Database 3 Hits
1 LI Xiang_zhen,LIU Jia_liang,ZHAO Bing_zhen,WANG Li_ping(China Electric Power Research Institute,Beijing 100085,China);A study on the PLC system performance and its electromagnetic radiating emission[J];Telecommunications For Electric Power System;2003-04
2 SUN Xin-ru,WANG Qiao-chen (State Grid Telecom Center,Beijing 100761,China);Research on the electromagnetic radiation in PLC technology[J];Telecommunications For Electric Power System;2004-04
3 ;Treat scientifically the electromagnetism radiation problem on the electric facilities[J];Enviornment;2005-09
©2006 Tsinghua Tongfang Knowledge Network Technology Co., Ltd.(Beijing)(TTKN) All rights reserved